EN
23
6.3 Supply air intake within
the living area
● The domestic air supply must
be set up so that virtually no
air can flow into the living
areas from the kitchen,
bathroom and WC.
● There must be sufficient
supply air within the living unit.
Non-lockable overflow outlets
must be used for this purpose.
7. Installation preparations
Wall
The prescribed minimum distances
between the wall and the ceiling
shown in the figure must be observed.
Make sure the housing has a level base.
1.
Fit wall breakthrough or drill core hole.
2.
Minimum diameter, 105 mm.
Recommendation: Fit WH 100 wall
sleeve.
Use ZM 11 mounting plate for
rectangular wall breakthroughs.
Always note the relevant specifica-
tions for electrical installations and
when installing equipment. In Germany
particular attention must be paid to
the DIN VDE 0100 and the
corresponding parts.
Lay power cable (recessed) up to place of
3.
installation, see above for spacing.
Feed
the power cable at least 100 mm out
from the wall.
Ceiling
NOTICE
Danger of short-circuits and
damage to unit if
condensation builds up in the
fan housing.
Thermally insulate ventilation
ducts in a professional manner.
Allow for a condensation drain or
condensed water collector in the
riser.
Carry out the ceiling installation as described
in the "Wall" mounting section.
Duct
Debur edges on the inside of the duct.
1.
Carry out the ceiling installation as
2.
described in the "Wall" mounting section.
Fan
Unpack ECA and remove cover [6].
1.
Release the locking hook (
arrow in
the Fig. above) using a screwdriver.
i
i
i
i