MISCOM7028GX/MISCOM8028GX Series Industrial Ethernet Switch
- 10 -
Power
Voltage Range
Operating
Temperature
Storage
Temperature
Humidity
AD220
85~264VAC/
110~370VDC
-40
℃
~
+70
℃
-40
℃
~
+85
℃
5
~
95%
Attention
:
2.7. Ground
The panel of the MISCOM7028GX/MISCOM8028GX Series Switches has
a grounding screw. Press one end of the grounding wire to the cold-pressing
terminal and fix it to the grounding hole of the housing with the grounding screw.
Connect the other end of the grounding wire to the ground reliably. The
grounding wire cross section is not less than 2.5
㎜
².
Important notes:
Power on operation: Connect the power supply cable with terminal
blocks of the equipment according to above diagram definition, then power
on.
Power off operation: Plug out the socket first, then take down the
power cable.
Please follow the above operation order.
The supported power specifications of the device is 220VAC/DC.
Please confirm whether the power supply is compliance with the requested
power specification printed on the label of the device before powering on,
so as not to damage the device.