12. Installation 

‒ ER

-

UP/GH ‒ second room

22 

11  Installation socket for second room 

extraction Ø 75 / Ø 80 

12  Adapter 
13  Filter mat, filter class G2 
14  Protective grille 
15  Suction duct, second room connection:  

flexible aluminium duct AFR 75/AFR 80 

37  UPM 60/100 mounting support 
40  Expanded rubber ER-MO 

X4  Clamping band or steel threaded rod 

with pipe clamp 

 chapter 11.3 

12.1.7 Ceiling installation ER-

UP/GH ‒ 

second room 

Observe mounting information in chapter 

12.1.2. 
1. Mount ER-UP/GH housing on ceiling as

described in chapter 12.1.5.

2. Mount second room connection ER-ZR on

ceiling as described in chapter 12.1.6. 

Secure ER-UP housing and the 

connection cable with 2 mounting 

supports [37] and/or clamping bands/ 

threaded rods each. 

Содержание ER 60 E

Страница 1: ...ИНСТРУКЦИЯ Maico ER 100 EH ...

Страница 2: ...Mounting and operating instructions Recess mounted exhaust air system according to DIN 18017 3 ER UP GH ER 60 E ER 100 E www m aico ventilatoren c om DE ...

Страница 3: ...2 1 ...

Страница 4: ...0 7 3 Possible combinations 10 8 Environmental conditions and operating limits 12 8 1 Regulations for operation with fireplaces 12 9 Technical data 12 10 Storage 12 11 Mounting preparations 13 11 1 Installation specifications for ER UP GH with ER 60 E or ER 100 E single room second room 13 11 2 Preparations for wall installation 14 11 3 Ceiling installation preparations 15 11 4 Preparations for th...

Страница 5: ...ssembly Fan insert ER 60 E ER 100 E Article no internet or catalogue Fan inserts with different control circuit boards depending on application Can be used in all ER UP GH recessed mounted housings Internal cover with exhaust air filter Other accessories Second room connection set ER ZR article no 0093 1025 Comprising protective grille filter mat adapter plastic exhaust socket and regulating plate...

Страница 6: ......

Страница 7: ... fans are used to extract air from interior bathrooms and toilet rooms storage rooms and kitchens with an outside window If operated other than stated in DIN 18017 3 the fans may also be used as standalone units fitted on the wall or ceiling or to extract air from other rooms interior kitchen etc These fans are only intended for domestic use and similar purposes 4 Non intended use These fans must ...

Страница 8: ...people with reduced physical sen sory or mental capabilities or a lack of knowledge Fan may only be installed commissioned cleaned and maintained by people who can safely recognise and avoid the risks associated with this work DANGER Risk to health if filters are not replaced or if there are no air filters Heavily contaminated or damp air filters may collect substances hazardous to health mould ge...

Страница 9: ... which are added or modified at a later date Parts range hood air ventilated fireplace etc which are added or modified at a later date may result in health risks and operation which is not permitted Parts may only be added or modified at a later date if system compatibility is established ensured by a planning office If using an exhaust air range hood or air ventilated fireplace this must be accep...

Страница 10: ... installation is undertaken correctly and if the connecting cable is correctly guided through the cable grommet The grommet must completely enclose the cable sheathing The fan insert must also be engaged and the housing cover installed DANGER of fire spreading In the event of a fire there is a risk of the fire spreading if an incorrect connecting cable is connected to the ER housing Always use the...

Страница 11: ...own Cool down time can be up to 10 minutes The fan switches back on automatically after cooling down 7 Product information The ER UP GH recess mounted housings are specified for ER recess mounted versions with ER 60 E or ER 100 E fan inserts Other ER UP housing types are not permitted for these fan inserts The connection diameter for ER UP GH housings is Ø 75 or Ø 80 7 1 Installation conditions If...

Страница 12: ......

Страница 13: ...ER 60 E or ER 100 E fan insert is placed in the UP GH housing the exhaust air filter and cover are fitted ER 100 E units are permitted for second room air extraction These can be combined with the standard EVZ or EG control models chapter 12 1 1 ER 60 units are not permitted for the second room connection 7 3 1 Recess mounted housing ER UP GH Plastic housing without fire protection equipment Can b...

Страница 14: ... described in chapter 22 Circuit board models EVZ model With start delay and overrun time EG model With base load circuit Continuous operation at 35 m h high speed full load can be switched with optional switch EH model Barrier free With humidity control fully automatic Overrun time controlled by program 15 minutes at full load Can also be operated manually with optional switch Not suitable for se...

Страница 15: ...ns for operation with fireplaces Sufficient supply air intake must be ensured during operation with air ventilated fireplaces The maximum permitted pressure difference per living unit is 4 Pa The fan may only be installed in rooms with air ventilated fireplaces if the evaluation criteria drawn up by the responsible regional master chimney sweep are met a parallel operation of air ventilated firepl...

Страница 16: ... ducts inside the shaft E g flexible aluminium duct AFR 80 between main duct in shaft and ER unit max 2 m long Connection ducts outside the shaft E g flexible aluminium duct AFR 80 between main duct in shaft and ER unit max 2 m long Duct elbows in the unit connection duct max 90 bend ascending Number of duct elbows permitted for wall installation max 2 x 90 Number of duct elbows permitted for ceil...

Страница 17: ...cold shrink tape Preparing the shaft 1 Produce opening in shaft or alternatively produce a wall facing Ensure a suitable flat surface for the ER UP housing so that the fan insert can be safely inserted in the housing later on 2 For a second room connection produce an opening in the wall or shaft for the suction duct 15 Note permissible housing installation positions 3 Correctly attach main ventila...

Страница 18: ......

Страница 19: ...eparations 15 Suction duct for second room connection on ER UP GH flexible aluminium duct AFR 75 AFR 80 18 Main duct Steel folded spiral seams duct 19 Connection duct on ER UP GH flexible aluminium duct AFR 75 AFR 80 20 Power cable Be sure to note the mounting information in chapter 11 2 Preparing the shaft and suspended ceiling 1 Produce an opening in the suspended ceiling fire resistance not sti...

Страница 20: ...s 3 of each 30 Dowel 30 1 Plastic dowel or anchor bolt 30 2 Metal expansion dowel 31 Retaining bolt with nut 32 Retaining bolt 33 Steel clamping band Be sure to note the mounting information in chapter 11 2 Duct attachment with duct clamp alterna tively duct attachment with clamping band Maintain a maximum distance of 1 5 m between the duct attachments 23 4 Correctly attach main ventilation duct 1...

Страница 21: ...tion a visible warning sign Notes Always note the relevant specifications for electrical installations and when fitting equipment In Germany observe DIN VDE 0100 and the corresponding parts in particular Observe ambient conditions and technical data chapters 8 and 9 Note permitted duct cross section of max 1 5 mm 1 Switch off mains fuse secure against being accidentally switched back on and positi...

Страница 22: ...e mounting material is to be supplied by the customer The plastic shutter should be prepared according to chapter 11 5 1 so that it closes fully sealed in the installation position The ER UP GH housing must be inserted without any warping Failure to do so will mean that the fan insert cannot engage correctly in the ER UP GH housing and the degree of protection stated on the rating plate is no long...

Страница 23: ...60 100 2 Cut the mounting support 37 to the required length bend it into shape and fix it to the ER UP GH housing with the supplied fixing screws 3 Mark fixing holes for mounting support on rear shaft wall produce holes and insert dowels Suitable mounting material is to be supplied by the customer DANGER Danger of short circuits and damage to the unit If the cable grommet 39 is not installed corre...

Страница 24: ......

Страница 25: ... the ER UP GH housing with the supplied fixing screws Fig 7 3 Mark fixing holes for mounting support and or ER UP GH housing on ceiling produce holes and insert dowels Suitable mounting material is to be supplied by the customer DANGER Risk of short circuits and damage to unit If the cable grommet 39 is not installed correctly water may penetrate the ER UP GH housing Protection class is not guaran...

Страница 26: ...ger guaranteed Lift up housing floor seal 5 near socket and insert installation socket 11 Re insert housing floor seal in the correct position 2 Place installation socket 11 in ER UP GH housing The edge of the socket must click into place on the wall of the housing 3 Install housing as described above for single room 4 Connect suction duct 15 with installation socket 11 sealed for ventilation 5 Pr...

Страница 27: ...g support 40 Expanded rubber ER MO X4 Clamping band or steel threaded rod with pipe clamp chapter 11 3 12 1 7 Ceiling installation ER UP GH second room Observe mounting information in chapter 12 1 2 1 Mount ER UP GH housing on ceiling as described in chapter 12 1 5 2 Mount second room connection ER ZR on ceiling as described in chapter 12 1 6 Secure ER UP housing and the connection cable with 2 mo...

Страница 28: ...ion terminals switch off all supply circuits Switch off mains fuse secure against being accidentally switched back on and position a visible warning sign DANGER Danger to life from electric shock The unit will be damaged if installed incorrectly with too long a power cable If the cable feed is too long inside the housing the fan insert cannot be in stalled correctly The power cable may be damaged ...

Страница 29: ...hapter 8 and technical data chapter 9 Note permitted duct cross section of max 1 5 mm Only connect the unit to a permanent electrical installation The degree of protection is only guaranteed if installation is undertaken correctly if the power cable is correctly guided through the intended cable grommet if fan unit is correctly engaged in ER UP housing and if cover 7 is closed and engaged 13 1 1 C...

Страница 30: ......

Страница 31: ...ad level 60 or 100 m h If there are no further increases the unit continues to run at nominal load level 1 until the humidity again falls below the saved reference value If the humidity falls below the saved reference value the overrun operation starts with an overrun time of 15 minutes If the humidity does not fall below the reference value within 60 minutes the unit switches back into the operat...

Страница 32: ...tly Ensure correct engagement in the 3 fixing points 43 and 44 As an option fix the fan insert 3 suitable fixing screws 42 Mounting information in unit 7 Slide fan insert exhaust air element evenly and in parallel onto both studs 44 Ensure that both locking tabs of the studs and the locking lever 43 engage audibly 8 Ensure that the fan insert is correctly engaged To do this gently pull and press a...

Страница 33: ... this with a two part wall frame ER MR can be adjusted between 50 100 mm This prevents air from being drawn in from the shaft Use the supplied screw to fix the cover 1 Fold up cover 7 at the recessed grip place on the ER UP housing and secure with the central screw 7 1 2 If necessary first fit a spacing or wall frame 3 With second room extraction insert regulating plate 9 below locking tabs at the...

Страница 34: ...h to clean the cover 7 of the fan 2 If the cover is very dirty remove it and clean with water 3 Fold up cover 7 4 Take out filter mat 10 and replace it 5 Place filter mat on intake grille cover 7 and lock cover The lock must engage audibly Filter change interval every 3 to 6 months depending on the degree of soiling Filter mats ZF 60 100 Pack of 5 filter class G2 in accordance with EN 779 Art no 0...

Страница 35: ...mbH Steinbeisstraße 20 78056 Villingen Schwenningen Germany Tel 49 7720 694 445 Fax 49 7720 694 175 Internet www ventilatorshop24 com E mail ersatzteilservice maico de 16 3 Removing fan insert 10 Fan insert 43 Locking lever 44 Studs 44 1 and 44 2 1 Switch off mains fuse secure and fit warning sign 2 Open cover 7 and remove 3 Press locking lever 43 slightly outwards arrow release and slightly lift ...

Страница 36: ......

Страница 37: ...must click into place on the wall of the housing CAUTION Damage to unit in the event of improper installation position of the housing floor seal Protection class is not guaranteed Lift up the housing floor seal before inserting the ER AS extraction socket and then reposition it correctly afterwards 3 Install ER UP GH housing unit in accordance with chapter 12 1 Note the descriptions relating to th...

Страница 38: ...nnect the fan as per the wiring diagram Fan doesn t start up Check whether the fan insert is correctly inserted Fault Cause measure Fan is too loud Dirty filter Replace filter Fan insert incorrectly installed Insert fan insert correctly in accordance with chapter 14 2 The main duct is undersized Re calculate pressure losses H model does not switch from base load to full load operation despite ther...

Страница 39: ... 20 Dismantling Dismantling may only be undertaken by a trained electrician chap 2 DANGER Danger to life from electric shock Prior to accessing the connection terminals switch off all supply circuits Switch off mains fuse secure against being accidentally switched back on and position a visible warning sign 1 Switch off mains fuse secure against being accidentally switched back on and fit a warnin...

Страница 40: ...1 The fan also switches off after the room lighting has been turned off ER 60 EVZ ER 100 EVZ Standard switching The fan starts up approximately 50 seconds after the room lighting is switched on The fan has an overrun time of 15 minutes after switching off Switching option The fan starts up approx 50 seconds after switching on the room lighting with switch S1 and S2 The fan has an overrun time of 1...

Страница 41: ...the relative humidity falls below the reference value Switching option 1 Permanent base load operation with pre defined overrun time The fan is running in base load operation Humidity control is active see Standard Switching Switch S1 is used to switch manually to full load operation After switching full load operation off with S1 the fan continues in full load operation for an overrun time of 15 ...

Страница 42: ......

Страница 43: ... active After switching off with S1 the fan continues in full load operation for an overrun time of 6 minutes If after this time the humidity as measured at the fan is higher than the switch off point the fan continues to run in full load operation until the humidity drops below the switch off point Only then does the fan switch off automatically is lower than the switch off point the fan immediat...

Страница 44: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 technik maico de 06 18_Es D06 18_UK_DSW ...

Страница 45: ...тяжные вентиляторы Канальные вентиляторы Реверсивные вентиляторы Комплектующие вентиляции Проектирование систем вентиляции Установка вытяжных вентиляторов Кухонные вытяжки Воздуховоды Воздухораспределительные устройства ...

Отзывы: