Appendix H - EMV Settings (EMV Only)
DynaPro Go| Handheld PIN Pad Device with MSR/Contact/Contactless | Programmer’s Manual (COMMANDS)
Page 227 of 247 (
D998200136-31
)
H.6.2
D-PAS Application Settings
There are 5 D-PAS Application Slots. Only 2 have factory defaults programmed.
Table 4-158 - D-PAS Application Settings Slot 0
Tag Description
Tag
Configurable
Default Value (Hex)
Application DF Name
84
MagTek
A0000001523010
Acquirer ID - Application 9F01
MagTek
000000000001
Application AID
9F06
MagTek
A0000001523010
Application Version
9F09
MagTek
0100
Application Floor Limit
9F1B
MagTek
00003A98
Reader Contactless
Transaction Limit
DF00
MagTek
000000030000
Reader Contactless CVM
Limit
DF01
MagTek
000000002000
Reader Contactless Floor
Limit
DF02
MagTek
000000015000
Terminal Action Code -
Default
DF8120
MagTek
0000000000
Terminal Action Code -
Denial
DF8121
MagTek
0000000000
Terminal Action Code -
Online
DF8122
MagTek
0000000000
ASI (Application Select
Indicator)
DFDF23
MagTek
01
Table 4-159 - D-PAS Application Settings Slot 1
Tag Description
Tag
Configurable
Default Value (Hex)
Application DF Name
84
MagTek
A0000003241010
Acquirer ID - Application 9F01
MagTek
000000000001
Application AID
9F06
MagTek
A0000003241010
Application Version
9F09
MagTek
0100
Application Floor Limit
9F1B
MagTek
00003A98
Reader Contactless
Transaction Limit
DF00
MagTek
000000030000
Reader Contactless CVM
Limit
DF01
MagTek
000000002000
Reader Contactless Floor
Limit
DF02
MagTek
000000015000