1.0 INTRODUCTION
The 5211 is a 0-1A current-regulated 24 VDC power supply and display that is designed for
use with Magtrol’s Hysteresis Brakes and Clutches. It features a 10-turn current adjustment
potentiometer and 3 selectable current ranges: 200 mA, 500 mA, and 1 000 mA. A convenient
built-in panel meter displays the braking current being applied.
The 5211 is designed as a closed-loop power supply to provide smooth application of
current throughout an entire range up to a maximum set point. By utilizing regulated current,
fluctuations in brake torque caused by temperature changes within the brake coil are
eliminated. Braking current can be controlled manually from the front panel using the 10-turn
potentiometer. Alternatively, if remote operation is required, the 5211 can be controlled by
an external source using the 0-5 VDC control input located on the rear panel.
1.1
S
PECIFICATIONS
Brake Voltage
24 VDC
CURRENT RANGES:
Low Scale
Medium Scale
High Scale
0 to 200 mA
0 to 500 mA
0 to 1 000 mA
Current Regulation
± 1% Full Scale
Braking Control
10-turn potentiometer (front panel) or
0–5 VDC external control (back panel)
Brake Fuse
(5 × 20 mm) IEC 1.25 A 250 V T
Line Fuse
(5 × 20 mm)
5211-2 120 V:
IEC
1.0 A 250 V T
5211-2A 240 V:
IEC
0.4 A 250 V T
Power Requirements
70 VA
Voltage Requirements
120/240 V AC 50/60 Hz
External Control
Impedance
1 M Ohms