background image

1

Majestic  •  TRILLIANT25IN, TRILLIANT30IN, TRILLIANT35IN Installation Manual  •  2571-980 Rev. B  •  5/23

Installation Manual

Installation and Appliance Setup

NOTICE: DO NOT

 discard this manual!

This appliance may be installed as an OEM 

installation in manufactured home (USA 

only) or mobile home and must be installed 

in accordance with the manufacturer’s 

instructions and the 

Manufactured Home 

Construction and Safety Standard,

 

Title 24 

CFR, Part 3280 

in the United States, or the 

Standard for Installation in Mobile Homes, 

CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 

of gas indicated on the rating plate. This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.

• 

DO NOT

 store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death, or 

property damage. 

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A  barrier  designed  to  reduce  the  risk  of 

burns from the hot viewing glass is provided 

with this appliance and must be installed for 

the  protection  of  children  and  other  at-risk 

individuals.

CAUTION! Risk of Fire! 

DO NOT store instruction manuals inside fireplace cavity. High temperatures 

could cause a fire.

 

INSTALLER: Leave this manual with the appliance, not inside the appliance. 

CONSUMER: Retain this manual for future reference. Do not store inside the appliance 

Models: 
TRILLIANT25IN

TRILLIANT30IN

TRILLIANT35IN

Содержание TRILLIANT25IN

Страница 1: ...uch any electrical switch DO NOT use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure...

Страница 2: ...7 G Installing Termination Cap 28 6 Electrical Information A General Information 29 B Wiring Requirements 30 C Installation Service for Fan 31 D Installation Service for Halogens 32 7 Gas Information A Fuel Conversion 33 B Gas Pressure 34 C Gas Connection 34 D High Altitude Installations 35 E Air Shutter Setting 35 F Service Replace Appliance Gas Valve 35 8 Finishing A Mantel Wall Projections Hear...

Страница 3: ...liance for fuel type ___________________________ Was a conversion performed ___________________________ Leak check performed and inlet pressure verified ___________________________ Verified proper air shutter setting for installation type ___________________________ Finishing Section 8 Combustible materials not installed in non combustible areas ___________________________ Verified all clearances ...

Страница 4: ... as primary heat in residential heating calculations NOTICE This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada B Glass Specifications This appliance is equipped with ceramic glass Replace glass only with ceramic glass Please contact yo...

Страница 5: ...nsert Ensure chimney is constructed of non combustible materials Ensure chimney is clean and in good working order Ensure that all chimney cleanouts fit properly to prevent air leakage into chimney Ensure combustible mantel and surround clearances comply with insert requirements Ensure all joints are properly engaged and the chimney is properly secured Determine minimum fireplace size See Section ...

Страница 6: ...e tool can be stored in appliance manual bag Multi purpose tool can be stored behind the surround Multi purpose tool can be stored behind the appliance front Multi Purpose Tool Shipping Location Multi Purpose Tool Storage Options NOTE This is not an option for all Inside Fit INFIT fronts Remove multi purpose tool by cutting and discarding zip tie See Figure 2 3 for multi purpose tool storage See F...

Страница 7: ...nder water Call a qualified service technician to inspect the appliance and to replace any part of the control system and or gas control which has been under water C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Pliers Hammer Phillips screwdriver Voltmeter Electric drill and bits 1 4 in Gloves Safety gl...

Страница 8: ...99 24 5 8 626 B 26 1 8 664 31 1 8 791 36 1 8 918 C 22 1 2 572 27 1 2 699 32 1 2 826 D 12 7 16 316 15 15 16 405 19 3 8 492 E 17 1 16 433 20 3 4 527 24 610 F 16 5 8 422 20 1 8 511 23 5 8 600 G 14 1 2 368 14 1 2 369 14 1 2 368 H 7 5 16 186 9 13 16 249 12 5 16 313 I 15 381 18 15 16 481 21 7 16 545 F K J GAS LINE ACCESS C D E R I A H B G O N P Q ELECTRICAL ACCESS L M MODEL DIMENSIONS Location 25 in 30 ...

Страница 9: ...BARRIER FRONTS CLEAN SCREEN A B C D E F G TRILLIANT25IN CSFI25 in 27 3 8 15 1 8 3 1 2 31 20 19 1 2 1 2 mm 695 384 89 787 508 495 13 TRILLIANT30IN CSFI30 in 32 3 8 18 5 8 3 1 8 36 23 1 2 23 1 2 mm 822 473 79 914 597 584 13 TRILLIANT35IN CSFI35 in 37 3 8 22 1 8 3 1 8 41 27 26 1 2 1 2 mm 949 562 79 1041 686 673 13 NOTICE 1 2 inch gap must be maintained or components will overheat ...

Страница 10: ... 1 4 36 23 1 2 23 1 2 mm 813 386 83 914 597 584 13 TRILLIANT35IN FA TRI35 in 37 19 3 16 3 1 4 41 27 26 1 2 1 2 mm 940 487 83 1041 686 673 13 F D A B C G E NOTICE 1 2 inch gap must be maintained or components will overheat IMPORTANT This fireplace requires an installed decorative barrier front to prevent direct contact with the hot viewing glass DO NOT operate the fireplace with the barrier removed...

Страница 11: ...N ARCH A B C D E F G TRILLIANT25IN TA TRI25 in 27 5 16 12 1 16 3 1 4 31 20 19 1 2 1 2 mm 694 306 83 787 508 495 13 TRILLIANT30IN TA TRI30 in 32 5 16 15 9 16 3 1 4 36 23 1 2 23 1 2 mm 821 395 83 914 597 584 13 TRILLIANT35IN TA TRI35 in 33 9 16 18 13 16 3 1 4 41 27 26 1 2 1 2 mm 852 478 83 1041 686 673 13 F D A B C G E NOTICE 1 2 inch gap must be maintained or components will overheat ...

Страница 12: ...ISSION FULL VIEW A B C D E F G TRILLIANT25IN MFV TRI25 in 26 1 4 14 1 2 3 31 1 4 20 19 1 2 1 2 mm 667 368 76 794 508 495 13 TRILLIANT30IN MFV TRI30 in 31 1 4 18 3 36 1 4 23 1 2 23 1 2 mm 794 457 76 921 597 584 13 TRILLIANT35IN MFV TRI35 in 36 1 4 21 1 2 3 41 1 4 27 26 1 2 1 2 mm 921 546 76 1048 686 673 13 F D A B C G E NOTICE 1 2 inch gap must be maintained or components will overheat ...

Страница 13: ...IT A B C D E F G TRILLIANT25IN INFIT 25 in 22 5 8 12 9 16 1 7 8 25 5 8 17 16 1 2 1 2 mm 575 319 48 651 432 420 13 TRILLIANT30IN INFIT 30 in 27 5 8 16 1 16 1 7 8 30 5 8 20 1 2 20 1 2 mm 702 408 48 778 521 508 13 TRILLIANT35IN INFIT 35 in 32 5 8 19 9 16 1 7 8 35 5 8 24 23 1 2 1 2 mm 829 497 48 905 610 597 13 F D A B C G E NOTICE 1 2 inch gap must be maintained or components will overheat ...

Страница 14: ...outer wrap a 1 4 inch airspace MUST be provided between the insert and the floor of the outer wrap Use the leveling legs to raise the insert a minimum of 1 4 inch The original fireplace may never be returned to solid fuel in this condition The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers 1 2 in NOTICE 1 2 inch gap must be maintai...

Страница 15: ...Note If exhaust collar on insert and fireplace damper do not line up add 4 inches 102 mm to minimum fireplace height for bends in vent pipe Custom Surrounds Custom surrounds are available See your dealer for information Standard surrounds are 3 4 inches deep Custom surrounds are available up to 3 inches deep A 3 inch deep surround would reduce the unit opening depth E by 2 1 4 inches 3 in 3 4 in 2...

Страница 16: ...nd or finishing materials must never overhang into the glass opening Observe all clearances when applying combustible materials Maximum depth of wall extension is 12 inches This may be limited by the flex pipe s ability to connect to the starting collar Covering combustible materials with non combustible materials does not qualify material as non combustible WARNING Risk of Fire DO NOT apply combu...

Страница 17: ...crack does emerge adjacent to the fireplace it can be perma nently repaired by filling it with a paintable latex caulk followed by repainting Some movement of the screws used to secure the non combustible board to the appliance surround framing is expected If a blemish begins to show over a screw head sand the surface to remove the blemish and repaint Wall Extension Wall extension must be sealed t...

Страница 18: ...ING 1 4 in Gap A C L SEE TABLE 1 or 2 18 in 12 in 12 in 6 in 6 in 4 in 2 in Figure 3 16 Minimum Vertical and Maximum Horizontal Dimensions Non Combustible Mantels or Wall Projections Non Combustible 1 4 in gap SURROUND OPENING 6 in 12 in 12 in B SEE TABLE 1 or 2 Note Measurement is taken from top of the surround opening Unit Size Surround Model A B 25 in MI25 3523 17 15 16 in 6 1 16 in MI25 3726 1...

Страница 19: ...nt must be maintained See Figure 3 18 Aminimum 1 4 inch gap from the bottom of the appliance to the metal floor of the solid fuel firebox is REQUIRED See side view in Figure 3 21 Combustible flooring underneath the appliance is acceptable with a 1 4 inch gap See Figure 3 21 FLAME SENSE IGNITER TO POWER CORD 110 120 VAC FAN 110 120 VAC RF MODULE 6V TRANSFORMER PLUG I S 6 PIN IFT RC400 REMOTE CONTRO...

Страница 20: ...recommended to provide a minimum of 24 inches of clearance in front of the appliance to the vinyl floor ing OR the bottom of the appliance should be raised a minimum of 24 inches off of the floor to allow the vinyl flooring to be installed up to the wall NOTICE Clearances that do not meet the minimum guidelines could result in damage or buckling to the vinyl flooring and is done at the installer s...

Страница 21: ...ection 7 It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs D Fireplace Conversion Notice The fireplace conversion notice is included in the appliance manual bag Permanently attach the label with the follow ing warning to the inside lower back of the fireplace firebox into which...

Страница 22: ... 10 ft Maximum Vertical Run Length 50 ft CAUTION ALL vent specifications MUST be followed This product is tested and listed to these specifications Appliance performance will suffer if specifications are not followed 5 5 Installing Vent Pipe and Appliance EXHAUST AIR VENT PIPE EXHAUST STARTING COLLAR COLLAR SLIDE PLATE ASSEMBLY EXHAUST STARTING COLLAR INLET AIR STARTING COLLAR COLLAR SLIDE PLATE A...

Страница 23: ...h restrictor openings 1 2 FRONT VIEW SHOWS RESTRICTORS IN THE OPEN POSITION AND BENT AT 90º RESTRICTOR DOORS Figure 5 3 Firebox Baffle To open restrictors push the restrictor doors upward The restrictor doors should be bent at a 90 See Figure 5 3 Figure 5 2 Min Max Venting Requirement When 20 25 feet of vertical venting is used vertical restrictors will need to be adjusted See Figure 5 2 and 5 3 O...

Страница 24: ...llation INLET AIR VENT PIPE WARNING DO NOT BLOCK THIS PIPE END INLET AIR VENT PIPE EXHAUST AIR VENT PIPE OPTIONAL LINK ZC ADPB FOR USE WITH CLASS A WOODBURNING PIPE LINK DV4 30B LINKSQ DV4 30 Installation Masonry Factory Built Wood Burning Remove 18 inch x 18 inch flashing on cap by removing 3 screws Connect both the LINK ZC ADPB to Class A Pipe and the termination cap to the LINK ZC ADPB with sel...

Страница 25: ...is appliance is listed for use with LINK DV systems and components only It is permissible to extend venting above existing chimney within specified maximum ver tical limits using SLP series 6 5 8 inch gas direct vent pipe Connection is made using DV 46DVA GK LINK DV30B LINKSQ DV30 This installation may perform better and allow less cold air in filtration in negative pressure settings LINK DV430B L...

Страница 26: ...he exhaust flexible vent pipe to the exhaust starting collar on top of the appliance with three screws See Figure 5 1 For best results in cold climate be sure 3 in flex is flush and tight to the collar slide plate assembly Seal with stove cement or aluminum foil tape Do not use silicone Use 3 screws to attach the section of inlet air vent to the inlet air starting collar on the collar slide plate ...

Страница 27: ...either the termination cap inlet air collar OR terminate within chimney DO NOT allow vent to sag below connection point to appliance Install insert without surround attached into existing fireplace while pulling collar slide plate assemby forward Install gas line into hole provided on side See Figure 5 7 Secure collar slide plate assemby to appliance by securing with 8 screw See Figure 5 1 Level t...

Страница 28: ...ERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING H minimum may vary depending on regional snowfall Refer to local codes CAUTION Risk of Cuts Abrasions Flying Debris Wear protective gloves and safety glasses during instal lation Sheet metal edges are sharp For insta...

Страница 29: ... the spark ignition of the fireplace may cause intermittent non damaging interference during the lighting sequence with a TV plugged into the same circuit It is recommended that the fireplace and TV use different circuits to mitigate the interference potential If interference is occurring on the same circuit the use of surge protectors may help alleviate the interference 6 6 Electrical Information...

Страница 30: ...52 2326 130 2326 150 2326 120 2166 302 NG 2166 303 LP GFK 160A WSK 21 W 2201 024 LIGHT WIRE ASSEMBLY 2532 017 2201 150 HALOGEN BULBS X 2 NOT AN OPTION WITH 25 in MODELS 2187 198 BATTERY PACK 2326 142 2532 301 B Wiring Requirements IntelliFire Touch Ignition System Wiring WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance power cord to a switched circuit Incorrect wiring will o...

Страница 31: ...gure 6 5 Service install fan Figure 6 2 shows a wiring diagram Reinstall valve plate assembly burner assembly base pan assembly logs and appliance glass and front C Installation Service for Fan REAR COVER PLATE NOTICE Batteries should only be used as a power source in the event of an emergency power outage Batteries should not be used as a primary long term power source Battery polarity must be co...

Страница 32: ...TALL HALOGENS OPTION 1 OPTION 2 Figure 6 7 Through Valve Plate Opening Option 2 INSTALL HALOGENS D Installation Service for Halogens On units already installed removal of decorative barrier front and gas insert may be required Option 1 Detach flexible liner from top of unit if insert is installed by removing the collar slide plate screw See Figure 5 1 Remove the five screws on the rear cover plate...

Страница 33: ...ssibility Use multi purpose tool to assist with gas shutoff See Figure 7 1 The gas ball valve is in the OFF position from manufacturer WARNING Glass seal plate must be properly installed Risk of elevated component temps and carbon monoxide exposure NOTE Bottom right glass clip on 25 inch models must be removed to gain access to controls OFF POSITION TURN KNOB CLOCKWISE NOTE Use the Multi Purpose T...

Страница 34: ...performance requires proper input pressures Gas line sizing requirements will be determined in ANSI Z223 1 National Fuel Gas Code in the USA and CAN CGA B149 in Canada Pressure requirements are C Gas Connection Refer to Reference Section 3 for location of gas line access in appliance The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300 ºF continuous exp...

Страница 35: ...ty to determine proper orifice size E Air Shutter Setting Air shutter settings should be adjusted by a qualified ser vice technician at the time of installation The air shutter is set at the factory for minimum vertical vent run Adjust ing air shutter may be desired for longer vent runs See Figure 7 5 NOTICE If sooting occurs provide more air by opening the air shutter Figure 7 5 Air Shutter Air S...

Страница 36: ... TOP VIEW MANTEL LEG OR WALL PROJECTIONS SURROUND OPENING 18 in 1 4 in Gap 12 in A 6 in 12 in C L SEE TABLE 1 or 2 Figure 8 2 Minimum Vertical and Maximum Horizontal Dimensions Non Combustible 1 4 in gap SURROUND OPENING 6 in 12 in 12 in B SEE TABLE 1 or 2 Note Measurement is taken from top of the surround opening Unit Size Surround Model A B 25 in MI25 3523 17 15 16 in 6 1 16 in MI25 3726 18 15 1...

Страница 37: ...earth Material Flooring hearth material must remain below the bottom of surround Figure 8 5 Flooring Hearth Material All flooring and hearth material must remain below the bottom of the surround See Figure 8 5 Combustible flooring may be located in front of the appliance Exception no vinyl adhesive flooring See Figure 8 6 1 2 inch gap under the bottom of the front must be maintained See Figure 8 4...

Страница 38: ... 6 Hearth Combustible Material Exception NO VINYL ADHESIVE FLOORING Figure 8 7 Solid Fuel Floor Clearance SIDE VIEW MINIMUM 1 4 IN REQUIRED COMBUSTIBLE FLOOR UNDERNEATH APPLIANCE Appliance Size Depth X Width Y 25 in 16 in 25 3 4 in 30 in 16 in 30 3 4 in 35 in 16 in 35 3 4 in Vinyl Adhesive Flooring Minimums ...

Страница 39: ...s are spring loaded glass latches An example of the glass latch is shown in Figure 9 2 To release glass assembly use the supplied multi purpose tool to pull the two bottom spring loaded latches forward and allow them to retract away from the glass assembly Tilt the bottom of the glass assembly outward until the top latches disengage Replacing Fixed Glass Assembly Tilt the top of the glass assembly...

Страница 40: ...n place for shipping C Clean the Appliance Clean vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity D Accessories Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with...

Страница 41: ...actory may chip or crack if dropped or impacted KIT COMPONENTS Refractory shown in Figure 1 1 Left Refractory 1 Right Refractory 1 Back Refractory 1 Base Refractory Leave this manual with party responsible for use and operation Figure 2 Empty Firebox Figure 1 Refractory Kit Components INSTALLATION 1 Install base refractory See Figure 3 Figure 3 Base Refractory Installed Service Parts If replacemen...

Страница 42: ...5 Left Refractory Installed Figure 6 Left Refractory Handbend Tab Figure 7 Right Refractory Handbend Tab Figure 8 Refractory Kit Installed 3 Install left and right refractory bend down tabs to hold in place See Figures 5 6 7 2 Install back refractory See Figure 4 Be sure to hold back refractory in upright position until side panels get installed ...

Страница 43: ...e the remaining ember materials for use during appliance servicing The embers provided should be enough for 3 to 5 applications Figure 9 4 Placement of Embers F Ember Rocks Placement Ember rocks shipped in the appliance manual bag If desired ember rocks can be used to reduce the intensity of the accent lighting The heavier the ember rocks is applied the more the intensity of the accent lighting is...

Страница 44: ...y Rotate log so the burnout end touches pin A and bark end touches left refractory See Figure 4 CAUTION Risk of Cuts or Abrasions Wear protective gloves and safety glasses during installation Leave this manual with party responsible for use and operation MODEL EXCURSION I TRILLIANT25IN 1 1 A A B B 1 1 2 2 3 3 4 4 5 5 6 6 C C D D E E F F G G A A 7 7 EXCURSION I SRV LOGS LOG ID SRV PART MOLDED LOG 1...

Страница 45: ... Figure 7 Log 4 Installed 2 2 LOG 4 Place the left tip of Log 4 against pin B and lay flat on the burner Rotate the log forward until it contacts both pin C and pin E Log will contact all 3 pins See Figure 7 6 6 3 3 F F 4 4 4 4 C C B B E E 3 3 D D LOG 5 Notch on burnout end of Log 5 rests on grate tine bark end rests on notch of Log 1 Slide burnout end of log back until it touches Log 4 See Figure...

Страница 46: ... bar Ensure that the cutout section of the log is pushed up against the side of the pilot hood See Figures 14 15 and 16 CUTOUT CUTOUT A A B B Figure 11 Log Identification EXCURSION II TRILLIANT30IN 1 1 2 2 3 3 4 4 5 5 NOTICE To simplify the installation process use Figure 11 to positively identify each individual log before beginning installation 6 6 7 7 C C D D E E F F PILOT HOOD PILOT HOOD PILOT...

Страница 47: ... 2 Slide the burnout end of log back until it contacts the back refractory The back of right side of log will contact the right side refractory See Figure 18 Figure 20 Log 5 Installed 5 5 F F A A B B D D LOG 5 Notch on burnout end of Log 5 rests on grate tine bark end rests on notch of Log 1 Slide burnout end of log back until it touches Log 4 See Figue 20 1 1 Figure 16 Log 1 Installed Figure 17 L...

Страница 48: ... 23 Log 7 Installed 7 7 4 4 Figure 24 Complete Log Set LOG 6 Place the burnout tip of Log 6 against pin C and position between two rows of burner parts Place the bark end on the flat spot of Log 3 See Figure 21 C C LOG 7 Locate the notch on Log 7 See Figure 22 Place notch over grate tine and burnout end of log on notch of Log 4 See Figure 23 NOTCH NOTCH ...

Страница 49: ...III TRILLIANT35IN 1 1 2 2 3 3 4 4 5 5 NOTICE To simplify the installation process use Figure 25 to positively identify each individual log before beginning installation 6 6 7 7 C C D D F F G G PILOT HOOD PILOT HOOD 1 1 1 1 AIR SCOOP AIR SCOOP 8 8 E E PILOT HOOD PILOT HOOD 2 2 F F LOG 2 Place the bottom right end of log 2 against pin F and the left end of the log on the flat spot of log 1 Push the ...

Страница 50: ... FLAT SPOT FLAT SPOT Figure 33 Log 5 Installed Figure 34 Log 5 Installed Figure 35 Log 6 Installed 5 5 3 3 6 6 Figure 32 Log 4 Installed 4 4 5 5 3 3 LOG 4 Place the left tip of log 4 against pin A and lay flat on the burner Rotate the log forward until it contacts both pin C and pin E Log will contact all 3 pins See Figure 32 C C LOG 5 The tip of the burnout end of log 5 will contact pin G and the...

Страница 51: ...38 935F Figure 37 Log 8 Installed 4 4 Figure 36 Log 7 Installed 7 7 4 4 1 1 LOG 7 Locate the notch on log 7 Place notch over grate tine and burnout end of log in notch of log 4 See Figure 36 8 8 LOG 8 Notch on burnout end of log 8 rests on grate tine bark end rests on notch of log 1 See Figure 37 ...

Страница 52: ...fixed glass panel DO NOT operate the fireplace with the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to properly install one For more information refer to the instructions supplied with your decorative barrier front See Figure 9 5 for Reset Switch Detail The Reset Switch included with the surround needs to be wired to the appliance...

Страница 53: ...down the fireplace after 9 hours of continuous operation without receiving a command from the remote control If this occurs restart the appliance NOTICE Open windows for air circulation during fire place break in Some people may be sensitive to smoke and odors Smoke detectors may activate L Heat Management Heat Output Heat Output is managed through the RC400 remote con trol that comes standard wit...

Страница 54: ...xpands to 30 feet and 4 feet respectively Includes two liners termination cap and flashing Figure 10 1 Direct Vent Flex Liner Kits Figure 10 2 Direct Vent Flex Liner Accessory Kits Direct Vent Flex Liner Accessory Kits See Figure 10 2 LINK ZC ADPB Zero clearance chimney adapter DV 46DVA GK Adapter kit It is permissible to use DV 46DVA GK to connect colinear flex vent to SLP vent pipe to extend the...

Страница 55: ... or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions B Accessories Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Technologies approved optional acces sories with ...

Отзывы: