MIEN6208 Series Management Industrial Ethernet Switch
- 10 -
Checking DIN-Rail is fixed firm, DIN-rail is installed on other equipment,
whether there is enough space .
Checking DIN-Rail whether suitable for power input.
Please selected the correct position. As below behind picture shows:
Insert DIN-Rail into DIN-Rail slot and as schematics 2-1 shows turning
equipment.
As below shows, insert DIN-rail into DIN-Rail slot and confirm the
MIEN6208 reliable equipment installed on the DIN-rail.
3.2.2. Cable connection
After installation, could prepare for cable connection as below:
Working interface connection
This Ethernet switch supplied terminal device interface is
10Base-T/100Base-TX RJ45 port, use the direct cable connect with terminal
equipment, use cross wire connect with network equipment
CONSOLE connection
This products CONSOLE port could connect with serial interface which
control PC.
Power connection
When all cable connect well, could connect with Ethernet switch’ standard
power.
3.2.3. Fiber connection
This series Ethernet switch provide 0/2/4 100Base-FX single mode or
multi-mode fiber optic ports. The interface type can be selected according to
requirements of SC / ST / FC.
Attention
:
This switch uses lasers to transmit signals over fiber cable. Laser Class 1
laser/LED products can cause serious damage on the eyes harmless. When
the equipment is power on, please do not stare directly into the laser beam.
Connection fiber cable ,please use following steps: