background image

Magrini Limited
Unit 5, Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG
Tel: 01543 375311   Fax: 01543 361172   Email: [email protected]   Web: www.magrini.co.uk

Magrini Limited
Unit 5, Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG
Tel: 01543 375311   Fax: 01543 361172   Email: [email protected]   Web: www.magrini.co.uk

INSTRUCTIONS FOR USE

Magrini Baby Changing Unit - Model MC75

Doc: MC7503  Date: February 2014

INSTRUCTIONS FOR USE

Magrini Baby Changing Unit - Model MC75

IMPORTANT: RETAIN FOR FUTURE REFERENCE. READ CAREFULLY.

This changing unit must be fixed to the wall for safe use of the product and the fastenings used
should be appropriate to the wall.
To assure proper installation, we suggest that a qualified person install this unit. 
Magrini Ltd., will not be responsible if the changing station is not installed correctly. 
All recommended fixings are supplied. Replacements are available free of charge from Magrini -
do not use less substantial fittings.
We  DO  NOT  recommend  fixing  onto  toilet  or  changing  room  cavity  walls,  unless  specific
studwork is in place. If in doubt contact the Magrini sales office.
PLEASE NOTE: this unit does not require a changing pad and therefore, no pad is supplied with 
this unit.

Tools required:

Drill

10mm Masonry Drill Bit

For fixing into blockwork or brickwork:

1) Using the template supplied, mark the position of the holes to be drilled ensuring that the correct height of 

79cm from the floor to the bottom of the template is correct. Check for correct level. Drill the 2 top holes and
2 middle holes, fit the plastic block fixings (supplied). Use four M8x70 turbo coach screws into the top four 
block fixings.

2) Screw into block fixings and allow 10mm protruding. Test fit unit for level and verify correct position of mark

for bottom two holes. Remove unit and drill bottom two holes and fit the plastic block fittings. Tighten top 
four screws until approximately 4mm protruding. Fit unit over screws and push down to lock into slots.

3) Use the remaining two M8x70 turbo coach screws. Screw into the bottom two holes of the unit and into the 

block fixings and tighten.

4) Pull unit open and close several times to check for correct movement.

Note: All assembly fittings shall always be correctly tightened and checked regularly. Screws shall not be 

loose because a child can squeeze parts of the body, or clothing (e.g. strings, necklaces, ribbons for 
babies, dummies, etc.) could get caught. There would be danger of strangulation.
Units should be fitted no less than 100mm from the corner of the room to enable access for cleaning.
Be aware of the risk of open fire and other sources of strong heat, such as electric bar fires, gas fires etc. 
in the near vicinity of the unit.

6 No. Fixing Plugs 
10mm x 60mm

Cleaning Instructions

The nappy changing unit may be washed and wiped with a damp soft cloth or sponge. Use of mild
detergent and warm water will remove the majority of dust and stains. For more obstinate stains a
domestic cream cleaner can be used. Do not use any
abrasive cloths, caustic or solvent cleaners as these may
damage the unit.

Maintenance Instructions

Check that the unit is securely fixed to the wall.
Check  that  the  changing  bed  does  not
rest  below  the  horizontal  position.
Ensure warning label is in place on the
inside  of  the  unit  and  general
cleanliness is within given guidelines.
Ensure closing mechanism returns the
tray  to  the  upright  position.  Any
replacement parts must be obtained
from Magrini only.

WARNING: DO NOT LEAVE THE CHILD UNATTENDED.

Intended for use for children up to a maximum weight of 15kg.

Do not use the changing unit when any part is broken, torn or missing.

Changing Unit Fixing Parts (supplied):

6 No. Turbo Coach Screws M8 x 70
Hexagon Head, C-1022 Steel/Zinc Plated
Yellow Passivated

10mm Hex Socket or Spanner 

Spirit Level

TEMPLATE

SUPPLIED

Drill

(10mm Masonry Bit)

Drill

(10mm Masonry Bit)

79cm (31”)

79cm (31”)

Floor Level

Magrini Limited
Unit 5, Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG
Tel: 01543 375311   Fax: 01543 361172   Email: [email protected]   Web: www.magrini.co.uk

Magrini Limited
Unit 5, Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG
Tel: 01543 375311   Fax: 01543 361172   Email: [email protected]   Web: www.magrini.co.uk

INSTRUCTIONS FOR USE

Magrini Baby Changing Unit - Model MC75

Doc: MC7503  Date: February 2014

INSTRUCTIONS FOR USE

Magrini Baby Changing Unit - Model MC75

IMPORTANT: RETAIN FOR FUTURE REFERENCE. READ CAREFULLY.

This changing unit must be fixed to the wall for safe use of the product and the fastenings used
should be appropriate to the wall.
To assure proper installation, we suggest that a qualified person install this unit. 
Magrini Ltd., will not be responsible if the changing station is not installed correctly. 
All recommended fixings are supplied. Replacements are available free of charge from Magrini -
do not use less substantial fittings.
We  DO  NOT  recommend  fixing  onto  toilet  or  changing  room  cavity  walls,  unless  specific
studwork is in place. If in doubt contact the Magrini sales office.
PLEASE NOTE: this unit does not require a changing pad and therefore, no pad is supplied with 
this unit.

Tools required:

Drill

10mm Masonry Drill Bit

For fixing into blockwork or brickwork:

1) Using the template supplied, mark the position of the holes to be drilled ensuring that the correct height of 

79cm from the floor to the bottom of the template is correct. Check for correct level. Drill the 2 top holes and
2 middle holes, fit the plastic block fixings (supplied). Use four M8x70 turbo coach screws into the top four 
block fixings.

2) Screw into block fixings and allow 10mm protruding. Test fit unit for level and verify correct position of mark

for bottom two holes. Remove unit and drill bottom two holes and fit the plastic block fittings. Tighten top 
four screws until approximately 4mm protruding. Fit unit over screws and push down to lock into slots.

3) Use the remaining two M8x70 turbo coach screws. Screw into the bottom two holes of the unit and into the 

block fixings and tighten.

4) Pull unit open and close several times to check for correct movement.

Note: All assembly fittings shall always be correctly tightened and checked regularly. Screws shall not be 

loose because a child can squeeze parts of the body, or clothing (e.g. strings, necklaces, ribbons for 
babies, dummies, etc.) could get caught. There would be danger of strangulation.
Units should be fitted no less than 100mm from the corner of the room to enable access for cleaning.
Be aware of the risk of open fire and other sources of strong heat, such as electric bar fires, gas fires etc. 
in the near vicinity of the unit.

6 No. Fixing Plugs 
10mm x 60mm

Cleaning Instructions

The nappy changing unit may be washed and wiped with a damp soft cloth or sponge. Use of mild
detergent and warm water will remove the majority of dust and stains. For more obstinate stains a
domestic cream cleaner can be used. Do not use any
abrasive cloths, caustic or solvent cleaners as these may
damage the unit.

Maintenance Instructions

Check that the unit is securely fixed to the wall.
Check  that  the  changing  bed  does  not
rest  below  the  horizontal  position.
Ensure warning label is in place on the
inside  of  the  unit  and  general
cleanliness is within given guidelines.
Ensure closing mechanism returns the
tray  to  the  upright  position.  Any
replacement parts must be obtained
from Magrini only.

WARNING: DO NOT LEAVE THE CHILD UNATTENDED.

Intended for use for children up to a maximum weight of 15kg.

Do not use the changing unit when any part is broken, torn or missing.

Changing Unit Fixing Parts (supplied):

6 No. Turbo Coach Screws M8 x 70
Hexagon Head, C-1022 Steel/Zinc Plated
Yellow Passivated

10mm Hex Socket or Spanner 

Spirit Level

TEMPLATE

SUPPLIED

Drill

(10mm Masonry Bit)

Drill

(10mm Masonry Bit)

79cm (31”)

79cm (31”)

Floor Level

INSTRUCTIONS FOR USE

 

Magrini Baby Change Unit - Model MC75

INSTRUCTIONS FOR USE

 

Magrini Baby Change Unit - Model MC75

Magrini Limited, Unit 5 Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG

t

: 01543 375311  •  

e

: [email protected] 

 

  

w

: www.magrini.co.uk

Doc: MC7504  Date: August 2017

Magrini Limited, Unit 5 Maybrook Industrial Estate, Brownhills, Walsall WS8 7DG

t

: 01543 375311  •  

e

: [email protected] 

 

  

w

: www.magrini.co.uk

For fixing into blockwork or brickwork:

1) Using the template supplied, mark the position of the holes to be drilled ensuring that the correct height of  
  79cm from the floor to the bottom of the template is correct. Check for correct level. Drill the 2 top holes  
  and 2 middle holes, fit the plastic block fixings (supplied). Use four M8x70 turbo coach screws into the top  
  four block fixings.
2) Screw into block fixings and allow 10mm protruding. Test fit unit for level and verify correct position of  
  mark for bottom two holes. Remove unit and drill bottom two holes and fit the plastic block fittings. Tighten  
  top four screws until approximately 4mm protruding. Fit unit over screws and push down to lock into slots.
3) Use the remaining two M8x70 turbo coach screws. Screw into the bottom two holes of the unit and into the  
  block fixings and tighten.
4) Pull unit open and close several times to check for correct movement.
Note: All assembly fittings shall always be correctly tightened and checked regularly. Screws shall not  

   

be loose because a child can squeeze parts of the body, or clothing (e.g. strings, necklaces,  

   

ribbons for babies, dummies, etc.) could get caught. There would be danger of strangulation.

   

Units should be fitted no less than 100mm from the corner of the room to enable access for  

   

cleaning. Be aware of the risk of open fire and other sources of strong heat, such as electric bar  

   

fires, gas fires etc. in the near vicinity of the unit.

Cleaning Instructions

The nappy changing unit may be washed and wiped with a damp soft cloth or sponge. Use of mild 
detergent and warm water will remove the majority of dust and stains. For more obstinate stains adomestic 
cream cleaner can be used. Do not use anyabrasive cloths, 
caustic or solvent cleaners as these maydamage the unit.

Maintenance Instructions

Check that the unit is securely fixed to the wall.
Check that the changing bed does not rest 
below the horizontal position. Ensure 
warning label is in place on the inside 
of the unit and general cleanliness is 
within given guidelines. Ensure closing 
mechanism returns the tray to the 
upright position. Any replacement parts 
must be obtained from Magrini only.

IMPORTANT: RETAIN FOR FUTURE REFERENCE. READ CAREFULLY.

This changing unit must be fixed to the wall for safe use of the product and the fastenings used 
should be appropriate to the wall.
To assure proper installation, we suggest that a qualified person install this unit. Magrini Ltd., will 
not be responsible if the changing station is not installed correctly. 
All recommended fixings are supplied. Replacements are available free of charge from Magrini - 
do not use less substantial fittings.
We DO NOT recommend fixing onto toilet or changing room cavity walls, unless specific studwork 
is in place. If in doubt contact the Magrini sales office.
PLEASE NOTE: this unit does not require a changing pad and therefore, no pad is supplied with 
this unit.

6 No. Turbo Coach Screws M8 x 70 Hexagon Head, 
C-1022 Steel/Zinc Plated Yellow Passivated

6 No. Fixing Plugs 
10mm x 60mm

Changing Unit Fixing Parts (supplied):

 

WARNING: DO NOT LEAVE THE CHILD UNATTENDED.

Intended for use for children up to a maximum weight of 15kg.
Do not use the changing unit when any part is broken, torn or missing.

Tools required:

• Drill  

• 10mm Hex Socket or Spanner 

•10mm Masonry Drill Bit   • Spirit Level

Отзывы: