34
UK | 15 Wiring diagram for external sensors
15 Wiring diagram for external
sensors – circuit board A2 –
A
Ventilation unit
A1
Electronic slide-in module
A2
Controlled domestic ventilation unit control
CO2 CO
2
sensor (
accessories)
VOC air quality controller (
accessories)
r.h.
Humidity sensor (
Accessories)
T-S
Intermittent ventilation button / external poten-
tial-free contact
W8
Connecting cable (provided by customer) for
external VOC sensor, e.g. LIYY 3 x 0.5 mm²
W8’
Connecting cable (provided by customer) for
external r.h. sensor 1, e.g. LIYY 3 x 0.5 mm²
W8”’ Connecting cable (provided by customer) exter-
nal button/potential-free contact (Function
intermittent ventilation/sensor type = digital),
e. g. LIYY 2 x 0.5 mm²
W9
Connecting cable (provided by customer) for
external CO
2
sensor 2, e.g. LIYY 3 x 0.5 mm²
W10 Connecting cable (provided by customer) for
external sensor 3, e.g. LIYY 3 x 0.5 mm²
W11 Connecting cable (provided by customer) for
external sensor 4, e.g. LIYY 3 x 0.5 mm²
The control’s sensor inputs can be freely
parametrised. The inputs are not defined for a
particular sensor type.
When commissioning a sensor, the sensor
input on the control must be activated and
the sensor type specified
Commissioning
and maintenance instructions. If the RLS 1 WR
on the controller is deactivated (parameter for
simple control unit inactive), up to 4 sensors
can be connected.
The power supply to
sensors 3 + 4 can be ensured via terminals
LD1, LD2, LD3 (all 12 VDC) or with double
assignment, via the 24 VDC supply of sensor
connections.