background image

 

INSTALLER:  DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

10002823

9/00  Rev. 0

I

NSTALLATION

 I

NSTRUCTIONS

 & H

OMEOWNER

'

S

 M

ANUAL

DO NOT STORE 

OR USE GASOLINE OR OTHER 

FLAMMABLE VAPOURS AND/OR

 LIQUIDS IN THE VICINITY OF THIS OR 

ANY OTHER APPLIANCE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:

*  Do not try to light any appliance.

*  Do not touch any electric switch

*  Do not use any phone in your building. 

*  Immediately call your gas supplier  from 

  your neighbours phone. Follow the gas 

  suppliers instructions. 

*  If you cannot reach your gas supplier 

  call the re department

WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR 

EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be performed 

by a qualied installer, service agency or 

your gas supplier.

410 Admiral Blvd. Mississauga, Ontario, Canada.  L5T 2N6 

www.majesticproducts.com  /  www.vermontcastings.com

R

EAR

 V

ENTED

D

IRECT

 V

ENT

 

G

AS

 F

IREPLACE

DVR33

The Vermont Castings,

Majestic products company

Содержание DVR33

Страница 1: ...yourgas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED...

Страница 2: ...nstallation 6 Remote switch installation 7 EB 1 electrical box connection 7 Converting the appliance from LP to Natural Gas 8 General Venting Information Terminal Location 10 Venting Installation Inst...

Страница 3: ...eplace should not be used as a drying rack for clothing nor should Christmas stockings or decorations be hung on or around the replace 9 Under no circumstances should any solid fuels wood coal paper o...

Страница 4: ...L L M N O P Q Appliance Dimensions DVR33 A 838 mm 33 B 733 mm 28 7 8 C 416 mm 16 3 8 D 787 mm 31 E 560 mm 22 1 16 F 292 mm 11 1 2 G 375 mm 14 3 4 H 622 mm 24 1 2 I 127 mm 5 J 191 mm 7 1 2 K 216 mm 8...

Страница 5: ...ic purpose We recommend a non combustible hearth which projects out 12 305 mm or more from the front of the replace Cold climate Installation Recommendation When installing this unit against a non ins...

Страница 6: ...ce as well as the bottom Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection It is most convenient to bring the gas line in f...

Страница 7: ...the house electrical supply follow the steps below 1 Unscrew the retaining screw from the EB 1 base plate Fig 8 and remove the EB 1 assembly from the appliance 2 Remove the front cover of the EB 1 box...

Страница 8: ...ori ce supplied in the kit Re t the pilot hood assembly Do not over tighten the pilot hood The hood must return to its original alignment Take care not to damage the thermocouple thermopile or ignite...

Страница 9: ...10002823 0 DVR33 9 Vermont Castings Majestic Products Fig 10...

Страница 10: ...nlet to building or the combustion air inlet to any other replace 12 inches 305mm minimum K clearance to a mechanical air supply inlet 72 inches 1828mm minimum L clearance above paved side walk or a p...

Страница 11: ...combustible 2 50mm A Balcony with no side wall G Combustible Non Combustible 12 305mm G Balcony with perpendicular side wall H 24 610mm J 20 508mm H J B Recessed Location C Maximum depth of 48 1219mm...

Страница 12: ...vent section used in the system To join the twist lock pipes together simply align the beads of the male end with the grooves of the female end then while bringing the pipes together twist the pipe u...

Страница 13: ...all face plus 2 50 mm or the distance required if installing a second 90 elbow Fig 14 Step 4 Install the 4 100 mm vent to the appliance collar and secure with 3 sheetmetal screws Install the 7 175 mm...

Страница 14: ...em maintain its balance between the combustion air intake and the ue gas exhaust certain limita tions as to vent con gurations apply and must be strictly adhered to The Sidewall Vent Graph showing the...

Страница 15: ...gth in a system with a 7 5 vertical rise is 20 6 m and if a 90 elbow is required in the horizontal vent it must be reduced to 17 5 2 m In Fig 20 Dimension A plus B must not be greater than 17 5 2 m Th...

Страница 16: ...attach a 90 transition elbow Ensure that the inner and outer elbow ends are concentric before attaching the vertical lengths of venting Place the replace into position Fig 24 Measure the vertical heig...

Страница 17: ...ectly to the wall you may also use expanding plugs or an approved exterior construction adhesive You may also attach the termination with screws through the inner body into the 4 vent pipe however for...

Страница 18: ...imum of 8 2 4 m of vent pipe can be used between elbows Fig 30 A 7DVCS bracket must be used to support offsets This application will require that you rst determine the roof pitch and use the appropria...

Страница 19: ...into position and secure with screws or nails Fig 34 7 Install roof support Fig 32 and roof ashing making sure the upper ange of the ashing is under the shingles Fig 33 8 Install appropriate pipe sec...

Страница 20: ...Vertical Installation Offsets 7TDR45 for Rear Vent Application 90 transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustab...

Страница 21: ...r Vertical Installation Offsets 7DV45 for Rear Vert Application 90 transition elbow kit 7DVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7DVP610 6 to 10 adjustable...

Страница 22: ...htly dampened with lemon oil Do not use water or household cleaners on any brass components LOUVRE REMOVAL The top louvre panel is removed by lifting the panel vertically and pulling it away from the...

Страница 23: ...ace The left end of this log rest on the outer edge of the burner housing the inner top fork rest across the cutout in the left rear log A23 and the inner front fork rest on the front edge of the burn...

Страница 24: ...l gas go to the next step 7 Remove glass door before lighting pilot See Glass Frame Removal in manual 8 Visibly locate pilot by the main burner 9 Turn knob on gas control counter clockwise to PILOT ne...

Страница 25: ...10002823 0 DVR33 25 Vermont Castings Majestic Products TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE...

Страница 26: ...block not supplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wire across termin...

Страница 27: ...4b Pilot assembly PSE Prop 10001740 5 Pilot SIT top convertible 10002266 6 Pilot PSE with cable and electrode 10001824 Pilot ori ce SIT Nat 10002268 Pilot ori ce SIT Prop 10002269 Pilot ori ce PSE Na...

Страница 28: ...ssembly with bracket FK12 option ZA1110 20 Window frame assembly 10001803 21 Window glass with casket 10000961 Gasket window replacement kit 57317 22 Clamp window frame 54174 23 Window trim polished b...

Страница 29: ...2823 0 DVR33 29 Vermont Castings Majestic Products PARTS PICTORIAL L O H I PILOT ADJ P I L O T ON OFF 1a 1b 1c 1d 1e 2 3a b 4a b 5 6 7 8 9 10 10 11 12 13 14 15 16a b 17a b 18 19 20 21 22 23 24 25 26 2...

Страница 30: ...y fan system increases the ef ciency of the circu lation of the heating air The FK12 Fan Assembly is a xed speed fan system and does not allow for variable speed control It does not use the speed cont...

Страница 31: ...er housing 5 Loosely attach the top adjustable tabs to the studs located in the top of the rebox toward the front corners 6 Place the rear refractory panel in place Locate the lower edge of the panel...

Страница 32: ...play and a programmable 24 hour clock IMT Wall mounted thermostat control DECORATIVE FRAME TRIMS A selection of decorative frame trim kits is available for mounting around the outside of the appliance...

Отзывы: