INSTALLATION INSTRUCTIONS

ECA 120 VZ

Version: 2018-01-25 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 5

1

ECA fan

2

WH wall sleeve

3

AP outside shutter

4

Masonry

5

Plaster

6

Cable entry

Ceiling installation with roof cowl

Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a

ceiling in ventilation systems with a roof cowl:

The minimum distance from the wall must be observed (see wall mounting as well).

Install the wall sleeve or duct.

Surface- or recessed-mounted connecting cable guide.

ECA 100 ipro and ECA piano only available as recessed-mounted fans.

Drain off any condensation present in the duct using a siphon. Fit a T-piece with siphon in the duct (odour seal) for this

purpose.

Proper duct insulation reduces the build-up of condensation considerably.

Use a roof cowl with the condensation drain pointing outwards, see recommended accessories.

1

ECA fan

2

Sleeve WH ...

3

Duct, DN 100, DN 125 or DN 150

4

Masonry

5

Plaster

6

Insulation

7

DF/DP roof cowl (DN 125/160, possibly adapted by customer)