A/C System Service | ACX2180 | 20
en
9.3
Recovery
process
1.
From the main menu, select MANUAL, and then deselect
all options except for RECOVERY.
2.
To change the service hose, touch the blue box at the
bottom of the screen that says LP-HP. A menu will pop up
that allows technician to select which hoses to perform
service through.
3.
Press green arrow in lower right corner to begin service.
4.
Follow on screen instructions to begin recovery process.
If no pressure is detected in the system, this function will not
start. Technician should ensure couplers are open. If the
system is empty, operator must exit and select a vacuum
process.
There is potential for unit to display an error during this service
for high internal pressure. This can occur due to high operating
temperatures or hot refrigerant gasses entering the ACX2180
9.4
Vacuum process
1
From the main menu, select MANUAL, and then deselect
all options except for VACUUM.
2
To change the service hose, touch the blue box at the
bottom of the screen that says LP-HP. A menu will pop up
that allows technician to select which hoses to perform
service through.
3
To adjust vacuum time, touch in the VACUUM TIME box.
The screen in Figure below will appear.
Fig. 17: Vacuum time adjustment
4
Swipe finger up or down to adjust the hours and minutes,
then press the
to accept or the X to cancel time
adjustment.
5
If the vacuum test time needs adjusted, touch in the TEST
TIME box.
6
Press green arrow in lower right corner to begin service.
7
Follow on screen instructions to begin vacuum process
9.5
Charge process
1.
From the main menu, select MANUAL, and then deselect all
options except for CHARGE.
2.
To change the service hose, touch the blue box at the bottom of
the screen that says LP-HP. A menu will pop up that allows
technician to select which hoses to perform service through.
3.
To adjust Charge amount, touch in the REFRIGERANT AMOUNT
box. The screen in Figure below will appear.
Fig. 18: Charge amount adjustment
4.
Swipe finger up or down to adjust the refrigerant value to the
vehicle manufacturer’s recommended value, then press the
to
accept or the X to cancel time adjustment.
5.
Then click the Oil amount box to adjust oil amount and type.
Fig. 19: Oil amount adjustment
6.
Swipe finger up or down to adjust the oil values, then press the
to accept or the X to cancel oil value adjustments.
7.
If desired, turn the Tracer injection on to inject UV Dye into the
vehicle A/C system.
8.
Press the green arrow in lower right corner to begin service.
9.
Follow on screen instructions to complete charge process.