ECA 100 & ECA 120 Fans

These fans are designed for the ventilation of
bathrooms, toilets, storage rooms, offices, etc.

ECA fans

 are equipped with a fixed internal grille.

ECA-K

 fans have an electrically operated internal

shutter.

MAICO is not liable for any damage caused by the
improper use of these fans.

Safety instructions:

 

For your own safety,

please read these instructions before starting
work. Keep these instructions somewhere safe
for future reference.

Electrical connections and repairs may only be
carried out by a qualified electrician.

Take note of all relevant guidelines during electrical
equipment installation, particularly DIN VDE 0100
and all its corresponding parts.

Entanglement danger: The fan should only be
operated when the cover [8] is in position.

 

Do

not get too close to the fan

 with hair or with loose

clothing, to avoid the danger of getting caught up
in the unit.

The unit may only be operated:

–  when surface mounted on wall, ceiling, shaft or

ducting, as described below

–  with sufficient spacing to the wall and ceiling, see

fig. 1A

–  when installed in a window with window installation

kit FE 100 (only with ECA 100 units).

The unit may not be operated:

in proximity to flammable materials, fluids or gases.

When operated with air ventilated fireplaces, you
must allow for sufficient supply airflow. The
maximum permitted pressure difference between
living units is 4 Pa.

The highest permitted airstream temperature is
40 °C.

Don’t insert any objects through the protective
grille. Danger of injury from a running fan.

Before removing the cover [8], disconnect the unit
completely from the power supply. Switch off the
breaker switch in the fuse box.

Components/Accessories

Whenever ordering replacement parts always quote
the number 0185.0984.0000, the manufacturing
date 

“X” 

(stamp near the connector) and the

corresponding position number.
 1

Housing with motor

 2

ECA  board

 2.1 Base  board
 2.2 VZ 6 board
 2.3 VZ 24 C board
 2.4 VZI 10 board
 2.5 F board
 3

Board safety cover

 4

Motor safety cover with 

rating plate

 5

Fan impeller with circlip

 6

Bi-metal support (with ECA-K)

 7

Bi-metal support cover (with ECA-K)

 8

Cover: Fixed internal grille (ECA)
Electrically operated internal shutter (ECA-K)

Function

The fan is switched on with a switch to be supplied
by the installer. The exceptions to this are P fans with
pull-cord switch, which are switched on or off by
means of the pull-cord, and F fans, which don’t need
a switch.
Depending on the model, the fan starts up directly
with a start delay or when the brightness in the room
gets down to the corresponding level. The fan is
either switched off manually or after a corresponding
overrun time, once the room has been vacated.

Electrical connection

Refer to last page for a wiring diagram.

The fan may only be connected to a fixed
electrical installation (max 1.5 mm

2

). This must be

equipped with a power separation device with at
least 3 mm contact opening at each pin.

The power supply must conform to the voltage
specified on the rating plate [4].

Use only flexible cabling H05VV-F for installations
with FE 100 window installation kit.

Screening and non-used cable cores should be
cut back and insulated to avoid the possibility of
short circuits or the malfunctioning of the internal
shutter in the case of K fans.

VZ, VZC, I and F fans: Noise resistance in
accordance with DIN EN 55014-2 depending on
impulse shape and power content 1000 to 4000 V.
These values can be exceeded when used with
fluorescent tubes. In this case, additional
suppression measures are necessary (L, C or RC
elements, protective diodes, varistors).

Subject to change !

Содержание ECA 100 K SERIES

Страница 1: ...maico de ECA 100 ECA 100 K ECA 120 ECA 120 K Montage Betriebsanleitung Mounting Operating instructions Instructions de montage Mode d emploi Kleinraum Ventilator Small Room Fan A rateur pour petits lo...

Страница 2: ...8 1E 1B AP UP 1A AP 1C UP 1D...

Страница 3: ...4 5 2 3...

Страница 4: ...icherung im Sicherungskasten ausschalten Komponenten Ersatzteile Hinweis zu Ersatzteil Bestellungen Geben Sie generell die Druck Nr 0185 0984 0000 das Produktionsdatum X Stempel im Anschlussraum und d...

Страница 5: ...altverz gerung ca 50 Sekunden und Nachlaufzeit ca 6 Minuten fest eingestellt VZC Ausf hrung mit einstellbarem Verz gerungszeitschalter Mit VZ 24 C Platine 2 3 und Schutzabdeckung nicht drehzahlsteuerb...

Страница 6: ...ng replacement parts always quote the number 0185 0984 0000 the manufacturing date X stamp near the connector and the corresponding position number 1 Housing with motor 2 ECA board 2 1 Base board 2 2...

Страница 7: ...h VZ 6 board 2 2 and safety cover single speed only Start delay and overrun time fixed at approx 50 seconds and approx 6 minutes respectively VZC model with settable time delay switch With VZ 24 C boa...

Страница 8: ...l appareil tous les p les du secteur Pour ce faire arr ter le disjoncteur secteur dans la bo te fusible Composants pi ces de rechange Remarque relative aux commandes de pi ces de rechange Indiquez to...

Страница 9: ...ercle de protection vitesse de rotation non r glable Temporisation de d marrage env 50 secondes et fonctionnement par inertie d environ 6 minutes r gl s de fa on fixe Version VZC avec temporisateur r...

Страница 10: ...A 100 24 V ECA 120 24 V ECA 100 KF ECA 120 KF ECA 100 KP ECA 120 KP ECA 100 P 24 V ECA 100 KP 24 V ECA 120 P 24 V ECA 120 KP 24 V N L M 1 1 L N N L M 1 1 L N TRE 50 230 24V M 1 1 N L L N t1 t2 VZ F N...

Отзывы: