2. Product information
│
EN
13
2. Product information
2.1 Unit overview, Fig. A, B and C
1
Housing with motor
2
Impeller
3
Cable grommet
4
Electronics cover
5
Internal grille or internal shutter
5.1 Fixed internal grille
5.2 Electrically operated internal shutter
5.3 Bimetal
6
Cover
7
Designer cover
8
Electronic circuit boards
8.1 Standard electronics
8.2 Sensor electronics
(only for models F, H and B)
8.3 VZC electronics
9
Sensors
9.1
Motion sensor “B”
9.2 Light
sensor “F”
9.3
Humidity sensor “H”
10 Start delay/overrun time for LEDs
11 Start delay setting button
12 Overrun time setting button
2.2 Product description
●
Small room fan for extracting air from
rooms.
●
ECA 100 ipro
with fixed internal grille.
●
ECA 100 ipro K
with electrically operated
internal shutter.
●
Two performance levels as standard.
●
Models
Standard:
Can be operated at two levels
with an optional double switch.
VZC
and
KVZC:
Model with start delay
and overrun time.
F
and
KF:
Model with light sensor, start
delay and overrun time. Switch-on intensity
(at fan) min. 30 lux. Switch-off intensity
(at fan) max. 1.7 lux.
H
and
KH:
Model with humidity control
(fully automatic), start delay and overrun
time.
B
and
KB:
Model with motion detector and
overrun time. Without start delay. Monito-
ring range of motion detector horizontal
100°/vertical 82°.
Unit model
Start delay
[sec.]
Overrun time
[min.]
Mains cable
[mm²]
4 operating
programmes
Speed
controllable
ECA 100 ipro
5 x 1,5
●
ECA 100 ipro VZC
0/
50
/90/120
0/
8
/17/25
5 x 1,5
●
ECA 100 ipro F
0
/50/90/120
0/
8
/17/25
3 x 1,5
●
ECA 100 ipro H
0/
50
/90/120
*
8
/17/25**
3 x 1,5
ECA 100 ipro B
0/
8
/17/25
3 x 1,5
●
ECA 100 ipro K
5 x 1,5
●
ECA 100 ipro KVZC
0/
50
/90/120
0/
8
/17/25
5 x 1,5
●
ECA 100 ipro KF
0
/50/90/120
0/
8
/17/25
3 x 1,5
●
ECA 100 ipro KH
0/
50
/90/120
*
8
/17/25
**
3 x 1,5
ECA 100 ipro KB
0/
8
/17/25
3 x 1,5
●
Bold
Condition as supplied
*
Start delay available when using an optional switch
●
Standard equipment
(e.g. light switch).
4 operating programs available
**
0 min overrun time available when using an optional
with optional light switch
switch (e.g. light switch).
Содержание ECA 100 ipro KF
Страница 6: ...A B C...