
54
UK | 10 Radio-controlled operation with PP 45 units (EnOcean)
10.1 Meaning of the LEDs on
PP 45 RC/PPB 30 RC
LED
Meaning
Or
-
ange
LED flashes x times when the heat
recovery (WRG) operating mode is
selected (x = selected ventilation
level). When demand-driven oper
-
ation is selected, the LED lights up
for 5 sec.
Blue
LED flashes x times when the
cross-ventilation operating mode is
selected (x = selected ventilation
level). When demand-driven oper
-
ation is selected, the LED lights up
for 5 sec.
In exhaust air mode (PPB 30 RC),
the LED lights up 2x for 2 seconds.
Red
Filter change display and fault
indicator light.
10.2 Radio components which can be
learned-in (EEP)
i
PP 45/PPB 30 radio components must
support the EEP protocol. Radio com-
ponents with the EEP no. listed below
can be combined with the PP 45/
PPB 30 system.
Type
EEP
DS 45 RC radio switch,
4-channel wall transmitter
F6-02-01
Humidity/temperature sensor*
A5-04-01
CO
2
/temperature sensor
A5-09-08
VOC/temperature sensor**
A5-09-05
PP 45 Act: 1-channel re
-
cessed-mounted switch
D2-01-01
* Not available for PPB 30 units.
** No EnOcean VOC sensor currently
available.
i
If within range, up to 8 radio sensors
can be used with radio-controlled
systems.
i
Radio actuator PP 45 Act (
1 channel):
The PP 45 Act can be used to activate
the “Supply air for exhaust air units”
function for PP 45 RC units. The PP
45 Act is connected and learned-in
following the enclosed mounting and
operating instructions.
Learning-in tips
●
Radio components are learned-in directly on
the master PP 45 RC/PPB 30 RC (LEARN
key).
● Only one slave unit can be assigned to each
master ventilation unit of the same type.
Exception: For systems with PP 45 RC unit
pairs and PPB 30 RC, additional learning-in
of the PPB 30 RC in the PP 45 master is
possible.
●
Correct operation of a unit pair is monitored
by the master unit.
●
Learning mode is deactivated each time a
radio component is saved, meaning that it
has to be called up again for each further
component.
● If nothing is received within 120 seconds,
the learning-in process is ended (the LED
on the ventilation unit switches off).
●
Learn-in telegrams from non-supported
units are ignored.
10.3 Learn-in PP 45 Act EnOcean wire-
less actuator
With the PP 45 Act EnOcean actuator, radio-
controlled PP 45 RC PushPull units can be
combined with wired exhaust air units (ECA,
ER).