S12800 Routing Switch Installa
tion Manual V1.0
Maipu Confidential & Proprietary Information
Page 66
4.3.8 View LPU Card Status Information
You can use the show system lpu <slot number> command to view the information of the
LPU card on S12800, including card online information, card name, card status information,
the hardware and software version information of the card, the card storage space status
information, and so on. For example:
switch#show system lpu 4
System Card Information(Lpu 4 - ONLINE)
----------------------------------------------------------------
Type: SM128-16QXGE-DA(V1)[0x85862003]
Status: Start Ok
Last-Alarm: Normal
Card-Port-Num: 16
Card-SubSlot-Num: 0
Power-INTF-Status: Normal
Power-Card-Status: On
Serial No.:
Card-Name: SM128-16QXGE-DA(V1)
Description:
Power-RT-Infomation:
Voltage-In: 3.28 V
Hardware-Information:
PCB-Version: 002
CPLD-Version: 103
Software-Information:
Monitor-Version: 1.20
IOS-Version: 8.1.0(1)
Temperature-Information:
Temperature-State:
Temperature = 65°C
Last-Alarm = Normal.
CPU-On-Card-Information: < 1 CPUs>
CPU-Idx: 00
Status: Normal
Core-Num: 0001
Core-State:
Core-Idx-00
Core-Status: 0000
Core-Utilization: 0%
Temperature:
Temperature-State:
Temperature = 42°C
Last-Alarm = Normal.
MEM-On-Card-Information: <1 MEMs>
MEM-Idx: 00
MEM-State:
BytesFree = 1758468664 bytes
BytesAlloc = 377271848 bytes
BlocksFree =
24 blocks
BlocksAlloc =
23145 blocks
MaxBlockSizeFree = 532676608 bytes
SizeTotal = 2135740512 bytes
CMM-Information:
Hardware-Type: 0000
Software-Version: 1.0.23
----------------------------------------------------------------
STATISTICS:
1 IN, 0 OUT, 1 IERR, 0 OERR
Table 4-7 Key field description of the information displayed via show system lpu <slot
number>
Field
Description