UK | 7 Safety instructions and warnings
Risk of injury and risk to health from
parts which may affect the ventilation
system which are added or modified at a
later date.
Parts (range hood, air-ventilated fireplace
etc.) which are added or modified at a later
date may result in health risks and operation
which is not permitted. Parts may only be
added or modified at a later date if system
compatibility is established/ensured by a
planning office. If using an exhaust air range
hood or air-ventilated fireplace, this must be
accepted by a professional chimney sweep.
Risk when using accessory compo-
nents which have not been approved.
The ventilation unit is tested and approved
with original accessory components.
Retrofitting (bypass, PTC heat register,
heat exchanger
etc.) is only permitted with original compo
-
nents.
Note space needed for additional compo-
nents (tubular sound absorber, supplementary
heating etc.).
Other modifications and alterations to the
unit are not permitted and release the manu-
facturer from any guarantee and liability.
Risk of injury from damaged ventila-
tion units.
Switch the ventilation units
off immediately
if you discover damage or faults that could
endanger persons or property.
Prevent the unit from being switched back
on until it has been fully repaired.
Danger of electric shock.
Before removing the front cover and
installing the electrics, switch off all supply cir
-
cuits and secure them against being acciden
-
tally switched back on again. Attach a warning
sign in a clearly visible place.
Danger from electric shock, fire or
short-circuiting when failing to comply
with the relevant regulations for electrical
installations.
Do not perform any tasks on live parts.
Be sure to observe the relevant regulations
for electrical installation; e.g. DIN EN 50110-1.
In Germany, particularly observe VDE 0100,
with the corresponding sections.
Comply with the electrotechnical safety
regulations (disconnect from voltage, secure
against being accidentally switched back on,
ensure de-energisation and cover or block off
neighbouring live components.
A mains isolation device with contact
openings of at least 3 mm at each pole is
mandatory.
Only connect the unit to a permanent elec
-
trical installation.
The unit may only be operated using the
voltage and frequency shown on the rating
plate.
Make electrical connections according to
wiring diagram.
Avoid touching components.
Maintenance and fault finding only permis
-
sible when carried out by trained electricians.
Risk of injury from running fans when
removing the front cover.
Before removing the front cover, wait until
both fans have stopped.
Danger of burning from hot housing
parts on units with PTC heat register
when removing the front cover.
After removing the front cover, do not touch
the heat register. First wait until the heat reg
-
ister and the housing parts have cooled off.
Risk of death from toxic air nearby
containing pollutants (smoke, va-
pours) in the event of a fire or chemicals
accident etc.
Switch the entire ventilation system off
immediately until the outside air is safe again.