background image

25

6 720 607 160

18. Short Parts List

Item

Baxi Potterton 

Number

Spark Electrode

5111115

Sensing Electrode

5111116

Flow Sensor

5111117

Control Unit

5111118

Fuse T 1.25A

5111119

Fuse 2A

5111120

Pressure Switch

5111121

Fan 5111122

Gas Valve

5111123

Содержание MULTIPOINT FF

Страница 1: ...MULTIPOINT FF Room Sealed Fan Assisted Water Heater 6 720 607 160 04 02 JS Please leave these instructions with the user User Operating Installation and Servicing Instructions...

Страница 2: ...mponent or part which becomes defective during the guarantee period as a result of faulty workmanship or materials whilst in normal use will be repaired or replaced free of charge This appliance confo...

Страница 3: ...6 Installation Regulations 8 7 Siting the Appliance 9 8 Siting the Flue Terminal 10 9 Air supply 11 10 Gas supply 11 11 Electrical 13 12 Installation 13 13 Commissioning 18 14 Performance optimization...

Страница 4: ...art the appliance consult your installer 1 Turn the main switch to position 0 Off The hot water temperature is set by the control position Turn the control clockwise to increase the temperature and an...

Страница 5: ...utton 17 Safety solenoid EV1 25 Water filter 28 Hot water pipe 29 Cold water pipe 35 Gas inlet pipe 42 Gas filter 49 Injector 50 Burner 55 Heat exchanger 92 Gas valve 117 Ignition electrode 118 Sensin...

Страница 6: ...ric Vertical Flue Kit Sales Code 238015 Flat roof flashing kit Sales Code 31 19040 Pitched roof flashing kit Sales Code 31 19041 Wall liner internal flue fixing kit Sales Code 238012 Terminal guard Sa...

Страница 7: ...7 6 720 607 160 4 Dimensions and Fixings Fig 5...

Страница 8: ...son and be in accordance with the relevant requirements of the current Gas Safety Installation and Use Regulations the building regulations Scotland Consolidation the local building regulations the cu...

Страница 9: ...clearances must be available for installation and for servicing 7 7 The minimum clearances required for Operation are 7 8 The appliance can be installed in a cupboard used for airing clothes provided...

Страница 10: ...y plume when the appliance is operated Siting where this could cause a nuisance should be avoided 8 7 Take care to ensure that combustion products do not enter ventilated roof voids Fig 7 Siting of th...

Страница 11: ...nces required for operation will normally be adequate 9 4 Refer to BS 6798 and BS5440 2 for additional information 10 Gas Supply 10 1 The gas installation should be in accordance with BS 6891 10 2 The...

Страница 12: ...12 6 720 607 160 Fig 8 5 Temperature sensor 6 Water flow sensor 7 Fuse1 25A 8 Fuse 2A 92 Gas valve 117 Ignition electrode 118 Sensing electrode 119 Temperature limit stat 226 Fan 228 Pressure switch...

Страница 13: ...wall through the hole located in the valve mounting bracket To increase access to this area of the appliance the control box may be temporarily re positioned depress the two curved finger tab latches...

Страница 14: ...rtical Up to 4 0 m Max 58 Up to 3 5 m 58 3 5 m 4 0 m Max 68 Up to 2 5 m 58 2 5 m 4 0 m Max 68 Vertical configuration Direct vertical rise from the appliance Vertical Adapter 1 x 90 degree bend Configu...

Страница 15: ...ood the opening around the flue 12 3 2Extended Horizontal Flue Installation The flue may be extended to the maximum configuration lengths shown in Table 11 with the application of 1m extension kits 45...

Страница 16: ...Z Take the assembly apart and shorten the inner and outer tubes by dimension Z Remove any burrs Fit the Appliance Adaptor to the top of the appliance using 3 screws provided Slide the Flue Tube Assem...

Страница 17: ...Outer Extension Tube s and Appliance Adaptor Secure using the screws provided Fully tighten the fixing bracket s on the extension s and the terminal clamp bracket in the roof Make good around the Fla...

Страница 18: ...o confirm the burner pressure stated in table 1 loosen screw pos 1 and connect a pressure gauge to the pressure test point Replace the control box and outer case turn on the gas isolation valve With t...

Страница 19: ...place the rotary temperature control knob at position 45 14 3 Press and hold the burner indicator button Fig 3 key13 and set the main switch to position I on The green burner indicator button blinks T...

Страница 20: ...and retain the fibre washer Lift and rotate the front edge of the burner backward through 180 degrees With the burner oriented horizontally and upside down withdraw forward beneath the combustion cha...

Страница 21: ...Replace the transparent plastic cover on the gas valve and confirm the adjustments for maximum and minimum by repositioning the rotary temperature control knob at position 60 and position 55 and obser...

Страница 22: ...nce from the incoming cold water supply open a hot tap and drain down the appliance via the fitted drain cock Undo the two retaining screws from the heat exhanger bracket Disconnect the heat exchanger...

Страница 23: ...panel of the control unit and remove Replace appropriate fuse as per Fig 8 key 7 or 8 16 8 Fan Remove all wiring connections from the fan Remove the pressure sensing tubes from the fan noting their po...

Страница 24: ...24 6 720 607 160 17 Fault Finding Note Installation maintenance and repairs must be carried out only by a competent person...

Страница 25: ...rt Parts List Item Baxi Potterton Number Spark Electrode 5111115 Sensing Electrode 5111116 Flow Sensor 5111117 Control Unit 5111118 Fuse T 1 25A 5111119 Fuse 2A 5111120 Pressure Switch 5111121 Fan 511...

Страница 26: ...26 6 720 607 160 19 Notes...

Страница 27: ...27 6 720 607 160...

Страница 28: ...049 SERVICE GB 08706 096 096 LITERATURE REQUEST GB 08706 060 623 TECHNICAL IE 1850 560 570 Baxi Potterton A Trading Division of Baxi Heating U K Ltd Brownedge Road Bamber Bridge Preston Lancashire PR...

Отзывы: