UK│ LED displays
20
LED displays on the ZEG2 EC-FB
Status
LEDs: Status displays
Unit in operation:
Normal ope-
ration without
taking the
humidity sensor
into account
●
Timer on for
15 mins
●
Timer on for
30 mins
● ●
Timer on for
60 mins
● ● ●
Fault in the
wireless
connection
x x x
Unit fault
x x
Registration
mode activated
x ● x
Registration
confirmation
● ● ● ● ● ● ● ● ● ●
Battery low
o
RESET remote
control
o o
● = green / x = red / o = orange
Error codes
Fault rectification only by trained specialist
Chapter 14.
Red LED
Meaning
Flashes 1x
Motor doesn’t start up.
Check whether the mains fuse
is switched on and the mains
plug is plugged in. If the thermal
overload protection has triggered:
Wait until motor and tempera-
ture limiter have cooled.
Cool-down time can be up to
15 minutes. Only switch the
unit on again after this time.
Flashes 2x
Humidity sensor is not sending
any data.
Flashes 3x
Error in the wireless
connection.
1. Scope of delivery
ZEG2 EC:
Central ventilation unit with
integrated humidity sensor and connecting
cable with mains plug (1.2 metres, fully
wired), mounting material (4 screws and
4 fixing dowels). These mounting and
operating instructions.
ZEG2 EC-FB:
Wireless remote control with
wall-mounting frame, 3 V battery (CR 2032),
mounting material (2 screws and 2 fixing
dowels).
When unpacking the unit, check to
make sure that the delivery is
complete. Please contact the dealer
if any accessories are missing or if
there has been any damage in
transit.
2. General notes
Read these instructions carefully
before operation or installation and
follow the information they contain.
Keep the instructions safe for use
later on.
2.1 Specialist installer qualification
The ventilation unit may only be installed and
commissioned by a trained specialist, in
accordance with these instructions.
You are considered a ventilation specialist if
your specialist training and experience in
ventilation technology enables you to
correctly and safely undertake installation in
accordance with planning documentation and
these instructions. In addition, you must be
able to recognise, assess and avoid risks due
to incorrect installation.
Only a trained electrician is permitted to work
on the electrics. Repairs may only be carried
out at the manufacturer’s factory.
After successful installation and
commissioning, instruct users in the
ventilation unit.