WIRING DIAGRAM

WS 170 KR

Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 3

WS 170 ventilation unit with RLS 1 WR room air control

O

T

LD

2

O

T

S

2

S

1

LD

3

LD

1

8

9
10

6

7

1

J u m p e r

W 1

G

N

Y

E

B

U

B

N

P E

N

L

A 2

A

C O 2

B D E
O N / O F F

G

N

Y

E

G

Y

B

N

W

H

P

K

L D 3
L D 2
L D 1
G N D
S 1 +
S 2 -

V

I I

I

I I I

L D 3

L D 2

L D 1

S 1 +

S 2 -

B N

G Y

Y E

G N

P K

W H

B 1

I I

I

I I I

L D 3

L D 2

L D 1

S 1 +

S 2 -

B 2

B N

G Y

Y E

G N

P K

W H

W 2 '

B N

W H

P K

G Y

G N

Y E

A - WS 170 electronic slide-in module
A2 - Control circuit board: Jumper 8 bridged (= factory setting)
B1 - 1 RLS 1 WR room air control
B2 - 2. RLS 1 WR room air control
W1 - 230 V AC connection cable
W2' - Control cable for room air control
V - Distributor (supplied by the customer)
You can connect up to 5 RLS 1 WR room air controls to the ventilation unit. If several room air controls are used, no
CO2 sensor may be connected.
Room air control RLS 1 WR can also be connected to room air control RLS D1 WR.
No need for distributor "V" if only one RLS 1 WR room air control is connected.

Содержание WS 170 KR

Страница 1: ...1 N N e t z Z u l u f t N L 1 L 1 N L 1 L 1 N 1 2 3 4 5 6 7 8 9 1 0 CO2 BDE On Off Temp WH RD YE BU WH RD YE BU GNYE BU BN BN BU GNYE BN GNYE BU WH BU A2 0 10V BK T y p M1 J u m p e r a n z e i g e B...

Страница 2: ...tilation level 3 Jumper settings J 1 3 Unit type 000 WS 170 J 4 5 Frost protection temperature J 6 No function J 7 Jumper 7 open Ventilation level 3 is reset after an hour J 8 RLS 1 WR or RLS D1 WR ro...

Страница 3: ...2 BN GY YE GN PK WH B1 II I III LD3 LD2 LD1 S1 S2 B2 BN GY YE GN PK WH W2 BN WH PK GY GN YE A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B1 1 RLS 1 WR...

Страница 4: ...ons without giving prior notice Page 4 WS 170 ventilation unit with RLS D1 WR room air control 8 9 10 CO2 BDE ON OFF 6 7 Jumper 1 A2 A W1 W2 W H B N B G N Y E B U B N PE N L A WS 170 electronic slide...

Страница 5: ...B RLS D1 WR room air control B1 RLS 1 WR room air control H1 Display element e g glow lamp to be supplied by the customer W1 230 V AC connection cable W2 W2 Control cable for room air control W3 Cabl...

Страница 6: ...umper 8 bridged factory setting Jumper 10 bridged sensor is detected B RLS D1 WR room air control B1 RLS 1 WR room air control CO2 SKD CO2 sensor VOC EAQ 10 2 air quality controller W1 230 V AC connec...

Страница 7: ...pplied by the customer Connection to A2 control circuit board at CO2 terminals When connecting a hygrostat with potential free contact for demand driven removal of moisture the hygrostat must have a p...

Страница 8: ...nic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control B1 RLS 1 WR room air control P Differential pressure controller with potential free relay con...

Страница 9: ...ory setting B RLS D1 WR room air control B1 RLS 1 WR room air control GW1 Gateway frost protection heat register GW2 Gateway bypass shutter only WS 170 bypass unit T1 Supply air temperature sensor in...

Отзывы: