11 Wiring diagrams
8
5. Run function test: Test all unit functions (over-
run time, interval, humidity control etc.)
For ER-A, no setting functions. For ER-AK,
ER-AH, ER-AB, the operating parameters
can be changed.
6. Fold down the upper part of the cover (upper
part must audibly engage).
11 Wiring diagrams
Cut off and insulate PE conductor and individual cable cores that are not required
Nominal load can be
switched without base load
Nominal load can be
switched with permanent
base load
Nominal load and base load
can be switched
Please tick the connection variant
Nominal load switchable with
2 cable cores*
Base load switchable with 2
cable cores*
*If the units are connected with 2 cable cores
(nominal load switchable with 2 cable cores, base
load switchable with 2 cable cores), the ER-A
cover is to be used. The ER-AK, ER-AH and ER-
AB covers require a permanent electrical connec-
tion.
12 Dismantling
Dismantling is only permissible by persons with
electrical training.
13 Environmentally responsible
disposal
Once they are no longer needed, packaging ma-
terials and used units should be disposed of in
compliance with local regulations. Do not dispose
of old units in the normal household waste.