DIAGNOSTIC MANUAL
MAN-00152
EMS
OCT 2011/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2011 Mahindra & Mahindra Ltd.
144
P268F - Cylinder 4 injector adjustment code incorrect error
IQA MONITORING
IQA monitoring monitors the missing or faulty programming of IQA values
COMPONENT LOCATION
NORMAL
OPERATION
During ignition ON , the ECU monitors the checksum of cylinder 2 IQA code
and is within the range
DTC DETECTING
CONDITION
No IQA code read by EEPROM
The checksum of IQA code is not correct
PROBABLE
CAUSES
IQA code not written
Faulty EMS ECU
LAMP STATUS
System Check lamp ON
DTC REACTION
Cylinder 4 injector adjustment will not happen
HEALING
CONDITION
Ignition OFF/ON