The following settings should only be configured by a qualified technician.
The parameters listed below can be set during installation of afterwards, accessing the settings menu as
follows:
•
Machine in standby with door open.
•
Press buttons 2 and 3 together (cycle selection and
START
) for 5 seconds and enter the key
CH 12
(buttons 2 and 3 to change the parameter, 1 to confirm).
•
Then press button 1 (
ON/OFF
) repeatedly to scroll through the following headings, enabling and/or
changing them using buttons 2 and 3 (the modified parameter is memorised without being
confirmed). The list of parameters may vary according to the type of dishwasher.
Language
Language selection
Boiler
Temperature
Boiler temperature settings for programmes. In the versions with
atmospheric boiler (rinse pump) there are different settings for each
programme (b1 – b2 – b3)
Tank
Temperature
Tub temperature regulation for programmes. Rinse pump versions have
different settings for each programme (t1 – t2 – t3)
Thermo - Stop
Enabling the Thermostop function, which guarantees the correct
rinse temperature.
Energy
Saving
Enabling the Energy Saving function, which guarantees
energy savings when the dishwasher is on but not in use.
Detergent
Pump
Manual operation of detergent doser
Rinse Aid
Pump
Manual operation of rinse aid doser
Manual
Rinse
Manual operation of the rinse pump
Dosage
Detergent
Detergent dosing time
Dosage
Rinse Aid
Rinse aid dosing time
Water
Hardness
Setting the supply water hardness (dishwashers with water softener): enter
the values given in the table below
Set Number
Service Cycles
Setting and enabling the cycle counter to enable the servicing warning
Autostart
Autoenabling
Automatic enabling of automatic starting
Cycle Counter
Cycle counter
Once all necessary parameters have been set, to exit and memorise any changes simply press and
hold button 1 for a few seconds until the on-line dashes appear.