6 Requirements of the installation site | UK
33
6 Requirements of the installation
site
●
Ambient temperature - 15 °C to + 40 °C.
● Airstream temperature max. 40 °C.
● Max. permissible humidity in installation
room 70 % (at 20 °C).
●
A level and solid wall surface is needed for
wall installations.
● For filter changes, ensure sufficient space to
work in front of the unit.
●
Do not drill core drill hole for unit assembly
and do not drill fixing points on external and
internal covers in load-bearing components,
such as in the lintel or ring beam
7 Technical data
External diameter
Ø 160
Wall sleeve max. length
500 or 800 mm
Wall thickness min.
max.
265 mm
490 or 790 mm
Air filter outside
Air filter inside
G3
G2
Air volume/unit
42 m³/h
Protection class
Degree of protection
II
IP 00
Sound pressure level,
distance 1 m, free-field
conditions (ventilation
level 1 to 5)
23 / 28 / 33 /
37 / 40 dB(A)
Rated voltage/
power frequency
230 V
50/60 Hz
Volumetric flows for
ventilation level
1, 2, 3, 4, 5
15 / 20 / 30 /
36 / 42 m³/h
Power consumption
1.2 / 1.7 / 2.1 /
2.8 / 3.5 W
Weight
slide-in module cpl.
3 kg
Permissible ducting
lengths
with wired
connection
From star point
max. 25 m per
ventilation unit
Radio components:
Frequency range (in acc.
with EN 300220-1)
868.35 MHz
"Wireless" operating
distances in the building
are dependant on the
building materials used:
●
DS 45 RC
PP 45 RC
●
PP 45 EO
PP 45 RC
●
PP 45 RC
PP 45 RC
● With PP 45 RC as
signal booster
up to:
30 m
30 m
30 m
40 m