TRIM AND DOOR INSTALLATION
Installation of Noncombustible Trim Materials to the Front Face of the Fireplace
�����
�������������������
����
Noncombustible Facing
Material
Combustible Framing Members
Facing Material to Top of
Spacers
Figure 24
CAUTION:
Do not allow any trim materials to extend closer than 3/8 inch to the vertical edges of the
firebox opening if glass doors are to be installed.
Use Only Noncombustible Materials
Below Top of Spacers
Fireplace Face
Steel Lintel
(Optional)
CAUTION:
Do not cover or
restrict vent areas with any trim
materials.
WARNING:
The space between the face
of the fireplace and the noncombustible
facing material must be sealed. Failure to
properly seal this crack can cause a pos-
sible fire hazard and will void the MHSC
warranty.
12”
Max.
M1002
Mantel install
8/08
Figure 24A
Mantel Installation
Combustible Framing
Members to Top of Spacers
Combustible Mantel
Top Edge of Fireplace
18” Min. From Fireplace Opening to
Bottom of Combustible Mantel
(Manufacturuer Recommendation)
Top Edge of Fireplace
Opening
�����
��������������������
����
Figure 25
Combustible Surround Placement
Combustible Surround Materi-
als may be placed inside the
shaded areas. Combustibles
may not overlap edge of black
painted face more than 1/8”.
2
¹⁄₂
”
(Ref.)
Do Not Restrict
Side Air Inlets
Extend line from opposite rear
corner of firebox past inside open-
ing of the front face side panel.
Outline of
Fireplace
Firebrick
Glass Door Installation
This fireplace has been tested and listed for use with optional Model WSB48 glass doors.
For installation of the Model WSB48 glass doors, see the instructions provided with the doors.