18 Wiring diagram for building control technology | UK
37
18 Wiring diagram for building
control technology
– circuit board A2 –
A
Ventilation unit
A1 Electronic slide-in module
A2 Controlled domestic ventilation
unit control
If the setting “
simple control unit
” is
changed to “
digital
”, the controlled
domestic ventilation unit can be con-
trolled using a switching actuator (e.g.
KNX). This allows the controlled do
-
mestic ventilation unit to be integrated
in a building control technology. The
actuator’s potential-free contacts must
be configured for switching 12 VDC.
Ethernet
USB
A2
A
A1
X10
Digital
RS485
X11
X12
Sensoren
RLS
X13
3.
3S
DS
C
AB
12V
LD2
LD1
S1+
S2-
LD3
24V
24V
K1
K2
12VDC - Operating display
12VDC - Filter change display
12VDC - Fault message
Ventilation level
K1
K2
Off*
Reduced ventilation
Nominal ventilation
Intensive ventilation
Off
On
Off
On
Off
Off
On
On
* In the "Ventilation level Off blocked"
setting, the device runs in the humidity
protection ventilation level.