6.5
Mechanical Inspection
1 Check that the base surfaces of the light tester and the laser tripod are even.
2 Mount the laser calibration set on the tripod and position it opposite the MLT:
insert laser mount with the battery housing (B) into prism (A).
3 Move the laser and prism to position 1 (right endpoint). The prism with the
laser is held in the correct position by the magnet.
4 Check the vertical alignment of the MLT. Apply the spirit level to the lens and
read it.
5 Use adjustment screws (C) and a circle spirit level (D) to align the base plate
so that the laser is horizontal.
6 Check that the lens is aligned parallel to the rail by measuring the distance
between the alignment rail (F) and the lens at two points.
7 Switch on the laser. The laser beam should hit the centre of the Fresnel lens.
2