Installation Instructions and 

Homeowner’s Manual

10007317  4/08   Rev.  13

Builder Rear Vent Direct Vent 

Models:  33LDVR, 36LDVR,
 

39LDVR, 43LDVR

DO NOT STORE OR USE 
GASOLINE OR OTHER 
FLAMMABLE VAPORS AND 
LIQUIDS IN THE VICINITY OF THIS 
OR ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

• 

Do not try to light any appliance. 

• 

Do not touch any electric switch; do 

not use any phone in your building. 

• 

Immediately call your gas supplier 

from your neighbor’s phone. Follow 

the gas suppliers instructions. 

• 

If you cannot reach your gas 

supplier call the fire department.

WARNING! 

IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING 
PROPERTY DAMAGE, PERSONAL 
INJURY OR LOSS OF LIFE.

PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

FOR YOUR SAFETY
Installation and service must be 
performed by a qualified installer, 
service agency or the gas supplier.

�������

����������

7317

LDVR COVER

1/05

���������

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Содержание 33LDVR

Страница 1: ...r from your neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier call the fire department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE INSTALLER CONSUMER SAFETY INFORMATION FOR YOUR SAFETY In...

Страница 2: ...ernate Switch Location 8 EB 1 Electrical Box 9 Electronic Gas Control Valve 9 General Venting Information General Venting 10 General Venting Information Termination Location 11 General Information Assembling Vent Pipes 12 How to Use the Vent Graph 13 Rear Wall Venting Applications Installation 13 Vertical Sidewall Applications Installation 15 Below Grade Installation 18 Vertical Through the Roof A...

Страница 3: ...ate ventilation and combustion air to operate properly 13 This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace 14 When the fireplace is not in use it is recommended that the gas valve be left in the OFF position 15 These units have been approved for bedroom use 33LDVR 36LDVR 39LDVR 43LDVR Certified To ANSI Z21 88 2005 CSA 2 33 2005 Vented Gas Fireplace ...

Страница 4: ... vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carb...

Страница 5: ... mm E 24 632 mm 24 610 mm 27 686 mm 31 788 mm F 11 292 mm 16 406 mm 16 406 mm 16 406 mm G 14 362 mm 18 476 mm 18 476 mm 18 476 mm H 19 501 mm 24 616 mm 24 616 mm 27 686 mm I 23 590 mm 27 705 mm 27 705 mm 30 775 mm J 4 121 mm 5 143 mm 5 143 mm 5 143 mm K 6 160 mm 8 203 mm 8 203 mm 8 203 mm L 8 225 mm 11 302 mm 11 302 mm 11 302 mm M 2 51 mm 2 51 mm 2 51 mm 2 51 mm N 3 86 mm 3 83 mm 3 83 mm 3 83 mm O...

Страница 6: ...hs refer to Figs 3a and 3b and the following Mantel Charts The fitting of a bay window trim kit does not effect the distances and reference points referred to in the diagram and chart Noncombustible mantels and legs may be installed at any height and width around the appliance When using paint or lacquer to finish the mantel such paint or lacquer must be heat resistant to prevent discoloration Clear...

Страница 7: ...l while flange B is for 5 8 drywall 3 Bend the desired flanges out 90 on both sides of the fireplace Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing Level the unit and secure it firmly in place FP1544 nail flange 1 05 Fig 4 Nailing flanges Flange Drywall Position Depth A 1 2 13 mm B 5 8 16 mm Flange Location for Desired Drywall Depth FP1539 A B Usin...

Страница 8: ...g 7 The gas control is equipped with a captured screw type pressure test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or flex connector use only approved fittings Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing See gas specification for pres sure details and ratings ...

Страница 9: ...y line to the brass screw polarized of the socket assembly 6 Connect the white wire of the power line to the chrome screw of the socket assembly 7 Connect the ground wire of the supply line to the green screw of the socket assembly 8 Refit the socket assembly back into the electrical box and replace the cover plate Secure the cable with the clamp on the outside of the EB 1 base plate and refit the E...

Страница 10: ...the front of the termination hood Do not locate termination hood where excessive snow or ice build up may occur Be sure to check vent termi nation area after snow falls and clear to prevent ac cidental blockage of venting system When using snow blowers make sure snow is not directed towards vent termination area Location of Vent Termination It is imperative the vent termination be located observ i...

Страница 11: ...let 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other appliances appliances 10 000 Btuh 3kW and 23cm for appliances 10 000 100 000 Btuh 30kW 36 91cm Btuh 3kW and 50 000 Btuh for appliances 100 000 Btuh 30kW 15kW 12 30cm for appliances 50 000 Btuh ...

Страница 12: ...High Temperature Sealant Hose Clamp FP1471 Fig 11 Apply high temperature sealant to 4 and 7 pipes Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors G Combustible 6 152 mm Noncombustible 2 51 mm F Combustible 6 152 mm Noncombustible 2 51 mm G Balcony with no side wall M Combustible Noncombustible 12 305 mm M Balcon...

Страница 13: ...ar wall is 20 508mm Fig 14 Only one 45 elbow is allowed in these installations Minimum clearances between vent pipe and com bustible materials are as follows Top 2 51 mm Sides 1 25 mm Bottom 1 25 mm Horizontal dimension from the outside face of the wall to the center of the fireplace vent flange Sidewall vent graph showing the relationship between vertical and horizontal dimensions for a Direct Vent...

Страница 14: ... 9 240mm 10 264mm Fireplace Hearth Framing Detail Opening for Noncombustible Wall 7 190mm VO584 100 Fig 15 Locate vent opening on wall ZCS101 Zero Clearance Sleeve 3 11 99 djt Max Length 12 305mm 8 Screws 2 8 Screws 2 Adjustable Zero Clearance Sleeve 8 Screws 2 Adjustable Zero Clearance Sleeve ZCS101 Fig 16 Adjustable zero clearance sleeve Firestop STEP 3 Measure from the fireplace collar or elbow ...

Страница 15: ...outcrop the vent pipe must flush up with the siding It is always best to locate the fireplace in such a way that minimizes the number of offsets and horizontal vent length The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace to the face of the outer wall Rear Wall Vent Installations Flex Vent Pipe Follow Steps 1 and 2 on Page 13 Step 3 Install the 4 102...

Страница 16: ... In Figure 23 Dimension A plus B must not be greater than 17 5 2 m The maximum number of 45 elbows permitted per side wall installation is two 2 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of the horizontal run MUST be reduced by V584 201 Horizontal Run 2 99 djt 10 ft 3048 mm 7 ft 6 in 2286 mm 7 ft 2134 mm CFM1...

Страница 17: ...required for combustible walls STEP 3 Attach the appropriate venting component s to the inner and outer flue collars of the fireplace using three 3 screws Fig 27 Follow with the installation of the inner and outer elbow Again secure joints with three 3 sheet metal screws CFM135 Zero Clearance Sleeve 2 26 01 sta Adjustable Zero Clear ance Sleeve Maximum Length 12 305mm 8 Screws 2 Adjust able Zero Cle...

Страница 18: ...ations When it is not possible to meet the required vent ter minal clearances of 12 305 mm above grade level a snorkel vent kit 7TDVSNORK is required It allows installation depth of down to 7 178 mm below grade level The 7 is measured from the center of the hori zontal vent pipe as it penetrates through the wall If venting system is installed below ground we recommend a window well with adequate a...

Страница 19: ...n approved for 1 Vertical installations up to 40 12 m in height Up to 10 3 m horizontal vent run can be installed within the vent system using a maximum of three 90 elbows Vertical Through the Roof Applications CFM148 Maximum 10 3 m Minimum 8 2 4 m Maximum 40 12 m Vertical Rise CFM148 Pipe Straps Every 3 914 mm Fig 33 Support straps for horizontal runs This Gas Fireplace has been approved for 1 Ve...

Страница 20: ...ovide a minimum of 1 inch clearance to the vent pipe i e the hole must be at least 9 x 9 240 x 240mm 5 Place fireplace into position 6 Place firestop s 7DVFS or Attic Insulation Shield 7DVAIS into position and secure Fig 35 7 Install roof support Fig 36 37 and roof flashing making sure upper flange is below the shingles Fig 36 8 Install appropriate pipe sections until the venting is above the flashing ...

Страница 21: ...t Up Installation 1 26 00 djt 40 12 m Storm Collar Roof Flash ing Vent Termination Roof 2 Min Roof Support Attic Insulation Shield Attic Insulation Joists Joists FP1022 Fig 37 Typical straight up installation Min 2 610 mm FP1185 Fig 38 Minimum termination to roof clearance ...

Страница 22: ...rmination Kit Starter Kit Model 7TDVSKV Vertical Venting for 7TDVSKV A order 1 12 to 6 12 roof pitch for 7TDVSKV B order 7 12 to 12 12 roof pitch for 7TDVSKV F order flat roof Starter Kit for Below Grade Installation Model 7TDVSKS Snorkel Kit Twist Lock Pipe Model 7FDVSKS Snorkel Kit Flex Vent Pipe Starter Pipe Model 7TDVP 20 8 24 Starter Pipe Bulk Model 7FDVP 30 8 30 Flex Pipe Bulk 45o Elbow 7TDV4...

Страница 23: ...e glass cleaner within the first few weeks of operation After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house The use of any non approved replacement glass will void all product warranties Care must be taken to avoid breakage of the glass Do not operate appliance with glass front removed cracked or br...

Страница 24: ...ront Center B161 B138 B138 Rear B158 BC14 BD15 Rear Left A41 Rear Right A42 Top Center A44 BD18 33LDVR 1 Place rear log left A41 on rear bracket ensure the notch on the left end locates against the bend up on the left side of rear bracket 2 Place rear log right A42 on rear bracket ensure the notch on the right end locates against the bend up on the right side of rear bracket and just rest the cut ...

Страница 25: ... rock material around the firebox base Rear B158 Front Left B160 Front Center B161 Front Right B159 LG481 Fig 42 Correct log placement for 36LDVR 39LDVR 1 Place rear log BC14 on rear bracket ensure log is centered and seated properly to the log support 2 Place front left log BC15 Use log s bottom hole to locate it onto the front support and just rest on top of the rear log 3 Place front right log B...

Страница 26: ...d the firebox base Rear BD15 Top Center BBD18 Front Right BD17 Front Left BD16 Lava Rock Front Center B138 Ember Material Lava Rock LG434 Fig 44 Correct log placement for 43LDVR Do not place any of the lava rock material on the burner housing assembly RN RP EN EP Models For units equipped with HI LO valves the flame adjustment is accomplished by rotating the HI LO adjustment knob located near the ce...

Страница 27: ...nt Gas Fireplace 10007317 Glowing Embers LG482 LG384 33LDV log flames 1 05 Glowing Embers LG384 Glowing Embers LG415 Glowing Embers LG435 Fig 48 Correct burner flame appearance for the LDVR fireplaces 33LDVR 36LDVR 39LDVR 43LDVR ...

Страница 28: ...ollow these instruc tions exactly B BEFORE LIGHTING smell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone To Turn Off Gas T...

Страница 29: ... to repair it call a qualified service technician Force or attempting repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water 5 Turn the remote switch if used OFF Turn the wireless remote if used...

Страница 30: ...d All Wiring Connections Replace Piezo Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs A Min Of 14mv Defective Valve Turn To Pilot Meter Should Read Greater Than 100mv If Not Replace Pilot Lights Main Burner Valve Is Turned On Wall Switch Is Not ...

Страница 31: ...e Continuously Monitored Heating Cycle Complete LED OFF NO YES NO NO YES Abnormal Operation 5 sec Inter Trial Delay LED Steady Flash Lockout Flame detected out of sequence Reset by interrupting ON OFF switch or power for 10 sec LED 5 Flashes Reverse power cord polarity LED 2 Flashes Reset by interrupting ON OFF switch for power for 10 sec Pilot Valve OFF Spark OFF Have three ignition trials been c...

Страница 32: ...ts are used Fig 50 Nova SIT820 Gas Valve D E F FC108 SIT regulator conversion 10 03 OF F P I L O T O FC107 SIT820 valve conversion 10 03 A B C OF F P I L O T O FC107 108 Natural Gas Log Locator Pin Propane Gas Log Locator Pin KT615 Fig 49 Move log locator pins to new locations on rear log sup port b Ensure the rubber gasket D is properly positioned and install the new HI LO pressure regulator to t...

Страница 33: ...them if necessary Check the manifold and supply pressures against the appli ance specifications Most of these components may require only an occasional checkup and cleaning and some may require adjustment If repair is necessary it should be performed by a qualified technician 1 Turn off pilot light at gas valve 2 Allow fireplace to cool if it has been operating 3 Remove window frame assembly Refer to...

Страница 34: ...without notice 33 36 39 43LDVR HI LO 22 21 19a b 18a b 41 17 30 33LDVR 1 1a 1b 1c 1d 1e 1f 1a 36LDVR 1 1g 1h 1i 2 3 6a b 8 7a b 9 11 12 13 14 15 16 20 23 24 25 26 29 31 32 33 34 35 37 39 7317 LDVR parts 1 05 40 1 39LDVR 1a 1b 1c 1d 43LDVR 1b 1c 1a 1d 1g 42 43 33LDVR units GFRN2I0 GFRL2I0 GFRE2I0 36LDVR units GFRN2J1 GFRL2J1 GFRE2J1 39LDVR units GFRN2K0 GFRE2K0 43LDVR units GFRN2N0 GFRE2N0 ...

Страница 35: ...ilot Hood 10002385 10002385 10002385 10002385 10 Manifold Tubing w Fittings 57318 57318 57318 57318 11 Thermocouple RN RP 53373 53373 53373 53373 12 Thermopile RN RP 51827 51827 51827 51827 13 Electrode Ignitor w Cable RN RP 10001297 10001297 10001297 10001297 14 Electrode Ignitor EN EP 52465 52465 52465 52465 15 Cable Ignitor EN EP 10000696 10000696 10000696 10000696 16 Sensing Electrode EN EP 57...

Страница 36: ... Control from Synetek EN 10007939 10007939 10007939 10007939 40 Wire Harness EN Synetek low voltage 10008139 10008139 10008139 10008139 41 Wire Harness EN Synetek high voltage 10008140 10008140 10008140 10008140 42 Clevis Pin 10008615 10008615 10008615 10008615 43 Clip Pin Hitch 10008616 10008616 10008616 10008616 Fuel Conversion Kits Conversion Kit NG to LP 33LDVR Kit 10008233 36LDVR Kit 10008235...

Страница 37: ...onveniently located wall socket Method B Using EB 1 Receptacle Box The EB 1 receptacle box Pt ZA1200 may be hard wired into the house supply The fan lead is then plugged into the EB 1 box For instruction on wiring the EB 1 receptacle box see the earlier chapter in the Installation section of this manual FK12 This auxiliary fan system increases the efficiency of the circulation of the heating air Th...

Страница 38: ...wiring Take care when handling the refractory panels as they are fragile until held in place and supported Installation Refer to Figures 54 55 1 Remove the front window frame assembly 2 Remove the logs 3 Place the rear refractory panel in place Locate the lower edge of the panel in the ledge formed by the top of the rear log support bracket 4 Slide the side refractory panels into place to hold the...

Страница 39: ... 33LDVR 33DVMTKB Black Adjustable Medium Trim Kit Appliance Model Trim Kit 36LDVR ADVMTKP Polished Brass 36LDVR ADVMTKS Pewter 36LDVR ADVMTKB Black 39LDVR ADVMTKP Polished Brass 39LDVR ADVMTKS Pewter 39LDVR ADVMTKB Black Screen Door Kit Appliance Model Kit Model 33LDVR 33DVSDKS Pewter 36LDVR 36DVSDKS Pewter 33LDVR 33DVSDKB Black 36LDVR 36DVSDKB Black 39LDVR 39DVSDKB Black 36LDVR 36DVSDKR Rustic Br...

Страница 40: ...40 LDVR Series Direct Vent Gas Fireplace 10007317 ...

Страница 41: ...41 LDVR Series Direct Vent Gas Fireplace 10007317 ...

Страница 42: ...42 LDVR Series Direct Vent Gas Fireplace 10007317 ...

Страница 43: ...er must pay for any Authorized Dealer in home travel fees or service charges for in home repair work It is the dealers option whether the repair work will be done in the customer s home or in the dealer s shop Ifuponinspection thedamageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisi...

Страница 44: ...82 83 59 36LDVRRN 57 5 81 82 58 36LDVRRP 57 5 82 83 58 36LDVREN 63 6 81 82 58 36LDVREP 63 6 82 83 58 39LDVRRN 50 2 76 79 63 39LDVRRP 50 2 79 80 63 39LDVREN 54 2 78 79 63 39LDVREP 54 2 79 80 63 43LDVRRN 54 3 77 78 63 43LDVRRP 54 3 78 79 63 43LDVREN 58 3 77 78 63 43LDVREP 58 3 78 79 63 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...

Отзывы: