MIEN6208 Series Management Industrial Ethernet Switch
- 11 -
When use fiber cable port, remove SC/FC/ST port cover; When it finish
work, please put the plastic cover to protect the fiber optic head, keep clean.
Check the fiber optic cable head whether it clean or not. If it not clean,
will effect port and communication quality.
One fiber optic head connect with Ethernet switch optic port, the other
fiber head connect with another equipment fiber optic interface equipment.
After connection, please check switch the front interface’s LNK/ACT LED
lights. If lights on, connection is available.
Attention:
This switch uses a laser to transmit signals over fiber optic cables. The
laser meets the requirements of Class 1 laser products, and normal
operation is harmless to the eyes. However, when powering up the unit, do
not look directly at the optical transmission port and the fiber optic terminator
end face.
The steps to connect the pluggable fiber optic module are as follows ,
please use following steps:
- When use fiber cable port, remove SC/FC/ST port cover; When it finish
work, please put the plastic cover to protect the fiber optic head, keep clean.
- Check the fiber optic cable head whether it clean or not. If it not clean,
will effect port and communication quality.
- One fiber optic head connect with Ethernet switch optic port, the other
fiber head connect with another equipment fiber optic interface equipment.
- After connection, please check switch the front interface’s LNK/ACT LED
lights. If lights on, connection is available.
3.3. Testing guide
3.3.1. Self-examination
When connection equipment, the front panel power supply indicator light
will blinking once, it means working well. After a while Power supply indicator
light is on. Run indicator light (system status LED) will blink interval 1s.
3.3.2. Copper port testing
As below picture. Powering on the switch, connect any two copper ports to
the network ports of the two test computers through the direct connection
network cable, and send ping commands to each other. Both parties can
correctly ping each other without losing packets. At the same time, the yellow
light on the corresponding port should be always on (the computer network
card works in the 100M state) or often off (the computer network card works in
the 10M state), and the green light on the corresponding port should flash. The
hardware of the two electrical ports tested is working properly. The following