112
2
Heating Circuit
Heating Circuit
encloses all for heating relevant parameters and settings. It can occur up to 6 menu items
Heating Circuit.
Heating Circuit
is in the Main menu
Heating circuits settings has following menu
items:
• Mode
• Room Temp Heating
• Room Temp Set back
• Time Allocation
• Values
• Time 1
• Time 2
• Party
• Vacation
• Heatingcurve
Off
Only the frost protection function is active.
Auto
The Furnace starts in the heating times according to the Set
room temperature.
Heating
The Furnace heats constantly according to the Set room
temperature.
Set back
The Furnace heats constantly according to the Set back room
temperature.
The operating mode of the heating circuits can only be changed if the plant
operating mode is set to AUTO.
The adjusted heating limits and maximum flow temperatures are used in all
operating modes.
Choose your room temperature (Temperature within the heating times).
Choose Room Temp Set back (= Minimum temperature beyond the heating
times).