│ General notes, Product information
10
2. General notes
Read these mounting instructions
carefully before using the ALD for
the first time. Follow the
instructions. Keep these
instructions safe for use later on.
2.1 Installation staff
Mounting is only permitted when carried out
by trained specialists.
Installation staff are trained in electrical
engineering and are aware of the risks and
consequences of an electric shock.
2.2 Symbols used
CAUTION
Possibly dangerous situation
which could result in minor to
moderate injuries.
NOTICE
Possible situation which could
cause damage to the product or
its surroundings.
INFO symbol indicating
important information and tips.
●
Bullet point for information on the
respective subject.
1.
Instructions. Follow the
instructions given in the order
stated.
3. Product information
3.1 Equipment overview, Fig. A
ALD 10 und ALD 10 T
1
Cover for external grille
2
Fly screen FG 100
3
Connection socket, external
4
Wall sleeve, 2-piece:
5
Sealing strips for sockets [6] or [9]
ALD 10
6
Frame, with slider/connection socket
7
Filter holder (2x), air filter (filter class G2)
8
Internal cover
ALD 10 T
9
Connection socket, internal
10 Spacing ring
11 Air filter, round (filter class G2)
12 Cover
3.2 Product description
ALD 10
Outside wall air opening for nominal size
100 mm. With external grille, wall sleeve and
square internal cover. Supply air element for
draught-free, decentralised domestic
ventilation with continuous regulation of the
air flow. Air volume can be adjusted
continuously using slider (iris closure):
● Slider to the left = CLOSED
● Slider to the right = OPEN
ALD 10 T
Airstream-operated outside wall air opening
(thermal version) for nominal size 100 mm.
With external grille, wall sleeve and thermo-
valve. For draught-free, decentralised
domestic ventilation with an integrated
thermostat. Supply air element opens or
closes automatically. Controls in the
temperature range
– 5 °C (closed) to + 10 °C
(open). Air volume can be adjusted by turning
the cover of the thermovalve. No electrical
connection required.
Option: Storm protection ALDS 10
(not included in the scope of delivery, for acces-
sories
current catalogue or the Internet):
A storm protection regulates the air flow during
strong or gusty winds and fully closes the air
channel during a storm. The occurrence of
draughts is prevented. For free-standing
buildings, installation is recommended on the
weather-exposed side from the 3rd floor up.