8 Replacing PTC heat register

8

6. Insert the PTC heat register module into the

two slots in the EPP housing and secure it
with the two plastic locking pins (arrows)
provided.

7. Make a 90° elbow in the connecting cable and

thread the cable from pos. 

 to pos. 

. Ob-

serve arrows in EPP housing.

8. Make a 90° elbow in the connecting cable and

thread the cable from pos. 

 into the elec-

tronics compartment. Observe arrows in EPP
housing.

9. Connect the connection cables to the spring

terminal 

X5

 of the main circuit board → 

Wiring

diagram [

}

 14]

.

10.Insert both EPP sealing plugs into the EPP

housing.

11.Install the cover, electronics compartment and

front cover.

12.Attach housing cover.

13.Perform function test via the switching test

function

. Using the commissioning soft-

ware, set the Supply air heat register para-
meter to 

on

 in the main menu Settings/Switch-

ing test. After a short time the supply air fan
starts. When functioning correctly, heated air
flows out of the supply air opening. Set Supply
air heat register parameter to 

off

.

8 Replacing PTC heat register

1.

Powerbox H:

 Remove WS 75 APA/UPA/

UPGA cover. 

Powerbox S:

 Remove any

cover that may be present.

2. Remove the cover of electronics compartment

(2 screws).

3. Remove the two plastic locking pins on the

PTC heat register module and pull the module
out of the EPP housing.

 CAUTION Risk of burning on hot PTC

heat register or hot housing parts.

Only touch the heat register or housing parts
when they have cooled down.

4. Disconnect the wiring of the PTC heat register

and pull the connecting cable out of the cable
duct.

5. Install new PTC heat register as described in

the previous chapter.

 Only use genuine components.

9 Environmentally responsible
disposal

 Old devices and electronic components may

only be dismantled by specialists with elec-
trical training. 

Proper disposal avoids detri-

mental impact on people and the environment
and allows valuable raw materials to be reused
with the least amount of environmental impact.

Содержание 0093.1586

Страница 1: ...tallationsanleitung Installation instructions Notice d installation WS 75 PTC Nachheizregister WS 75 PTC supplementary heat register Registre de r chauffage PTC WS 75 WS 75 NH www maico ventilatoren c...

Страница 2: ...herungsstifte und diese Installati onsanleitung 3 Bestimmungsgem e Verwen dung Elektrisches PTC Nachheizregister f r WS 75 Po werbox S und H L ftungsger te mit W rmer ck gewinnung 4 Sicherheitshinweis...

Страница 3: ...EPP Verschlussstopfen 2 Abdeckung Elektronikfach entfernen 2 Befes tigungsschrauben 3 Die beiden oberen EPP Verschlussstopfen herausnehmen Anschlusskabel in 3 Schritten bis in das Elektronikfach f hr...

Страница 4: ...er Funktion str mt erw rmte Luft aus der Zuluft ffnung Parameter Zuluft heizregister auf aus stellen 8 PTC Heizregister austauschen 1 Powerbox H Abdeckung WS 75 APA UPA UPGA entfernen Powerbox S Event...

Страница 5: ...ung ber die ent sprechenden Annahmestellen zu Abfall Entsorgungsgesetz 1 Trennen Sie die Komponenten nach Material gruppen 2 Entsorgen Sie Verpackungsmaterialen Kar ton F llmaterialien Kunststoffe ber...

Страница 6: ...cluding con necting cable 2 plastic locking pins and these in stallation instructions 3 Intended use Electric PTC supplementary heat register for WS 75 Powerbox S and H ventilation units with heat rec...

Страница 7: ...ctronics com partment 3 EPP sealing plugs 2 Remove the cover of electronics compartment 2 screws 3 Remove both of the upper EPP sealing plugs Guide the connecting cable in 3 steps into the electronics...

Страница 8: ...ir fan starts When functioning correctly heated air flows out of the supply air opening Set Supply air heat register parameter to off 8 Replacing PTC heat register 1 Powerbox H Remove WS 75 APA UPA UP...

Страница 9: ...d recycle them at the ap propriate collection points Waste Management Act 1 Separate the components according to mater ial groups 2 Dispose of packaging materials cardboard filling materials plastics...

Страница 10: ...2 goupilles de s ret en plastique et cette notice d installation 3 Utilisation conforme Registre de r chauffage lectrique PTC pour ap pareils de ventilation r cup ration de chaleur WS 75 Powerbox S et...

Страница 11: ...r le cache de protection existant 1 Couvercle du bo tier 1 1 Vis couvercle du bo tier 10 unit s 2 Compartiment lectronique avec platine principale A1 2 1 Vis de fixation compartiment lectro nique 3 Bo...

Страница 12: ...istance entre le trou dans le plastique EPP et la platine pos e WS 75 NH 120 mm 6 Ins rer le module de registre de chauffage PTC dans les fentes du bo tier et fixer avec les deux goupilles de s ret en...

Страница 13: ...uffage PTC ou aux pi ces de bo tier chaudes Ne toucher le registre de chauffage ou les pi ces de bo tier que s ils sont refroidis 4 D brancher le c ble du registre de chauffage PTC et sortir le c ble...

Страница 14: ...Verdrahtungsplan Wiring diagram Schema de c blage 14 Verdrahtungsplan Wiring diagram Schema de c blage...

Страница 15: ...Notizen...

Страница 16: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Deutschland Service 49 7720 6940 info maico de 0185 1272 0000_RLF 9_11 21_DSW...

Отзывы: