uk │ 6. Safety instructions 

 

16 

● With a free inlet, never 

operate the unit without a 
protective grille, for example, 
fit a protective grille SGR in 
front of the housing. 

● Ensure a sufficient fresh air 

supply intake. 

● Modifications and alterations 

to the unit are not permitted 
and release the manufacturer 
from any guarantee and 
liability. 

 

6.2 Safe and correct practices 
during operation 

Danger of injury from 
objects in the impeller.  
Do not insert any objects 
in the unit. 

Danger of injury from 
rotating impeller. Do not 
get too close to the unit,  
to avoid hair, clothing or 
jewellery being drawn into 
the unit. 

● This fan unit can be used by 

children aged 8 and above, 
and by people with reduced 
physical, sensory or mental 
capabilities or by persons with 
insufficient experience or 
knowledge provided they are 
supervised by a person 
responsible for their safety,  
 

or they have been instructed 
about the safe operation of 
the unit and can understand 
the resulting risks thereof. 
Children must not play with 
the unit. Cleaning and 
maintenance must not be 
carried out by children without 
supervision. 

 

 

7. Transportation, storage 

 

7.1 Transport 

NOTICE

 

Risk of damage to unit if 
means of transport are 
incorrectly attached. 

Do not place load on sensitive 
components, such as an impeller 
or terminal box. 

 

 

CAUTION 

Risk of cuts from metal 
housing plates with sharp 
edges. 

Wear protective gloves. 

 

 

Maico accepts no indemnification or 
warranty claims in the event of 
improper transport. 

 

7.2 Storage 

●  Only store fan horizontally in a suitable, 

dry room: ambient temperature  
- 10 to + 60 °C. 

●  Before installing, check that the motor 

bearing is working properly. 

●  Maico accepts no liability for corrosion 

damage caused by improper storage,  
e.g. storage in a damp room. 

 

Содержание EHD Series

Страница 1: ...fugal roof fans Tourelles centrifuges EHD 10 EHD 12 EHD 15 EHD 16 EHD 20 EHD 25 EHD 31 Montage und Betriebsanleitung Mounting and Operating instructions Instructions de montage et Mode d emploi www m...

Страница 2: ...Zus tzliche Informationen Mit dem Smartphone direkt zum Produkt Im Internet unter maico ventilatoren com EHD 10 EHD 31 1 Lieferumfang EHD Dachventilator mit quadratischem Dachsockel Zubeh rbeutel im K...

Страница 3: ...INFO Symbol f r wichtige Infor mationen und Tipps Aufz hlungssymbol f r Informa tionen zum jeweiligen Thema 1 Handlungsanweisung F hren Sie die angegebenen Anwei sungen der Reihe nach durch 3 Produkt...

Страница 4: ...t fest installierter elektrischen Zuleitung ist vorgeschrieben Mit Dacksockel 10 nur auf einem geeigneten Unterbau Ohne Dachsockel 10 direkt auf dem Entl ftungsrohr Zul ssig sind Einbaulagen bis zu ei...

Страница 5: ...hen und trittsicher sein Bei Arbeiten auf dem Dach sind ausreichende Sicher heitsvorkehrungen zum Schutz des Installations personals zu treffen Die auf dem Typenschild angegebene Schutzart ist nur ge...

Страница 6: ...r t hinein gezogen werden k nnen Dieses Ger t kann von Kindern ab 8 Jahren und dar ber sowie von Personen mit verringerten physischen sensorischen oder mentalen F higkeiten oder Mangel an Erfahrung un...

Страница 7: ...sockel nur auf einen passenden ebenen Unterbau schrauben F r die direkte Montage des EHD Ger tes auf die L ftungsleitung EHD Dachsockel abmontieren 3 Blechschrauben Zwischen Ger t und Dachsockel ge ei...

Страница 8: ...Ventilator befestigen 5 Bei freier Ansaugung ein Schutzgitter Type SGR als Ber hrungs und Ein saugschutz anbringen 6 Geeignetes Isolations und Schalld mm material anbringen 9 2 Elektrischer Anschluss...

Страница 9: ...hlsteller Stufenlos regeln lassen sich EHD Ger te mit einem zur Ger tetype passenden Drehzahl steller Katalog Internet Durch die Technik der Phasen anschnittsteuerung kann es zu Brummger uschen kommen...

Страница 10: ...Eventuell auch den Repara turschalter berpr fen Ventilator schaltet nicht ein Laufrad blockiert Reparatur nur durch Fachkraft zul ssig Laufrad berpr fen und ggf reinigen Thermischer berlastungs schutz...

Страница 11: ...chalten diese gegen Wie dereinschalten sichern und ein Warnschild sichtbar anbringen 1 Netzsicherung ausschalten sichern und Warnschild anbringen 2 Anschlusskomponenten vom Ventilator entfernen 3 Geh...

Страница 12: ...e product with a smartphone Online at maico ventilatoren com EHD 10 EHD 31 1 Scope of delivery EHD Roof fans with square roof socket Accessories bag in terminal box Cable grommet and traction relief w...

Страница 13: ...mportant information and tips Bullet point for information on the corresponding subject 1 Instructions Follow the instructions given in the order stated 3 Product information 3 1 Equipment overview 1...

Страница 14: ...th permanent electrical supply cable is compulsory With roof socket 10 only on suitable base Without roof socket 10 directly on the air extraction pipe Installation positions of up to an angle of maxi...

Страница 15: ...ty of the installla tion staff appropriate measures should be taken in case of works on the roof The degree of protection stated on the rating plate is only guaranteed if installation is undertaken co...

Страница 16: ...rience or knowledge provided they are supervised by a person responsible for their safety or they have been instructed about the safe operation of the unit and can understand the resulting risks there...

Страница 17: ...roof socket 3 tapping screws Use suitable insulation sound deadening and installation material between the unit and roof socket With a free inlet fit a protective grille type SGR in front of the fan...

Страница 18: ...rotective grille type SGR as protection against accidental contact and drawing in 6 Fit suitable insulation and sound deadening material 9 2 Electrical connection DANGER Danger to life from electric s...

Страница 19: ...rews 9 3 Operation with speed controller EHD units can be continuously adjusted with a speed controller suitable for the unit type catalogue internet The technology used in the phase angle controller...

Страница 20: ...necessary also check the service switch Fan does not switch on Impeller blocked Repairs may only be carried out by a trained specialist Check impeller and clean if necessary Motor s thermal overload p...

Страница 21: ...cure against being accidentally switched back on and position a visible warning sign 1 Switch off mains fuse secure and fit warning sign 2 Remove connection components from fan 3 Remove upper part of...

Страница 22: ...31 Informations suppl mentaires Acc s direct au produit via le smartphone Sur Internet sous maico ventilatoren com EHD 10 EHD 31 1 Volume de la fourniture Tourelle d extraction EHD avec socle de toit...

Страница 23: ...conseils importants Symbole d num ration signalant des informations relatives au sujet correspondant 1 Marche suivre Suivez les instructions fournies dans l ordre 3 Informations produit 3 1 Vue d ense...

Страница 24: ...on lectrique permanente est prescrit Avec socle de toit 10 seulement sur un support appropri Sans socle de toit 10 directement sur le tube d vacuation Des positions d installation jusqu une inclinaiso...

Страница 25: ...hapitre 1 Les installateurs ne doivent pas avoir le vertige et avoir le pied s r Lors des travaux sur le toit pr voir des pr ventions de s curit suffisantes pour la protection du personnel d installat...

Страница 26: ...e l appareil afin d viter que les cheveux les v tements ou les bijoux ne soient happ s Cet appareil peut tre utilis par des enfants de 8 ans et plus ainsi que par des personnes capacit s physiques sen...

Страница 27: ...uer des manchettes de fixation flexible type ELR Pour viter des fuites visser le socle de toit EHD sur un support plat appropri Pour monter l appareil EHD directement sur la gaine d air d monter au pr...

Страница 28: ...ttes ou des raccordements lastiques types EL ELA au ventilateur 5 En cas d aspiration libre monter une grille de protection type SGR contre les contacts et les risques d aspiration 6 Poser des mat ria...

Страница 29: ...ni par le client 9 Brancher d autres accessoires optionnels Chapitre 9 3 ou 9 4 ATTENTION Endommagement de l appa reil par pr sence d humidit lorsque le couvercle de bornier n a pas t pos en bonne et...

Страница 30: ...que de coupure par les tranchants des t les du bo tier Porter des gants de protection 11 limination des dysfonctionnements Lors de tout dysfonctionnement consulter un lectricien qualifi Les r paration...

Страница 31: ...ik GmbH Steinbeisstra e 20 78056 Villingen Schwenningen Allemagne T l 49 7720 694445 Fax 49 7720 694175 E Mail ersatzteilservice maico de 13 D montage Seul un lectricien sp cialis Chapitre 1 peut se c...

Страница 32: ...ansformateur 5 plots TRE EHD avec r gulateur de vitesse ST STU Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 694 447 technik maico de RLF 4_07...

Отзывы: