Maico ECA 120 Скачать руководство пользователя страница 16

Preface

16

Preface

Please read the instructions carefully before in-
stalling and using for the first time. Follow the in-
structions. Pass these instructions on to the
owner for safekeeping.

1 Scope of delivery

• Fan

• Installation and operating instructions

2 Specialist installer qualifications

Installation may only be carried out by 

trained

specialists

 who have the necessary knowledge

and experience in 

ventilation engineering

. The

unit must be connected in accordance with the
national technical approval.
Only a 

qualified electrician

 is permitted to work

on the electrics. You are deemed a qualified elec-
trician if you are familiar with the relevant stand-
ards and guidelines, can competently and safely
connect units to an electrical power supply in line
with the Wiring diagram and are able to recognise
and avoid risks and dangers associated with elec-
tricity on the basis of your technical training and
experience.

3 Intended use

The unit is used for extracting air from bathrooms,
toilets, storage rooms, showrooms, cellars, of-
fices, communal showers in clubhouses, fitness
centres, changing rooms and similar rooms.
Operation is only permitted with:

• a fixed installation within buildings

• installation on walls or ceilings

• an air supply via shaft or duct

• electrical flush-mounted connections
The operation of the 24 V model is only permitted
with approved safety isolating transformer TRE
50 (230 V/24 V). The time delay switches are to
be installed between switch (230 V) and input
side of the safety isolating transformer in accord-
ance with the wiring diagram.
This unit is only intended for domestic use and
similar purposes.

4 Safety instructions

4.1 General safety instructions

The unit must not be used in the following situ-
ations under any circumstances:

 DANGER Risk of combustion/fire from

flammable materials, liquids or gases in the
vicinity of the unit.

Do not place any flammable materials, liquids or
gases near the unit, which may ignite in the event
of heat or sparks and catch fire.

 DANGER Explosive gases and dust may

ignite and cause serious explosions or fire.

Never use fan unit in an explosive atmosphere
(risk of explosion).

 WARNING Risk from operating in single

air extraction systems in accordance with DIN
18017-3.

Fan does not satisfy the DIN 18017-3 standard.
Do not use fan in systems in accordance with
DIN 18017-3.

 WARNING Risk to health from chemicals

or aggressive gases/vapours.

Chemicals or aggressive gases/vapours may
harm health, especially if they are distributed
throughout the rooms by the unit.
Never use unit to distribute chemicals or aggress-
ive gases/vapours.

NOTICE Damage to unit due to grease and oil
vapours from range hoods.

Grease and oil vapours from range hoods may
contaminate the unit and air ducts and reduce ef-
ficiency.
Never use unit to convey these substances.

4.2 Safety instructions regarding in-
stallation, operation, cleaning and
maintenance

 DANGER Risks for children and people

with reduced physical, sensory or mental cap-
abilities or a lack of knowledge.

Unit may only be installed, commissioned,
cleaned and maintained by persons who can
safely recognise and avoid the risks associated
with this work.

 WARNING Risk of injury due to suction

from unit and rotating impeller.

Hair, clothing, jewellery etc. may be pulled into
the unit if you get too close to it.
During operation, always keep far enough away
to prevent this from happening.

Содержание ECA 120

Страница 1: ...allation and operating instructions Notice de montage et mode d emploi ECA 120 ECA 120 VZ ECA 120 F ECA 120 P ECA 120 24 V ECA 120 K ECA 120 KVZ ECA 120 KF ECA 120 KP Kleinraumventilatoren Small room...

Страница 2: ...Inhaltsverzeichnis Deutsch 3 English 14 Fran ais 25...

Страница 3: ...se mit Motor 5 Elektronikplatine 5 1 Grundplatine Standard P 24 V 5 2 VZ Platine 5 3 F Platine 6 Klemmleiste 7 Elektronikabdeckung VZ KVZ F KF 8 Motorschutzdeckel 9 Fl gelrad 10 ECA 120 K Thermo Bimet...

Страница 4: ...20 VZ ECA 120 KVZ 7 5 3 ECA 120 F ECA 120 KF 7 5 4 ECA 120 P ECA 120 KP 7 5 5 ECA 120 24 V 7 6 Technische Daten 7 6 1 Umgebungsbedingungen 7 6 2 Technische Datentabelle 7 7 Montagevorbereitungen 8 7 1...

Страница 5: ...Gebrauch und hnliche Zwecke vorgesehen 4 Sicherheitshinweise 4 1 Allgemeine Sicherheitshinweise Das Ger t darf in folgenden Situationen auf kei nen Fall eingesetzt werden GEFAHR Entz ndungs Brandgefah...

Страница 6: ...gt f r eine ausreichende Zuluftnachstr mung sorgen GEFAHR Gefahr durch Stromschlag bei Betrieb mit nicht komplett montiertem oder besch digtem Ventilator Vor dem Abnehmen des Elektronikabdeckung al le...

Страница 7: ...Nicht drehzahlsteuerbar Erforderliche Netzzuleitung 3 x 1 5 mm 5 4 ECA 120 P ECA 120 KP Kleinraumventilator zum Entl ften von R umen Ausf hrung mit Zugschnurschaltung ECA 120 P mit feststehendem Innen...

Страница 8: ...en Wickelfalzrohre durch Federhaken Vor Einbau in flexible Rohre die Federhaken ab brechen 2 Montagvorbereitung wie in Kapitel Wand 8 beschrieben vornehmen 8 Montage und Inbetriebnahme 8 1 Ventilator...

Страница 9: ...iste anschlie en je nach ECA 120 Variante 2 oder 3 adrig Schaltbilder 11 3 Bei Aufputzanschluss AP die Zugentlastung verwenden 4 Korrekten Sitz der Leitungst lle kontrollieren Diese muss gut abdichten...

Страница 10: ...ten Fl gelrad blockiert Beseitigung nur durch Fachkraft zu l ssig Innengitter Klappenrahmen entrie geln und abnehmen Fl gelrad berpr fen und ggf reinigen Ventilator schaltet nicht aus VZ oder F Ger t...

Страница 11: ...le k nnen unter www shop maico venti latoren com bestellt werden 14 Demontage Die Demontage ist nur durch Elektrofachkr fte zul ssig 1 Innengitter Klappenrahmen entriegeln und ab nehmen 2 Elektronikab...

Страница 12: ...16 Schaltbilder 12 ECA 120 VZ ECA 120 F ECA 120 P ECA 120 24 V ECA 120 K...

Страница 13: ...o Elektroapparate Fabrik GmbH Deutsche Original Betriebsanleitung Druckfehler Irrt mer und technische nderungen vorbehalten Die in diesem Dokument erw hnten Marken Handels marken und gesch tzte Warenz...

Страница 14: ...ic circuit board 5 1 Mother board Standard P 24 V 5 2 VZ circuit board 5 3 F circuit board 6 Terminal block 7 Electronics cover VZ KVZ F KF 8 Motor protection cover 9 Impeller 10 ECA 120 K Thermostati...

Страница 15: ...5 3 ECA 120 F ECA 120 KF 18 5 4 ECA 120 P ECA 120 KP 18 5 5 ECA 120 24 V 18 6 Technical data 18 6 1 Ambient conditions 18 6 2 Technical data table 18 7 Preparations for installation 18 7 1 Wall 18 7...

Страница 16: ...domestic use and similar purposes 4 Safety instructions 4 1 General safety instructions The unit must not be used in the following situ ations under any circumstances DANGER Risk of combustion fire f...

Страница 17: ...nd position a visible warning sign Only operate the fan when it is completely in stalled Do not commission a damaged unit DANGER Danger if the relevant regula tions for electrical installations are no...

Страница 18: ...speed controllable Required mains cable 3 x 1 5 mm 5 5 ECA 120 24 V Small room fans for extracting air from rooms Model with safety extra low voltage ECA 120 24 V with fixed internal grille Rated volt...

Страница 19: ...er 8 2 Housing installation NOTICE Damage to unit functional problems in the event of rubbing impeller Do not fit flange sleeve either twisted or crushed Make sure that the surface is flat 1 Insert ho...

Страница 20: ...st be well sealed 8 4 Final mounting 1 ECA 120 K Attach electronics cover 11 ECA 120 K Bimetal cover 12 Internal grille shutter frame 2 Carefully push the internal grille and or shutter frame onto the...

Страница 21: ...necessary Fan does not switch off VZ or F units Wait for overrun time approx 6 minutes Motor s thermal over load protection switches the fan off Motor too hot Wait until the motor has cooled down Coo...

Страница 22: ...ernal grille shutter frame 2 Remove the electronics cover remove the power cable 3 Remove fan To do this press both locking hooks out of their latched positions using a screwdriver and pull the fan ou...

Страница 23: ...16 Wiring diagrams 23 ECA 120 F ECA 120 P ECA 120 24 V ECA 120 K ECA 120 KVZ...

Страница 24: ...co Elektroapparate Fabrik GmbH Transla tion of the original operating instructions Mis prints errors and technical changes are reserved The brands brand names and protected trade marks that are referr...

Страница 25: ...avec moteur 5 Platine lectronique 5 1 Platine de base standard P 24 V 5 2 Platine VZ 5 3 Platine F 6 R glette de bornier 7 Cache lectronique VZ KVZ F KF 8 Couvercle de protection moteur 9 H lice 10 EC...

Страница 26: ...29 5 4 ECA 120 P ECA 120 KP 30 5 5 ECA 120 24 V 30 6 Caract ristiques techniques 30 6 1 Conditions ambiantes 30 6 2 Tableau de donn es techniques 30 7 Pr paratifs de montage 30 7 1 Mur 30 7 2 Plafond...

Страница 27: ...TRE 50 230 V 24 V Monter les in terrupteurs temporisateurs entre l interrupteur 230 V et l entr e du transformateur de s curit selon le sch ma de branchement Cet appareil est exclusivement r serv l us...

Страница 28: ...RTISSEMENT Risque de blessure et pour la sant en cas de modifications ou de transformations ou encore en cas d utilisation de composants non autoris s Le fonctionnement n est autoris qu avec des compo...

Страница 29: ...s risque d touffement 5 Informations produit 5 1 ECA 120 ECA 120 K A rateur pour petite pi ce destin l vacua tion d air des locaux Version standard ECA 120 avec grille int rieure fixe ECA 120 K avec c...

Страница 30: ...1000 4000 V En cas de fonctionnement avec tubes fluorescents des mesures d antiparasitage sup pl mentaires sont n cessaires composants L C ou RC diodes de protection varistors ces valeurs risquant d t...

Страница 31: ...ns les r gles de l art de l eau risque de s introduire dans le bo tier du ventilateur Le type de protection n est pas garanti Percer le manchon de c ble de mani re ce qu il enveloppe troitement le c b...

Страница 32: ...iv avec un inter rupteur p ex interrupteur d clairage selon la variante de l appareil avec temporisation de d marrage pour les appareils VZ et F la mise en marche l arr t se fait automatiquement ou pa...

Страница 33: ...ircuit Moteur trop chaud Attendre le refroidisse ment du moteur Le temps de refroidisse ment peut atteindre jusqu 10 minutes L appareil se remet au tomatiquement en marche d s qu il a re froidi Sur le...

Страница 34: ...ets d arr t hors de l encliquetage et d gager le ventilateur sans brusquer 15 limination dans le respect de l environnement L appareil ainsi que son emballage contiennent des mat riaux recyclables qui...

Страница 35: ...16 Sch mas de branchement 35 ECA 120 P ECA 120 24 V ECA 120 K ECA 120 KVZ ECA 120 KF ECA 120 KP...