Majestic Vermont Castings Chateau DVT38S2 Скачать руководство пользователя страница 1

Installation Instructions and

Homeowner’s Manual

INSTALLER:  DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE

Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electric switch;

• Do not use any phone in your

building.

• Immediately call your gas supplier

from your neighbor's phone. Follow
the gas suppliers instructions.

• If you cannot reach your gas

supplier call the fire department.

INSTALLER/CONSUMER

SAFETY INFORMATION

Chateau

Direct Vent Decorative
Gas Appliance

Model:  DVT38S2

C E RT I F I E D

DESIGN

CER

TIFIE D

20007172  7/04  Rev.1

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

CFM Specialty Home Products

Содержание Vermont Castings Chateau DVT38S2

Страница 1: ...service must be performed by a qualified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch Do not use any pho...

Страница 2: ...ation Location 10 General Information Assembling Vent Pipes 11 SK8 Venting Pipes 11 Restrictor Plate Guide 12 Horizontal Termination 12 Vertical Termination 12 Sidewall Applications 12 Sidewall Instal...

Страница 3: ...istmas stockings or decorations be hung on or around the fireplace 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be used in this fireplace 10 The flow of combustion...

Страница 4: ...6mm 44 1121mm 37 962mm 5 143mm 10 270mm 8 203mm 3 98mm 3 76mm 1 25mm When framing unit on outside wall flush with the wall a 1 4 6mm clearance must be allowed on both sides and top of surround Sides a...

Страница 5: ...o the distance between the mantel leg if fitted and the fireplace For the correct mounting height and widths refer to Figs 3a and 3b the following Mantel Charts Noncombustible mantels and legs may be...

Страница 6: ...ide of the outer casing 6 To secure the valve box assembly to the framing members open the box door remove extension knob s remove the valve cover by removing the two 2 screws securing the valve cover...

Страница 7: ...2 copper tubing or 1 2 gas tight Some municipalities have additional local codes it is always best to consult your local authority and the CSA B149 1 installation codes For USA installations consult t...

Страница 8: ...is located in the valve box assembly If desired a wall switch may be used Installation of the remote ON OFF switch on electronic ignition units 1 The valve box is equipped with two knockouts at the to...

Страница 9: ...ion hood Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent termi nation area after snow falls and clear to prevent accidental blockage of venting syst...

Страница 10: ...rance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btu...

Страница 11: ...erature metal adhesive tape that meets the requirements of F A R 25 853 a High temperature sealant milpack or stove cement of 550 F or higher could be used instead The joints of The outer pipe fresh a...

Страница 12: ...4 35 36 37 38 39 40 May use up to three 3 90 elbows but must not have two 2 consecutive 90 elbows in horizontal plane Unacceptable venting configuration FP1359 Fig 14 Horizontal vent termination windo...

Страница 13: ...t length of vent pipe from the flue collar of the fireplace to the face of the outer wall Horizontal plane means no vertical rise exists on this portion of the vent assembly The maximum number of 90 e...

Страница 14: ...ce using UL approved metal adhesive tape to ensure the joints are sealed Attach an appropriate length of vent pipe to the fireplace Follow with the installation of the inner and outer elbow tape elbow...

Страница 15: ...ass Facing Outside CAUTION Unit must be installed with stationary glass facing outside Control panel assembly will be located on the left side of the unit when facing the unit form inside house Failur...

Страница 16: ...heck that the vent pipes overlap the collars by 2 50mm Secure the termination to the wall with screws provided and caulk Installing the 38S2VDK Door When installing the DVT38S2 on an outside wall the...

Страница 17: ...1 Figure 37 for restrictor plate installation For vertical venting configurations that include a minimum vertical rise of 12 3 7m and a maximum horizontal offset of 10 3m the 4 restrictor plate suppli...

Страница 18: ...t 12 3 7m Up to two 2 30 or 45 elbows may be used within the horizontal run For each 30 or 45 elbow used on the horizontal level the maximum horizontal length must be reduced by 18 457mm Example Maxim...

Страница 19: ...ceiling above and mark position 3 Cut opening equal to 14 x 14 368mm x 368mm 4 Proceed to plumb for additional openings through the roof In all cases the opening must provide a minimum of 1 38mm clear...

Страница 20: ...act with AIS SK the chimney system Chimney Support Used to support chimney for each of 30 vertical SKCS8 height and 6 of angled chimney run Round Top Termination Top used to terminate chimney at roof...

Страница 21: ...or three times during each operating season depending on the environment in the house Clean the glass after the first two weeks of operation The use of any non approved replacement glass will void all...

Страница 22: ...ory Back Hearth Refractory Right Hearth 4 Place the right hearth refractory on the opposite side of the pilot fresh air opening side with the cut out material closer to the burner housing side 5 Insta...

Страница 23: ...will still be treated left right as you face the unit NOTE It is very critical to complete the next steps with the valve box assembly on the left as you face the unit The performance of the unit may...

Страница 24: ...e Temperature Adjustment RN RP EN EP Models For units equipped with HI LO valves the flame adjustment is accomplished by rotating the HI LO adjustment knob located near the center of the gas control v...

Страница 25: ...or gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric swit...

Страница 26: ...n or turn by hand do not try to repair it call a qualified service technician Force or attempting repair may result in a fire or explosion D Do not use this appliance if any part has been under water...

Страница 27: ...r assembly utilizes both a thermocouple and a thermopile The thermo couple operates the main valve operation On and Off Clean and or adjust pilot for maximum flame impingement on thermopile and thermo...

Страница 28: ...ply Tubing And Pressures Are Good And Pilot Burner Orifice Is Not Blocked Check Electrical Connections Between Module And Pilot Operator On Gas Control Check For 24vac Across Pv mvpv Terminals On Modu...

Страница 29: ...effectur les travaux est responsible de l installation de cette trousse L installation n est pas termin e tant que le fonctionnement de l appareil converti n a pas t v rifi selon la notice du fabrican...

Страница 30: ...positioned and install the new HI LO pressure regulator assem bly to the valve using the new screws E supplied with the kit Tighten the screws securely Ref torque in lb Fig 52 15 Install the enclosed...

Страница 31: ...Part Tube Part Tube Part Min Max DVT38S2RP EP 37 20007348 37 20007348 53 20007347 53 20007347 45 500 56 000 Table 1 Injector Orifice Size Matrix Conversion to LP Kir Burner 20007618 Burner Housing Bu...

Страница 32: ...proper operation it is imperative that the pilot and burner s flame characteristics are steady not lifting or floating Typically the top 3 8 to 1 2 of the thermopile sensing electrode should be engulf...

Страница 33: ...ucts at any time without notice DVT38S2 Decorative Gas Appliance 6081 1a 1c 2 1b 2 1e 1f 1 2 3 4 6 7 8 9a b 10a b 11a b 12a b H I LO O F F O N OFF P I L O T O F F E A P I L O T THTP TP TH 12c d 13a b...

Страница 34: ...ssembly 20005884 7b Burner Tube Assembly Pilot Side 20006879 8 Manifold Tube Assembly 20007069 9a Burner Housing Orifice 55 Natural 30000333 9b Burner Housing Orifice 37 LP 20007348 10a Burner Housing...

Страница 35: ...10000165 23 Pilot Indicator 20005908 24 Ignitor Module 20005909 25 Pilot Indicator Plug 20006250 26 Switch Rocker 53606 27 Spark Cable Connection 20005807 28a Outer Pipe Aluminum Foil Tape 20006169 2...

Страница 36: ...use the surround mantel mentioned above it is extremely critical to meet the dimensions provided especially if the mantel is not available at the time of framing NOTE In the event the mantel is not a...

Страница 37: ...pon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provision...

Страница 38: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: