Montage- und Betriebsanleitung EVN 22, EVN 22 R
Installation and operating instructions for EVN 22, EVN 22 R
Notice de montage et mode d'emploi EVN 22, EVN 22 R

EN

6

Maico Elektroapparate-Fabrik GmbH 

I

 Steinbeisstr. 20 

I

 78056 Villingen-Schwenningen 

I

 Germany 

www.maico-ventilatoren.com

 

I

 S49 7720 6940 

I

 [email protected]

0185.0981.0006_RLF.9_07.23_DSW

Installation and operating instructions for EVN
22 and EVN 22 R window fans

Unit overview (Fig. A to H)

Inside of window

Window

Outside of window (with lamellae open +30 mm)

1

Shutter, complete

2

Flange sleeve with motor 2.1, impeller 2.2, servo-
motor (actuator) 2.3

3

Inner housing (= cover)

4

Terminal box cover

5

Gluing point

6

Screw (M5 x 50)

7

Connection cable of EVN 22 R shutter

8

Lock nut

9

Socket spanner (width across flats 8, red)

10

Tension relief

11

Terminal block 3-pole or 7-pole

12

Sealing

L

Power cable

P

Production date (stamp)

S

Window cut-out, alternatively wall cut-out

T1, T2 Cable grommet

Y

Flange sleeve knockout points

Z

Shutter knockout points

Table of contents

1

Scope of delivery................................................

6

2

Safety ................................................................

6

2.1

General safety instructions .........................

6

2.2

Safety instructions regarding installation,
operation, cleaning and maintenance ........

6

3

Intended use......................................................

7

4

Unit variants ......................................................

7

5

Overload protection...........................................

7

6

Technical data....................................................

7

7

Installation.........................................................

7

7.1

Fig. A + B: Preparation for installation ........

7

7.2

Fig. C: Removing inner housing....................

7

7.3

Fig. D: Attaching the shutter ........................

7

7.4

Fig. E: Attaching flange sleeve .....................

7

7.5

Fig. F + G: Connecting the fan ......................

7

7.6

EVN 22 R: Operation with 5-step trans-
former ..........................................................

8

8

Commissioning ....................................................

8

9

Cleaning ..............................................................

8

10 Maintenance .......................................................

8

11 Fault rectification ................................................

8

12 Spare parts ..........................................................

8

13 Dismantling and environmentally sound dis-

posal ...................................................................

8

Company information..........................................

8

Circuit diagrams................................................... 14

1 Scope of delivery

Flange sleeve with socket spanner, inner housing, shutter.
Accessory bag with 4 screws (M5 x 50), 4 lock nuts, tension
relief and cable grommet. These installation and operating
Instructions.

2 Safety

Please read the instructions carefully before installing,
commissioning and using. Follow the instructions. Observe
the 

safety instructions 

and the technical data. Pass these

instructions on to the owner for safekeeping.

Specialist installers, qualifications, requirements

The fan may only be installed, set up, retrofitted, commis-
sioned, cleaned, serviced or repaired by 

installers special-

ised in ventilation technology

. Electrical connection, com-

missioning, maintenance and repairs may only be carried
out by a 

qualified electrician

 in accordance with DGUV

regulation 3, Section 2 (3) and in compliance with the rel-
evant standards (e.g. DIN EN 50110-1) and technical rules.
Further provisions of other national laws must be taken
into account.

Qualifications, requirements:

 Specialist training and know-

ledge of compulsory technical standards, EU Directives and
EU Ordinances. The installations must be carried out pro-
fessionally. Applicable accident prevention regulations, oc-
cupational health and safety measures (protective clothing
in good repair etc.) must be observed. Installation work by
trainees is only permitted under the supervision of the
above-mentioned trained specialists.

2.1 General safety instructions

 DANGER Risk of combustion/fire from flammable

materials, liquids or gases in the vicinity of the unit.

Do not place any flammable materials, liquids or gases
near the unit, which may ignite in the event of heat or
sparks and catch fire.

 DANGER Explosive gases and dust may ignite and

cause serious explosions or fire.

Never use fan unit in an explosive atmosphere (risk of ex-
plosion).

 WARNING Risk to health from chemicals or aggress-

ive gases/vapours.

Chemicals or aggressive gases/vapours may harm health,
especially if they are distributed throughout the rooms by
the unit.
Never use unit to distribute chemicals or aggressive gases/
vapours.

NOTICE Damage to unit due to grease and oil vapours
from range hoods.

Grease and oil vapours from range hoods may contamin-
ate the unit and air ducts and reduce efficiency.
Never use unit to convey these substances.

NOTICE Damage to the device, functional impairment.

Never use the fan in hinged double-glazed windows, on
ceilings, sloping roofs or sloping walls. Do not dismantle
the shutter under any circumstances.

2.2 Safety instructions regarding installation, oper-
ation, cleaning and maintenance

 DANGER Risks for children and people with reduced

physical, sensory or mental capabilities or a lack of know-
ledge.

Unit may only be installed, commissioned, cleaned and
maintained by persons who can safely recognise and avoid
the risks associated with this work.

 WARNING Risk of injury due to suction from unit

and rotating impeller.

Hair, clothing, jewellery etc. may be pulled into the unit if
you get too close to it.
During operation, always keep far enough away to prevent
this from happening.

 WARNING Risk of injury if foreign objects are inser-

ted into the unit.

Do not insert any objects in the unit.

 WARNING Risk of injury from glass breakage/cutting

injuries if the pane is damaged.

Handle glass components with care during mounting,
maintenance and repair work. Comply with accident pre-
vention regulations.

 CAUTION Risk during transport due to falling loads.

Observe applicable safety and accident prevention regula-
tions. Do not stand under a suspended load. Check unit for
transport damage. Do not commission a damaged unit.

NOTICE

Fan operation is only permissible with correct installation
position and with correctly fitted covers (protection
against accidental contact with the impeller according to
DIN EN ISO 13857).

NOTICE Health risk due to deposits on the unit (mould,
bacteria, dust etc.).

Clean fan at regular intervals, especially after the fan has
not been used for a long time.

 WARNING Risk of injury and health risk in the event

of changes or modifications or if components which are
not permitted are used.

The unit may only be operated with original components.
Changes and modifications to the units are not permitted
and release the manufacturer from any guarantee obliga-
tions and liability, 

e. g. if the housing is drilled at a point

which is not permitted

.

 WARNING Risk of injury when working at heights.

Use appropriate climbing aids (ladders).
Stability should be ensured, if necessary have the ladders
steadied by a 2nd person.
Ensure that you are standing securely and cannot lose
your balance and that there is no one under the unit.

 WARNING Danger of electric shock when operating

a fan which is damaged or not fully mounted.

Before taking off the terminal box cover, shut down all
supply circuits (switch off mains fuse), secure against be-
ing accidentally switched back on and position a visible
warning sign. Only operate the fan when it is completely
installed. Do not commission a damaged unit.

Содержание EVN 22

Страница 1: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R DE 1 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Страница 2: ...ien Fl ssigkeiten oder Gase in der N he des Ger ts In der N he des Ger ts keine brennbaren Materialien Fl ssigkeiten oder Gase deponieren die sich bei Hitze oder durch Funkenbildung entz nden und in B...

Страница 3: ...d angebrachtem Innenge h use Diese Ventilatoren sind ausschlie lich f r den h uslichen Gebrauch und hnliche Zwecke vorgesehen Eine andere oder dar ber hinausgehende Benutzung gilt als nicht be stimmun...

Страница 4: ...pe die Lamellen nach oben schwenken Zum Reinigen kein aggressives ge sundheitssch dliches oder leicht entflammbares Reinigungsmittel verwenden 3 Innengeh use anbringen 10 Wartung Bei Standardbetrieb i...

Страница 5: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R EN 5 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Страница 6: ...any flammable materials liquids or gases near the unit which may ignite in the event of heat or sparks and catch fire DANGER Explosive gases and dust may ignite and cause serious explosions or fire N...

Страница 7: ...c tifying the fault the fan can restart automatically 6 Technical data Ambient conditions Permissible maximum temperature of air medium 40 C Sufficient supply air intake must be ensured during oper at...

Страница 8: ...re it against being switched on again Have the connection cable replaced by a trained specialist 11 Fault rectification Fault finding and repairs only permissible when carried out by qualified electri...

Страница 9: ...22 EVN 22 R Notice de montage et mode d emploi EVN 22 EVN 22 R FR 9 Maico Elektroapparate Fabrik GmbH I Steinbeisstr 20 I 78056 Villingen Schwenningen I Germany I www maico ventilatoren com I Service...

Страница 10: ...ormes techniques des directives et ordonnances de l UE sont prescrites Les ins tallations doivent tre r alis es dans les r gles de l art Les consignes de pr vention d accident en vigueur les me sures...

Страница 11: ...arable dans lesquels sont install s des foyers d pendant de l air ambiant que si des dispositifs de s curit emp chent le fonctionne ment simultan de foyers d pendant de l air ambiant pour des combusti...

Страница 12: ...r conform ment au sch ma de branchement autocol lant dans la bo te bornes ou chapitre Sch mas de branchement 14 Pour EVN 22 R raccorder en plus le c ble de raccordement du volet ext rieur 2 Raccorder...

Страница 13: ...hwenningen Allemagne T l 49 7720 694 445 Fax 49 7720 694 175 E mail ersatzteilservice maico de 13 D montage et limination dans le respect de l environnement Les appareils usag s et composants lectriqu...

Страница 14: ...lectrique ext rieur S1 marche arr t S2 Commutation insufflation vacuation d air bornes 4 et 5 insufflation vacuation d air EVN 22 R FS6 FS7 Elektrische Verschlussklappe au en S1 Ein Aus S2 Umschaltung...

Отзывы: