S12800 Routing Switch Installa
tion Manual V1.0
Maipu Confidential & Proprietary Information
Page 109
Name
Indicator Color
Status description
Off: The CMM serial port has no data sending and
receiving
SFU
Red and green
Green/on: All online SFU cards are loaded completely
and the SFU cards can work normally
Red/on: The SFU cards are all not online, or at least
one SFU card is not in the normal working state.
Note: As long as one SFU card is not in start ok state,
turn on the red no matter in loading, un-installing,
loaded, or loaded.
LPU
Red and green
Green/on: All online LPU cards are loaded completely
and the LPU cards can work normally
Red/on: The LPU cards are all not online, or at least
one LPU card is not in the normal working state.
Note: As long as one LPU card is not in start ok state,
turn on the red no matter in loading, un-installing,
loaded, or loaded.
MPU
Red and green
Green/on: The master MPU card is loaded completely
and works normally
Red/on: The master MPU works abnormally
FAN
Red and green
Green/on: All fan modules of the device are in place
and work normally
Red/on: One or more fan modules work abnormally;
one or more fan modules are not in place.
PWR
Red and green
Green/on: The device has at least one power module in
place and the in-place power works normally.
Red/on: The in-place power module of the device has
alarm.
Power button light
green
green/on: The device is powered on.
green/slow-flashing 0.2Hz: The device is in the standby
state.
A.6
Power Module Specification
S12800 route switch supports the AC power supply mode.
The power module has the following specification:
Specification
Overview