Maico ALD 10 T Скачать руководство пользователя страница 15

Disposal, Dimensions, Characteristic curves 

 UK 

 

15 

10. Disposal 

 

Do not dispose of in domestic 

waste. 

The ALD outside wall air 

opening contains in part material that 

can be recycled and in part 

substances that must not be 

disposed of with domestic waste. 

Dispose of the following components in 

compliance with the regulations valid in your 

country: 

● Packaging materials 

● Air filters 

● Once its service life is over, the complete 

outside wall air opening 
 

11. Dimensions 

 

ALD 10 

 

 

ALD 10 T 

 

 

12. Characteristic curves 

ALD 10 

 

 

= Slider position 

 

ALD 10 T 

 

 

= Gap opening [in mm] 

 
 
 
 
 
 

Содержание ALD 10 T

Страница 1: ...Montageanleitung Au enwand Luftdurchlass Mounting instructions Outside wall air opening ALD 10 ALD 10 T www m aico ventilatoren c om DE UK...

Страница 2: ...ang ALD 10 Innenteil Anschlussstutzen G2 Luftfilter 2x Filterhalter und Abdeckung Dichtungsstreifen Wandh lse 2 teilig f r Wandst rken bis 500 mm Au enteil Schutzgitter SG 100 inkl An schlussstutzen F...

Страница 3: ...lussstutzen 7 Filterhalter 2x Luftfilter Filterklasse G2 8 Innenabdeckung ALD 10 T 9 Anschlussstutzen innen 10 Distanzring 11 Luftfilter rund Filterklasse G2 12 Abdeckung 3 2 Produktbeschreibung ALD 1...

Страница 4: ...ter ALD10 28 m h ALD10 T 24 m h Wandst rke bis 500 mm Kernlochdurchmesser 115 mm Max Umgebungs temperatur 60 C Weitere technische Daten Abmessungen und Kennlinien Kapitel 11 und 12 Internet maico vent...

Страница 5: ...der Ver packung nehmen 2 Montageposition festlegen Mindestabstand von 110 mm von der Kernbohrungsmitte zur Wand und Decke nicht unterschreiten 6 3 Montage Wandh lse ACHTUNG Kondenswasser in Richtung...

Страница 6: ...lse schieben und den Rahmen an der Innenwand befestigen Geeignetes Befestigungsmaterial ist bauseitig bereit zustellen 4 Sicherstellen dass die Luftfiltereinheit 7 innerer Filterhalter Luftfilter und...

Страница 7: ...h Bei Temperaturen unter 10 C ver ndert sich der Spalt um 1 mm pro 1 K Minimalabstand 4 mm 8 Reinigung Filterwechsel F r Artikelnummern der Luftfilter Kapitel 9 Luftfilter T tigkeit G2 Luftfilter Stau...

Страница 8: ...hwenningen Deutschland Tel 49 7720 694 445 Fax 49 7720 694 175 E Mail ersatzteilservice maico de 10 Entsorgung Nicht in den Restm ll Der ALD Au enwand Luftdurchlass enth lt teils wiederverwertbare Sto...

Страница 9: ...for wall thicknesses up to 500 mm Outer part Protective grille SG 100 incl connection socket fly screen FG 100 Mounting instructions ALD 10 T Internal part Thermovalve with connection socket spacing...

Страница 10: ...Connection socket internal 10 Spacing ring 11 Air filter round filter class G2 12 Cover 3 2 Product description ALD 10 Outside wall air opening for nominal size 100 mm With external grille wall sleeve...

Страница 11: ...ial pressure and G2 air filter ALD10 28 m h ALD10 T 24 m h Wall thickness up to 500 mm Core hole diameter 115 mm Max ambient temperature 60 C Further technical data Dimensions and characteristic curve...

Страница 12: ...packaging 2 Decide on the installation position Ensure a minimum distance of 110 mm between the core hole centre and wall and ceiling 6 3 Mounting wall sleeve NOTICE Condensate will run towards the in...

Страница 13: ...pplied by the customer 4 Ensure that the air filter unit 7 inner filter holder air filter and external filter holder is correctly clipped onto the 4 corner points of the internal cover 8 5 Press entir...

Страница 14: ...y filter 8 1 Quarterly Check Change the air filter 7 or 11 quarterly as follows 1 Take off the internal cover 8 cover 12 2 ALD 10 Take the filter holder and the air filter out of the connection socket...

Страница 15: ...ed and in part substances that must not be disposed of with domestic waste Dispose of the following components in compliance with the regulations valid in your country Packaging materials Air filters...

Страница 16: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 technik maico de 03 16_Es 0185 0235 0002_RLF 4_03 16_DSW...

Отзывы: