MIEN2016/2018/2024/2026 Rack Mount Industrial Ethernet Switch

- 9 -

Before laying the cable, check whether the cable is damaged, whether

there are factory records and quality assurance certificates that prove its
quality

The specifications, quantity, routing direction, and location of the cables

to be laid should meet the design requirements of the construction drawing,
and the wiring length of each cable should be determined according to the
actual location

User cables and power cords are laid separately

There must be no broken wires or joints in the middle of the laid cables

The cables should be laid out neatly in the aisle, and the bends should

be even, smooth and straight

The cable should be straight in the channel, and should not go out of the

channel and block other cable entry and exit holes. The cable should be tied
and fixed at the location of the cable exit from the channel or the cable bend.

When the cables, power cords, and ground wires are laid in the same

slot, the cables, power cords and ground wires cannot be overlapped or mixed.
When the cable is too long, the cable must be neatly placed in the middle of the
cable rack, and cannot be pressed on other cables

When laying pigtails, prevent the optical cable from knotting and

minimize the turning points, and the turning radius should not be too small. The
lashing should be moderately tight and not too tight. When laying on the cable
rack, it should be placed separately from other cables

Both ends of the cable should have corresponding marks, and the

content of the marks is concise and easy to maintain

Note:

When laying pigtails, prevent the optical cable from kinking and

minimize the turning point, and the turning radius should not be too small. If
the turning radius is too small, it will cause serious loss of the link optical
signal. Affect the quality of communication.

2.3. Simple test

2.3.1. System self-check

All the service port indicators on the front panel will flash once when the

device is powered on, indicating that the port is working normally. After that, the
corresponding Power will always be on, and the Run light (system running
status indicator) will flash at intervals of 1s.

Содержание MIEN2016

Страница 1: ...MIEN2016 2018 2024 2026 Rack Mount Industrial Ethernet Switch User Manual Edition V2 0 Wuhan Maiwe Communication Co Ltd ...

Страница 2: ...his manual does not represent for corresponding authorization on these information Our company attempts to ensure the accuracy and applicability for the information provided in this manual however our company does not assume any responsibility for the use of these information and does not assume any joint responsibility for the use of these information There may be a few technical or typographical...

Страница 3: ...ected with each other frequently inspection is needed Please keep the fiber socket and plug clean Do not look directly at the fiber section when the equipment is working Please keep the equipment clean and wipe it with a soft cotton cloth if necessary Please do not repair the equipment by yourself unless there is clear instructions in the manual Under the following circumstances please cut off pow...

Страница 4: ... Description 3 2 1 Hardware structure 3 2 1 1 System structure 3 2 1 2 Whole machine structure 3 2 2 Hardware installation 5 2 2 1 Installation requirements 5 2 2 2 Host installation 6 2 2 3 Cable connection 7 2 2 4 Fiber optic connection 8 2 2 5 Laying cables 8 2 3 Simple test 9 2 3 1 System self check 9 2 3 2 Copper port test 10 2 3 3 Fiber port test 10 3 Maintenance and Service 12 3 1 INTERNET ...

Страница 5: ...he switch uses rack installation This series of industrial Ethernet switches has a total of 26 100M ports at most and its switching bandwidth is 8 8G They all support 8K entries in the MAC address table 1 2 Characteristic 1 2 1 Industrial network performance Broadcast storm suppression Optional 100Base FX with different transmission distances and different types of optical fiber interfaces Store a...

Страница 6: ...nt network information exchange capabilities Technical index IEEE standard 802 3 802 3u 802 3x Exchange method store and forward Exchange bandwidth 8 8G Flow control full duplex flow control half duplex back pressure control MAC address 8K Transmission distance twisted pair cable 100m fiber 100Mbps maximum 20 40 60 80km Broadcast storm real time broadcast storm suppression EMC standard EN61000 4 2...

Страница 7: ...per ports and serial ports have EMC protection 2 1 2 Whole machine structure The chassis is a 19 inch 1U rack structure as shown in Figure 2 1 the whole machine adopts a six sided fully enclosed structure Abandon the traditional flow fan heat dissipation form reduce the power consumption of the whole machine but also improve the stability of the system The dimensions are 482 6 44 210mm Figure 2 1 ...

Страница 8: ...ST or FC Optical fiber interfaces need to be used in pairs TX and RX are a pair TX port is the optical transmitting end connected to the optical receiving end RX of the optical interface of another remote switch RX port is the optical receiving end connected to the same optical interface of the same remote switch The optical transmitter TX The 100M fiber interfaces mainly include SC ST FC As shown...

Страница 9: ... 4 Schematic diagram of power input terminal The power requirements of this series of switches are shown in Table 2 2 Table 2 2 Switch power requirements Voltage voltage range Operating temperature Storage temperature Humidity 220VAC DC 85 265 VAC 47 63Hz or 110 370 VDC 40 C 85 C 40 C 85 C 5 95 2 2 Hardware installation 2 2 1 Installation requirements The industrial Ethernet switch is a single str...

Страница 10: ...aximum current allowed by lines of different widths If the current exceeds the maximum rated current the wire will overheat and cause serious damage to the equipment At the same time you must also pay attention to the following Separate the paths of power lines and equipment lines If the two paths must cross make sure that these lines are perpendicular at the intersection It is not allowed to lay ...

Страница 11: ... situation of the rack should be checked before installation It mainly includes the following two contents Is there enough space for installing this product Is there a power supply suitable for the work of this product When installing first determine the installation position of the product align the mounting holes of the switch with the holes on the rack and fix it with 4 screws The recommended s...

Страница 12: ... a transmission distance greater than 60km do not use short optical fibers below 20km to connect so as not to cause the optical saturation and overpower at the receiving end of the module to burn The steps to connect the pluggable fiber optic module are as follows Remove and keep the rubber sleeve of the LC SC or FC port When not in use put on a rubber sleeve to protect the fiber terminator Check ...

Страница 13: ...the cables power cords and ground wires cannot be overlapped or mixed When the cable is too long the cable must be neatly placed in the middle of the cable rack and cannot be pressed on other cables When laying pigtails prevent the optical cable from knotting and minimize the turning points and the turning radius should not be too small The lashing should be moderately tight and not too tight When...

Страница 14: ... the test computer through a direct connected network cable and PING commands are sent to each other and both parties can correctly PING to each other without packet loss At the same time the LINK ACT light corresponding to the optical port should be on It means that the hardware of the two fiber ports under test is working normally and the other optical ports are tested in the same way Figure 2 8...

Страница 15: ...r of bytes to send data packets t refers to continuously sending data run ping 192 168 0 10 l 1000 t in test computer 2 in the same way If test computer 1 returns Reply from 192 168 0 11 bytes 1000 time 10ms TTL 128 test computer 2 returns Reply from 192 168 0 10 bytes 1000 time 10ms TTL 128 use CTL after running for more than 10 minutes The C command statistics packet loss rate is 0 indicating th...

Страница 16: ...ement 3 1 INTERNET service Through the technical support section of Maiwe website you can get more useful information and usage skills 3 2 Technical support telephone service Users who use the products of Wuhan Maiwe Communication Co Ltd can call the technical support office of Maiwe Maiwe has professional technical engineers to answer your questions and help you in the first time to solve the pro...

Страница 17: ...4 2026 Rack Mount Industrial Ethernet Switch 13 Our company has the right to change the product model without notifying the user For the latest information please consult our company s market or technical support staff ...

Страница 18: ... MAIWE COMMUNICATION CO LTD Add Building 2 Area E Phase ii Optical valley core center No 52 Liufang road East Lake Hi tech Development Zone Wuhan China Phone 027 87170215 16 Fax 86 027 87170217 www maiwe com ...

Отзывы: