WIRING DIAGRAM

WS 170 KR

Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 2

A - WS 170 ventilation unit
A1 - Electronic slide-in module
A2 - Control circuit board
A3 - Frost protection heat register
B - RLS D1 WR room air control
B1 - RLS 1 WR room air control
W1 - 230 V AC connection cable
W2 - Shielded control cable provided by customer, e.g. LiYCY 2 x 0.75 mm² for RLS D1 WR room air control; instead
of B1 (RLS 1 WR) room air control, B1 (RLS D1 WR) room air control can be connected.
W2´ - Control cable (provided by customer) for RLS 1 WR room air control outer diameter of control cable 3.2...6.5
mm, e.g. LIYY 6x0.34 mm²
S1 - Unit switch
GW1 - Gateway frost protection heat register
M1 - Supply air fan
M2 - Exhaust fan
S - Door contact switch: activated by front plate
T-min - Frost protection temperature sensor
Supply air
Z1 (blue) - potentiometer adjuster, ventilation level 1
Z2 (blue) - potentiometer adjuster, ventilation level 2
Z3 (blue) - potentiometer adjuster, ventilation level 3
Exhaust air
A1 (red) - potentiometer adjuster, ventilation level 1
A2 (red) - potentiometer adjuster, ventilation level 2
A3 (red) - potentiometer adjuster, ventilation level 3
Jumper settings
J 1-3 - Unit type, 000 = WS 170
J 4-5 - Frost protection temperature
J 6 - No function
J 7 - Jumper 7 open: Ventilation level 3 is reset after an hour.
J 8 - RLS 1 WR or RLS D1 WR room air control active: Leave factory setting, J8 must be bridged.
J 9 - Jumper 9 open: The ventilation unit can be switched off at the room air control. Jumper 9 bridged: RLS 1 WR:
Switch-off function blocked RLS D1 WR: Ventilation unit runs in "Humidity protection ventilation" mode when in the
OFF switch position.
J 10 - HY 5 or CO2/VOC sensor: Without a sensor, jumper 10 must be open. Jumper 10 open: Hygrostat released
with potential-free contact. Jumper 10 bridged: CO2/VOC sensor (0 to 10 V output) released.
Further connection options
W3 Connection cable (provided by customer) for external operating display.
k1 - Potential-free relay contact (max. 3A / 250 VAC, 2A / 30 VDC). The contact is closed when the ventilation unit is
running.
W4 - Connection cable (provided by customer) for external CO2 sensor or external hygrostat (hygrostat with poten-
tial-free contact).
W5 -Connection cable (provided by customer) for external differential pressure controller. Differential pressure con-
troller with potential-free relay contact. Minimum switching capacity of relay contact: 230VAC/2A. Remove J1 bridge
on A2 control circuit board.
W6 - Connection cable (provided by customer) for external supply air temperature sensor. Sensor type=NTC 10k. Re-
move 12k resistor on GW1 circuit board.

Содержание WS 170 KR

Страница 1: ...1 N N e t z Z u l u f t N L 1 L 1 N L 1 L 1 N 1 2 3 4 5 6 7 8 9 1 0 CO2 BDE On Off Temp WH RD YE BU WH RD YE BU GNYE BU BN BN BU GNYE BN GNYE BU WH BU A2 0 10V BK T y p M1 J u m p e r a n z e i g e B...

Страница 2: ...tilation level 3 Jumper settings J 1 3 Unit type 000 WS 170 J 4 5 Frost protection temperature J 6 No function J 7 Jumper 7 open Ventilation level 3 is reset after an hour J 8 RLS 1 WR or RLS D1 WR ro...

Страница 3: ...2 BN GY YE GN PK WH B1 II I III LD3 LD2 LD1 S1 S2 B2 BN GY YE GN PK WH W2 BN WH PK GY GN YE A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B1 1 RLS 1 WR...

Страница 4: ...ons without giving prior notice Page 4 WS 170 ventilation unit with RLS D1 WR room air control 8 9 10 CO2 BDE ON OFF 6 7 Jumper 1 A2 A W1 W2 W H B N B G N Y E B U B N PE N L A WS 170 electronic slide...

Страница 5: ...B RLS D1 WR room air control B1 RLS 1 WR room air control H1 Display element e g glow lamp to be supplied by the customer W1 230 V AC connection cable W2 W2 Control cable for room air control W3 Cabl...

Страница 6: ...umper 8 bridged factory setting Jumper 10 bridged sensor is detected B RLS D1 WR room air control B1 RLS 1 WR room air control CO2 SKD CO2 sensor VOC EAQ 10 2 air quality controller W1 230 V AC connec...

Страница 7: ...pplied by the customer Connection to A2 control circuit board at CO2 terminals When connecting a hygrostat with potential free contact for demand driven removal of moisture the hygrostat must have a p...

Страница 8: ...nic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control B1 RLS 1 WR room air control P Differential pressure controller with potential free relay con...

Страница 9: ...ory setting B RLS D1 WR room air control B1 RLS 1 WR room air control GW1 Gateway frost protection heat register GW2 Gateway bypass shutter only WS 170 bypass unit T1 Supply air temperature sensor in...

Отзывы: