8 Radio-controlled operation (EnOcean)
58
• Just
one slave
ventilation unit can be taught-in
on
one master
.
Exception:
In systems with
PP
45 RC
and
PPB 30 RC
unit pairs, the additional
teaching-in of the
PPB 30 RC
into the
PP 45
RC
master is possible.
• No presettings are needed for master-slave op-
eration.
• A ventilation unit automatically becomes a
mas-
ter
if the master unit is set to
receive mode
and a
teach-in telegram
is received from a
slave unit
.
• A ventilation unit becomes a
slave unit
if this
slave transmits a
teach-in telegram
to the
master unit
and the master confirms it.
• If a
master unit
receives a valid
teach-in tele-
gram
from an
EnOcean component
that has
not yet been taught in, the data is evaluated
and stored.
• Set values are transferred from the master to
the slave in cycles, e.g. ventilation level, operat-
ing mode and sensor measurements. Data,
timer and changeover times are also trans-
ferred in cycles and the transfer confirmed.
• If the master does not receive a response from
the slave unit within a defined time, the unit pair
affected switches to fault.
• If the slave unit doesn't receive cyclic queries
from the master, it switches to fault. The faults
are displayed using LED flash code →
.
8.6.2 Teaching-in unit pairs
Determine a pair of devices, then teach the
slave ventilation unit into the master, then
teach-in the radio switch and radio sensors.
1. Remove the front cover on the ventilation
units.
2. Switch the
master ventilation unit (receiver)
into teach-in mode To do so, press the
TEACH button on the master for 2 seconds.
All 3 LEDs flash, teach-in mode is activated.
ð
Now, a teach-in telegram must be received
within 120 seconds or the teach-in mode is
terminated.
3. Activate the teach-in mode on the
slave vent-
ilation unit (transmitter)
. Press the TEACH
button here for 2 seconds. All 3 LEDs flash.
4. Switch
slave unit
into
send-teach mode
. To
do this, press TEACH button briefly 1x. The 3
LEDs on the slave flash once and then switch
off (periodic process).
5. Press TEACH button on the
slave
(> 2
seconds) until the LEDs on the slave briefly
light up once and then go out.
ð
The teach-in telegram is sent.
When a teach-in telegram is correctly re-
ceived, teach-in mode is exited by the receiver
and transmitter. If the master unit is still in
teach-in mode (3 LEDs flashing), the teach-in
telegram from the slave unit has not arrived →
Repeat process.
6. Before putting on the front cover of the
PP 45
RC
, the shutter must always be open. To do
this, switch on the
PP 45 RC
.
7. Fit front cover for internal housing on the units
such that it locks into the safety catches.
8. Run function test.
8.6.3 Teaching-in DS 45 RC radio switch
1. Remove the front cover on the
master unit
.
2. Switch the master ventilation unit (receiver)
into
teach-in mode
. To do so, press the
teach-in button
on the master for 2 seconds.
All 3 LEDs flash, teach-in mode is activated.
3. Press
Ventilation level rocker switch
1x.
The
teach-in telegram
is sent. Both buttons
are now taught-in. Once teaching-in has been
successfully completed, TEACH mode is ex-
ited.
4. Before putting on the front cover, the
shutter
must always be open
. To do this, briefly
switch on the master unit.
5. Fit front cover for internal housing on the mas-
ter unit such that it locks into the safety
catches.
6. Run function test.
8.6.4 Teaching-in radio sensor
1. Remove the front cover on the master unit.
2. Switch the master unit (receiver) to
teach-in
mode
. To do so, press the TEACH button on
the master for 2 seconds. All 3 LEDs flash,
teach-in mode is activated.
3. Send a
teach-in telegram
with the radio
sensor → Operating instructions of radio
sensor. Once teaching-in has been success-
fully completed, TEACH mode is exited.
4. Before putting on the front cover, the shutter
must always be open. To do this, briefly switch
on the master unit.
5. Fit front cover on the master unit such that it
locks into the safety catches.
Содержание PP 45 O
Страница 2: ...Inhaltsverzeichnis Deutsch 3 English 36 Fran ais 70...
Страница 4: ...bersicht PP 45 4 bersicht PP 45...
Страница 6: ...bersicht PPB 30 6 bersicht PPB 30...
Страница 8: ...Steuerungskonzept PP 45 8 Steuerungskonzept PP 45...
Страница 9: ...Steuerungskonzept PPB 30 9 Steuerungskonzept PPB 30...
Страница 10: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 10 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Страница 37: ...Table of contents 37 PP 45 RC 110 PPB 30 O 112...
Страница 38: ...Overview of PP 45 38 Overview of PP 45...
Страница 40: ...Overview of PPB 30 40 Overview of PPB 30...
Страница 42: ...PP 45 control concept 42 PP 45 control concept...
Страница 43: ...PPB 30 control concept 43 PPB 30 control concept...
Страница 44: ...PP 45 RC PPB 30 RC wireless control concept 44 PP 45 RC PPB 30 RC wireless control concept...
Страница 72: ...Vue d ensemble PP 45 72 Vue d ensemble PP 45...
Страница 74: ...Vue d ensemble PPB 30 74 Vue d ensemble PPB 30...
Страница 76: ...Concept de commande PP 45 76 Concept de commande PP 45...
Страница 77: ...Concept de commande PPB 30 77 Concept de commande PPB 30...
Страница 78: ...Concept de commande PP 45 RC PPB 30 RC radio 78 Concept de commande PP 45 RC PPB 30 RC radio...
Страница 105: ...105 PP 45 PPB 30 Volumenstr me PP 45 PPB 30 volumetric flows D bits d air PP 45 PPB 30...
Страница 106: ...106...
Страница 107: ...107...
Страница 108: ...108 PP 45 O PP 45 K PP 45 O PP 45 K PP 45 O PP 45 K...
Страница 109: ...109 PP 45 O PP 45 K mit PP 45 HYI PP 45 O PP 45 K with PP 45 HYI PP 45 O PP 45 K avec PP 45 HYI...
Страница 110: ...110 PP 45 RC PP 45 RC PP 45 RC...
Страница 111: ...111 PP 45 RC mit PP 45 HYI PP 45 RC with PP 45 HYI PP 45 RC avec PP 45 HYI...
Страница 112: ...112 PPB 30 O PPB 30 O PPB 30 O...
Страница 114: ......
Страница 115: ......