Section 2. Communications
19
Label
Property
ID
P-
Value
Description
Default
0x1E
P30
Pre card string
0 (0x00)
0x1F
P31
Post card string
0 (0x00)
0x20
P32
Pre track string
0 (0x00)
0x21
P33
Post track string
0 (0x00)
0x22
P34
Terminating string
C/R (0x0D)
0x23
P35
Programmable field separator (this key is never
found in track data or the default programmable
field separators)
“|” (0x7C)
Tk1 SS
0x24
P36
ISO/ABA start sentinel
“%” (0x25)
Tk2-SS
0x25
P37
ISO/ABA 5-bit start sentinel
“;” (0x3B)
Tk3-SS
0x26
P38
ISO/ABA start sentinel
“+” (0x2B)
Tk3-SS
AAMVA
0x27
P39
AAMVA start sentinel
“#” (0x23)
Tk2-SS 7 bit
0x28
P40
7 bit start sentinel (ISO/ABA Track 1 start sentinel)
“@”(0x40)
Tk3-SS 7 bit
0x29
P41
7 bit start sentinel (ISO/ABA Track 1 start sentinel)
“&”(0x26)
ES
0x2B
0x2D
0x2E
0x2F
P43
P45
P46
P47
End Sentinel
Track 1 Specific End Sentinel
Track 2 Specific End Sentinel
Track 3 Specific End Sentinel
“?” (0x3F)
“?” (0x3F)
“?” (0x3F)
“?” (0x3F)
Track 1, Track 2 and Track 3 Encrypted Data includes the Start and End Sentinel that were
decoded from the card.
All fields with the format P# are programmable configuration property numbers. They are
described in detail later in this document.
Reader Encryption Status
This two byte Binary field contains the Encryption Status. The Reader Encryption Status is sent
in big endian byte order. Byte 1 is the least significant byte. Byte 1 LSB is status bit 0. Byte 2
MSB is status bit 15. The Reader Encryption Status is defined as follows:
Bit 0
= DUKPT Keys exhausted
Bit 1
= Initial DUKPT key Injected, always set to One
Bit 2
= Encryption Enabled, always set to One
Bit 3
= Authentication Required
Bit 4
= Timed Out waiting for user to swipe card
Bit 5
= Encrypting IntelliHead Communication Error – Message too Short
Bit 6
= Encrypting IntelliHead Communication Error – Wrong Message Type
Bit 7
= Key Synchronization Error (only on units equipped with Encrypting
IntelliHead)
Bit 8
= Encryption Counter Expired
Bits 9–15 = Unassigned (always set to Zero)