WIRING DIAGRAM

WS 170 KR

Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 7

WS 170 ventilation unit with hygrostat and RLS 1 WR or RLS D1 WR room air con-
trol

W 1

G

N

Y

E

B

U

B

N

P E

N

L

W 4

A

B

W 2

W 2 '

I I

I

I I I

B 1

8

9
10

C O 2

B D E
O N / O F F

6

7

J u m p e r

1

A 2

2 3

1

r F >

r . F .

C O 2

A - WS 170 electronic slide-in module
A2 - Control circuit board: Jumper 8 bridged and jumper 10 (CO2) = open (= factory setting)
B - RLS D1 WR room air control
B1 - RLS 1 WR rH room air control HY 5 or HY 5 I hygrostat
W1 - 230 V AC connection cable
W2, W2´ - Control cable for room air control
W4 - Connection cable for external hygrostats (to be supplied by the customer). Connection to A2 control circuit board
at CO2 terminals
When connecting a hygrostat with potential-free contact for demand-driven removal of moisture, the hygrostat must
have a potential-free switching output.
The hygrostat always switches the ventilation unit to ventilation level 3 if the set humidity value is exceeded (poten-
tial-free contact in hygrostat closes).
If the humidity in the room drops, the ventilation unit switches back to the previously selected ventilation level.
If you switch manually from ventilation level 3 to level 2 or 1, this deactivates the automatic function of the hygrostat
temporarily. This is then switched back to active if the level drops below the hygrostat set point once.
Connect the hygrostat to terminal "CO2".
Jumper 10 on the A2 control circuit board must be open.
Set the switching point at the hygrostat manually.
Never connect a hygrostat and a CO2 sensor/VOC sensor at the same time.

Содержание WS 170 KR

Страница 1: ...1 N N e t z Z u l u f t N L 1 L 1 N L 1 L 1 N 1 2 3 4 5 6 7 8 9 1 0 CO2 BDE On Off Temp WH RD YE BU WH RD YE BU GNYE BU BN BN BU GNYE BN GNYE BU WH BU A2 0 10V BK T y p M1 J u m p e r a n z e i g e B...

Страница 2: ...tilation level 3 Jumper settings J 1 3 Unit type 000 WS 170 J 4 5 Frost protection temperature J 6 No function J 7 Jumper 7 open Ventilation level 3 is reset after an hour J 8 RLS 1 WR or RLS D1 WR ro...

Страница 3: ...2 BN GY YE GN PK WH B1 II I III LD3 LD2 LD1 S1 S2 B2 BN GY YE GN PK WH W2 BN WH PK GY GN YE A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B1 1 RLS 1 WR...

Страница 4: ...ons without giving prior notice Page 4 WS 170 ventilation unit with RLS D1 WR room air control 8 9 10 CO2 BDE ON OFF 6 7 Jumper 1 A2 A W1 W2 W H B N B G N Y E B U B N PE N L A WS 170 electronic slide...

Страница 5: ...B RLS D1 WR room air control B1 RLS 1 WR room air control H1 Display element e g glow lamp to be supplied by the customer W1 230 V AC connection cable W2 W2 Control cable for room air control W3 Cabl...

Страница 6: ...umper 8 bridged factory setting Jumper 10 bridged sensor is detected B RLS D1 WR room air control B1 RLS 1 WR room air control CO2 SKD CO2 sensor VOC EAQ 10 2 air quality controller W1 230 V AC connec...

Страница 7: ...pplied by the customer Connection to A2 control circuit board at CO2 terminals When connecting a hygrostat with potential free contact for demand driven removal of moisture the hygrostat must have a p...

Страница 8: ...nic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control B1 RLS 1 WR room air control P Differential pressure controller with potential free relay con...

Страница 9: ...ory setting B RLS D1 WR room air control B1 RLS 1 WR room air control GW1 Gateway frost protection heat register GW2 Gateway bypass shutter only WS 170 bypass unit T1 Supply air temperature sensor in...

Отзывы: