6
Mounting information
PPB 30 AK, PPB 30 AE/AW,
PPB 30 ARE/ARW,
PPB 30 ARE BB/ARW BB
!
DANGER
This mounting information is
only valid in combination with
the PP 45/PPB 30 shell mount-
ing instructions. The safety
instructions listed there must
be read and followed.
1 Scope of delivery
●
External cover
PPB 30 AK/AE/AW:
Drilling template, this mounting information
or
●
Compensating frame
PPB 30 ARE/ARW:
Drilling template, this mounting information.
4 stainless steel flat-head screws M4x12
for attaching the PPB 30 AK/AE/AW or
PP 45 AK/AE/AW
or
●
Fixing plate
PPB 30 ARE BB/ARW BB:
4 stainless steel countersunk head screws
M4x8. Necessary for mounting on the com-
pensating frame PPB 30 AE/AW.
2 Intended use
●
PPB 30 compensating frame for mounting
on the wall sleeve (DN 162) if the wall thick-
ness is insufficient.
The wall sleeve must
have an incline of 1 to 2% to the external
wall.
For wall sleeve installation
shell
mounting instructions.
●
For
wall thicknesses < 320 mm
, use
a/several compensating frames PPB 30
ARE/ARW (each 55 mm deep). This is
important to achieve the prescribed
minimum wall thickness.
●
External cover PPB 30 AE/AW:
To mount the external cover on the com-
pensating frames, use the fixing plate
PPB 30 ARE BB/ARW BB.
It is impera-
tive to comply with the prescribed wall
sleeve projection from the external wall:
Projection = wall thi depth of the
PPB 30 AREs/ARWs + 5...10 mm.
●
The mounting of the
external cover
PPB 30 AK
on the compensating frame
PPB 30 ARE/ARW is done without fixing
plate.
3 Mounting
!
WARNING
Risk of injury in case of incorrect instal-
lation.
Only mount external cover/com-
pensating frame on walls with sufficient
load-bearing capacity and with suitable
mounting material.
!
CAUTION
Danger of injury when handling
housing parts with sharp edges,
e.g. stainless steel external covers.
Wear protective gloves.
●
Only mount external cover/compensating
frame once the external plastering is com-
plete.
●
Suitable mounting material is to be supplied
by the customer.
●
Formation of surface rust: External factors
(e.g. air containing sulphur dioxide or salt,
dust containing iron etc.) may cause surface
rust to form on stainless steel.
Recommen-
dation:
Thoroughly clean unpainted stain-
less steel external covers before mounting
(removal of dust and finger-prints) and rub
in a little oil (e.g. care oil for stainless steel).
●
Recommendation:
To prevent dirt from
depositing on the façade around the
external cover, fit a water-repellent plaster
system.