Installation Preparations
MyPower S6600 Series Routing Switch Installation Manual
40
copyright
©
2015 Maipu All rights reserved.
4.3.9
4.3.9
4.3.9
4.3.9
View
View
View
View Swappable
Swappable
Swappable
Swappable Optical
Optical
Optical
Optical Module
Module
Module
Module Information
Information
Information
Information
You can use the
show
show
show
show optical
optical
optical
optical all
all
all
all
command to view the work parameters of all
optical modules used on S6600 series routing switch.
switch#show optical all
Name
VendorName
LaserWaveLen(nm) Temperature(C)
Voltage(V)
TxPower(dBm) RxPower(dBm)
---------------------------------------------------------------------------------------------------------------------------
te1/0
Eoptolink
850
50.355469
3.248500
-1.880231
-2.297373
te1/1
TRIXON INC.
850
54.609375
3.289300
-2.032869
-6.575773
te1/4
TRIXON INC.
850
56.531250
3.286900
-2.290744
-1.822364
te2/0
TRIXON INC.
850
56.730469
3.289300
-2.407100
-1.335354
te2/1
Eoptolink
850
51.058594
3.252600
-2.491061
-2.288537
te2/6
Eoptolink
850
49.363281
3.282100
-2.601904
-0.930727
te2/7
TRIXON INC.
850
55.523438
3.289300
-2.254830
-1.864857
T
T
T
T
A B L E
A B L E
A B L E
A B L E
4
4
4
4
1 0
1 0
1 0
1 0 T
T
T
T
H E
H E
H E
H E D E S C R I P T I O N
D E S C R I P T I O N
D E S C R I P T I O N
D E S C R I P T I O N O F
O F
O F
O F T H E
T H E
T H E
T H E K E Y
K E Y
K E Y
K E Y F I E L D S
F I E L D S
F I E L D S
F I E L D S D I S P L A Y E D
D I S P L A Y E D
D I S P L A Y E D
D I S P L A Y E D V I A
V I A
V I A
V I A S H O W
S H O W
S H O W
S H O W O P T I C A L
O P T I C A L
O P T I C A L
O P T I C A L A L L
A L L
A L L
A L L
Field
Field
Field
Field
Description
Description
Description
Description
Name
The name of the port where the optical
module is located, such as te1/0
Vendor Name
The manufacturer
name
of
the
optical
module, such as Eoptolink
LaserWaveLen(nm)
The center wavelength of the optical module
laser, such as 850
Temperature(C)
The temperature of the optical module (only
for the optical module supporting the DDMI
function), such as 50.355469
℃
Voltage(V)
The work voltage of the optical module (only
for the optical module supporting the DDMI
function), such as 3.248500V
TxPower(dBm)
The sending power of the optical module
(only for the optical module supporting the
DDMI function), such as -1.880231dBm
RxPower(dBm)
The receiving power of the optical module
(only for the optical module supporting the
DDMI function), such as -2.297373dBm
Besides, you can use the following commands to view the details of the inserted