2. Product information 

 EN 

 

13 

2. Product information 

 

2.1 Unit overview, Fig. A, B and C 

Housing with motor 

Impeller 

Cable grommet 

Electronics cover 

Internal grille or internal shutter 

5.1  Fixed internal grille 
5.2  Electrically operated internal shutter 
5.3  Bimetal 

Cover 

Designer cover 

Electronic circuit boards 

8.1  Standard electronics 
8.2  Sensor electronics  

(only for models F, H and B) 

8.3  VZC electronics 

Sensors 

9.1 

Motion sensor “B”

 

9.2  Light 

sensor “F”

 

9.3 

Humidity sensor “H”

 

10  Start delay/overrun time for LEDs 
11  Start delay setting button 
12  Overrun time setting button 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2 Product description 

  Small room fan for extracting air from 

rooms. 

 

ECA 100 ipro

 with fixed internal grille. 

 

ECA 100 ipro K 

with electrically operated 

internal shutter. 

  Two performance levels as standard. 

 

Models 
Standard: 

Can be operated at two levels 

with an optional double switch. 

VZC 

and 

KVZC: 

Model with start delay  

and overrun time. 

F

 and

 KF: 

Model with light sensor, start 

delay and overrun time. Switch-on intensity 
(at fan) min. 30 lux. Switch-off intensity  
(at fan) max. 1.7 lux. 

and

 KH: 

Model with humidity control 

(fully automatic), start delay and overrun 
time. 

and

 KB: 

Model with motion detector and 

overrun time. Without start delay. Monito-
ring range of motion detector horizontal 
100°/vertical 82°. 

Unit model

 

Start delay 

[sec.]

 

Overrun time 

[min.]

 

Mains cable 

[mm²]

 

4 operating 

programmes

 

Speed 

controllable

 

ECA 100 ipro 

 

 

5 x 1,5 

 

 

ECA 100 ipro VZC 

0/

50

/90/120 

0/

8

/17/25 

5 x 1,5 

 

 

ECA 100 ipro F 

0

/50/90/120 

0/

8

/17/25 

3 x 1,5 

 

 

ECA 100 ipro H 

0/

50

/90/120

*

 

8

/17/25** 

3 x 1,5 

 

 

ECA 100 ipro B 

 

0/

8

/17/25 

3 x 1,5 

 

 

ECA 100 ipro K 

 

 

5 x 1,5 

 

 

ECA 100 ipro KVZC 

0/

50

/90/120 

0/

8

/17/25 

5 x 1,5 

 

 

ECA 100 ipro KF 

0

/50/90/120 

0/

8

/17/25 

3 x 1,5 

 

 

ECA 100 ipro KH 

0/

50

/90/120

*

 

8

/17/25

**

 

3 x 1,5 

 

 

ECA 100 ipro KB 

 

0/

8

/17/25 

3 x 1,5 

 

 

 

Bold

  Condition as supplied 

*

 

Start delay available when using an optional switch 

  

Standard equipment  

 

(e.g. light switch). 

  

4 operating programs available 

**

  0 min overrun time available when using an optional 

       

with optional light switch 

 

switch (e.g. light switch). 

Содержание ECA 100 ipro VZC

Страница 1: ...ons Small room fans Instructions de montage et Mode d emploi A rateurs pour petites pi ces ECA 100 ipro ECA 100 ipro VZC ECA 100 ipro F ECA 100 ipro H ECA 100 ipro B ECA 100 ipro K ECA 100 ipro KVZC E...

Страница 2: ...tilatoren com Mounting an Operating instructions Page 12 Wiring diagrams Page 33 Scope of delivery Small room fan ECA 100 ipro Electronics cover Sensor only for models F H and B Foam strip Installatio...

Страница 3: ...A B C...

Страница 4: ...Benutzung des Ventilators auf merksam durch Folgen Sie den Anweisungen Bewahren Sie diese Anleitung f r einen sp teren Gebrauch gut auf 1 1 Installationspersonal Montage nur durch Fachkr fte zul ssig...

Страница 5: ...it Lichtsensor Einschaltverz gerung und Nachlaufzeit Einschalthelligkeit am Ger t min 30 Lux Ausschalthelligkeit am Ger t max 1 7 Lux H und KH Ausf hrung mit Feuchte steuerung vollautomatisch Einschal...

Страница 6: ...hste Priorit t und steuert das Ger t wie zuvor beschrieben 2 3 Bestimmungsgem e Verwendung Dieses Ger t ist ausschlie lich f r den Hausgebrauch und hnliche Zwecke vorgesehen Das Ger t dient zur Entl f...

Страница 7: ...st nden im Fl gel rad Keine Gegenst nde in das Ger t hineinstecken Verletzungsgefahr durch sich drehendes Fl gelrad Nicht zu nahe an das Ger t gehen damit Haare Kleidung oder Schmuck nicht in das Ger...

Страница 8: ...tageort verlegen Abstandsma e siehe oben Dabei die Netzleitung mindestens 110 mm aus der Wand herausf hren 6 2 Decke ACHTUNG Kurzschlussgefahr und Ger tebesch digung durch Kondenswasserbildung im Vent...

Страница 9: ...h besser biegen und Elektronikabdeckung 4 korrekt aufsetzen Leitungst lle 3 fachgerecht anbringen ggf bauseitig abdichten 5 Leitungst lle 3 in Geh use einsetzen Netzleitung so in den Anschlussraum f h...

Страница 10: ...pitel 13 angeschlossenem Licht schalter ist eines der 4 nachfolgenden Betriebsprogramme einstellbar Wird dieses eingeschaltet hat es Vorrang vor der Feuchteautomatik Komfortprogramm Auslieferungszusta...

Страница 11: ...n Ausklappseite Abbildung B 7 4 Inbetriebnahme 1 Netzsicherung einschalten 2 Funktionstest durchf hren 7 5 Einschaltverz gerung und Nachlaufzeit Beim ersten Dr cken der Einstell taste wird der aktuell...

Страница 12: ...eine Netzspannung Pr fen ob die Netzsicherung aus gefallen ist Diese ggf einschalten Ventilator schaltet nicht ein Laufrad blockiert Nur durch Fachkraft zul ssig Abdeckung 6 abnehmen Innengitter 5 1 o...

Страница 13: ...5 3 ist nach Ausschalten des Ventilators sehr hei Die Abk hlzeit kann bis zu 10 Minuten betragen 1 Abdeckungen entriegeln Pfeil und abnehmen 2 Elektronikabdeckung 4 entfernen 3 Rastnasen 3 Netzleitun...

Страница 14: ...low the instructions Keep these instructions safe for use later on 1 1 Installation staff Installation is only permitted when carried out by trained specialists Electrical connections and repairs only...

Страница 15: ...overrun time F and KF Model with light sensor start delay and overrun time Switch on intensity at fan min 30 lux Switch off intensity at fan max 1 7 lux H and KH Model with humidity control fully auto...

Страница 16: ...t as described above 2 3 Intended use This device is only intended for domestic use and similar purposes Fan for or extracting air from bathrooms toilet rooms storage rooms showrooms offices fitness s...

Страница 17: ...on Danger of injury caused by objects in the impeller Do not insert any objects in the fan unit Danger of injury from rotating impeller Do not get too close to the fan unit to avoid hair clothing or j...

Страница 18: ...power cable recessed up to place of installation see above for spacing Guide the power cable at least 110 mm from the wall 6 2 Ceiling NOTICE Danger of short circuits and damage to unit if conden sati...

Страница 19: ...ronics cover 4 can be positioned correctly Fit cable grommet 3 correctly seal on both sides if required 5 Insert cable grommet into housing Guide power cable into connection area such that the cable g...

Страница 20: ...J4 and J5 and the light switch connected in accordance with chapter 13 If this is switched on it takes priority over the automatic humidity process Comfort program supplied in this mode night program...

Страница 21: ...ter 7 5 7 Fit designer cover 7 fold out page Fig B 7 4 Start up 1 Switch the mains fuse on 2 Carry out a function test 7 5 Start delay and overrun time When the setting button is pressed for the first...

Страница 22: ...ion Fault Cause Measure Fan does not switch on Start delay max 120 seconds Wait for the start delay and reduce if necessary Chap 7 5 Fan does not switch on No mains voltage Check whether the mains fus...

Страница 23: ...an DANGER Danger to life from electric shock Switch off mains fuse before removing CAUTION Danger of burning due to contact with bimetal K units Bimetal 5 3 is very hot after fan is switched off Do no...

Страница 24: ...e manuel d utilisation et de montage avant la premi re utilisation du ventilateur Suivez les instructions Conservez soigneusement ce manuel pour pouvoir le consulter ult rieurement 1 1 Installateurs M...

Страница 25: ...ec capteur de lumi re temporisation de d marrage et dur e de fonctionnement par temporisation Lumino sit de mise en marche d arr t au niveau de l appareil min 30 lux max 1 7 lux H et KH version avec c...

Страница 26: ...du temps de fonctionnement par inertie r siduel Ensuite la priorit revient au contr leur d humidit qui commande l ap pareil comme d crit pr c demment 2 3 Utilisation conforme Cet appareil est con u u...

Страница 27: ...ns une ouverture de contact de 3 mm sur chaque p le est n cessaire Utiliser exclusivement l appareil la tension et la fr quence indiqu es sur la plaque signal tique N effectuer aucune modifica tion su...

Страница 28: ...ts minimaux prescrits entre le mur et le plafond selon l illustration 1 Assurer un support plan autour de l appareil 2 Pratiquer une perc e dans la paroi ou percer des avant trous Diam tre minimal 105...

Страница 29: ...aine murale TOP dessus 2 Aligner le bo tier horizontalement et signaler les deux trous pour cheville fl che 3 Retirer le bo tier 1 percer des trous pour chevilles M6 de 6 mm et enfoncer les chevilles...

Страница 30: ...te 3 Raccorder lectriquement le c ble secteur sur le crampon lastique 13 selon l illustration du sch ma de raccordement 14 Voir aussi les illustrations de commutation du chapitre 13 Les appareils ECA...

Страница 31: ...iveau de puissance 2 lors du fonc tionnement et du fonctionnement par temporisation J4 pont J5 ouvert 2 Mettre en place le cache de l lectronique ATTENTION Risque de court circuit et d endommagement d...

Страница 32: ...la dur e de temporisation de d marrage d sir e s allume Attendre jusqu ce que le voyant LED clignote deux fois avant de s teindre La valeur est alors enregistr e 3 R gler la dur e de fonctionnement p...

Страница 33: ...se met pas en marche La turbine est bloqu e Intervention devant tre uniquement r alis e par un sp cialiste Retirer le cache 6 D bloquer la grille int rieure 5 1 ou la fermeture int rieure 5 2 via les...

Страница 34: ...DANGER Risque d lectrocution Couper le fusible secteur avant le d montage PRUDENCE Danger de br lure en cas de contact avec le bilame appareils de la s rie K Le bilame 5 3 est tr s chaud apr s mise h...

Страница 35: ...lder ECA 100 ipro ECA 100 ipro K Nenndrehzahl hohe Stufe Nominal speed high level R gime nominal de niveau lev ECA 100 ipro ECA 100 ipro K Nenndrehzahl niedrige Stufe Nominal speed low level R gime no...

Страница 36: ...faible ECA 100 ipro mit with avec ST1 STU1 ECA 100 ipro K mit with avec ST1 STU1 Drehzahl mit ST1 STU1 einstellbar Rotating speed adjustable with ST 1 STU 1 Vitesse r glable avec ST1 STU1 ST1 Drehzah...

Страница 37: ...13 Schaltbilder Wiring diagrams Sch mas de branchement FR EN DE 35 ECA 100 ipro VZC ECA 100 ipro KVZC ECA 100 ipro H ECA 100 ipro KH ECA 100 ipro F ECA 100 ipro KF ECA 100 ipro B ECA 100 ipro KB...

Страница 38: ...de gb Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 694 447 technik maico de 0185 1133 0002_RLF 4_11 14_DSW...

Отзывы: