5 Application example
32
PPB 30 O
Operation with RLS 45 O or RLS 45 K
control.
PPB 30 K
with RLS 45 K control.
PPB 30 RC units
are operated using a DS 45 RC
radio switch (alternatively with RLS 45 K + radio
extension module PP 45 EO).
Not possible / not permissible:
● The operation of PPB 30 K units in combination
with an RLS 45 O control;
● A combination of PPB 30 K with exhaust air
units (e.g. ER…/ECA…);
● A combination of PPB 30 O and PP 45 O/K
units at the fan interface (Fan1/Fan2).
RLS 45 K
3 operating modes (heat recovery,
cross-ventilation, automatic mode), 5 ventilation
levels, time-limited intermittent ventilation, time-
limited switch-off, safety shutdown, ModBus, con-
figuration with PC (USB).
PP 45 EO
radio module
can be added to integrate radio sensors.
RLS 45 O
3 operating modes (heat recovery,
cross-ventilation, automatic mode), 5 ventilation
levels, configuration using service menu.
A
PPB 30
external cover with integrated condens-
ate drain is required for installation with a wall
sleeve.
The fan/heat exchanger unit is designed as a duct
mounting and can be removed for repair and
cleaning purposes.
PPB 30
ventilation units are only intended for do-
mestic use and similar purposes. No other or ad-
ditional use is intended.
5 Application example
Ventilation solution for a 3-room flat with PPB
30 K
ventilation units
for the
bathroom
and
PP
45
ventilation units for
living spaces
The
PPB 30
in the bathroom ventilates and ex-
tracts air from the room, at the same time, in bal-
anced mode. A fan in the unit extracts air and first
transfers the exhaust air heat to the heat storage
tank. Another fan in the unit pumps the supply air
into the room across the heat storage tank, which
gives off this heat. Every 60 seconds, the air dir-
ection changes, thereby permitting a ventilation
mode with constant heat recovery.
Intensive ventilation can be activated via a humid-
ity sensor or manually with a button if the humidity
is high and/or if the air quality is inadequate.
Pure exhaust air mode is also possible and here
the two fans pump out humidity (no heat recov-
ery).
Combined with
PP 45
single-room ventilation
units for supply air rooms, a decentralised ventila-
tion system for flats can also be produced for re-
development projects.
The
PP 45
units ensure an increased supply of air
and therefore balanced ventilation, even if ex-
haust air mode is sometimes used.
Example:
Combination of
PPB 30 K
+
PP 45
units
1
PP 45 unit
with alternating operation for
continuous ventilation of living spaces
2
PPB 30 K unit
with balanced operation for
continuous ventilation in the bathroom
3
Room air control
RLS 45 K
Supply air and exhaust air with change of
direction
Outside and outgoing air with change of
direction
Содержание PPB 30 O
Страница 3: ...Steuerungskonzept PPB 30 3 Steuerungskonzept PPB 30...
Страница 4: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 4 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Страница 29: ...PPB 30 control concept 29 PPB 30 control concept...
Страница 30: ...PP 45 RC PPB 30 RC wireless control concept 30 PP 45 RC PPB 30 RC wireless control concept...
Страница 53: ...Concept de commande PPB 30 53 Concept de commande PPB 30...
Страница 54: ...Concept de commande PP 45 RC PPB 30 RC radio 54 Concept de commande PP 45 RC PPB 30 RC radio...
Страница 95: ...Produktdatenbl tter Product data sheets Fiches techniques du produit 95 PPB 30 O...