10
14
Sensitivity: >0.5V RMS while
≤
1 MHz ;
Sensitivity: >3V RMS while >1 MHz;
Input Protection: 250V DC or 250V AC RMS.
Range
Resolution
Accuracy
9.999Hz 0.001Hz
99.99Hz 0.01Hz
999.9 Hz 0.1Hz
9.999KHz 1 Hz
±1.0% of rdg ± 5 dgts
99.99kHz 10Hz
999.9kHz 100Hz
9.999MHz 1kHz
10.00MHz 10KHz
4.8. FREQUENCY (ELECTRONIC)
Range
Resolution
Accuracy
0.1%
~
99.9%
0.1%
±1.2% of rdg ± 2 dgts
4.9. DUTY CYCLE
Pulse width: > 100us, <100ms;
Frequency width: 5Hz - 150kHz
Overload protection: 250V DC or AC RMS.
Range
Resolution
Accuracy
10.00-1kHz
0.01Hz
±0.5% of rdg ± 5 digits
4.10. FREQUENCY (ELECTRICAL)
Sensitivity: ACV Range (>6% Range); 6000μ/600.0mN 10.00A Range
(>6% Range); 600.0μ/60.00m/6.000A (>60% Range).
Range
Resolution
Accuracy
1mA typical/Open 1mV
±10% of rdg ± 5 digits
digits MAX.3.2V
4.11. DIODE TEST
Open circuit voltage: MAX. 3.2V DC
Overload protection: 250V DC or AC RMS.
4.13. ACCESSORIES
Included accessories - Standard Red/Black lead set with test probes
4.12. AUDIBLE CONTINUITY
Audible threshold: Less than 50Ω Test current MAX. 1.5mA
Overload protection: 250V DC or AC RMS.
Содержание MT1877IV
Страница 1: ...INSTRUCTION MANUAL 1000V AC DC TRMS MULTIMETER IV MT1877...
Страница 2: ...2...