Description of unit | ACX2180 | 14
en
5.5
Functional description
The refrigerant recovered from the air conditioning system
pass through the combo filter to remove suspended
particles and moisture.
The purpose of the vacuum pump is to generate a vacuum
in the air conditioning system which removes excess
moisture and to detect possible leaks in the vehicle air
conditioning system.
Used oil is separated from the recovered vehicle refrigerant
and drained into the used oil bottle.
The vehicle air conditioning system is partly filled with UV
dye to facilitate the detection of leaks in the event of
damage to the vehicle air conditioning system.
The refrigerant in the internal refrigerant bottle is used
for filling the vehicle air conditioning system.
The purging unit for the non-condensable gases, consisting
of a temperature sensor, pressure sensor, coil and orifice
always takes effect when the internal refrigerant bottle
pressure is higher than the saturation pressure
Содержание ArcticPRO ACX2180