Magnum Ruutu L 6.0kW Скачать руководство пользователя страница 1

 

 

 

Operating instructions 

 

Magnum Ruutu L 6.0kW - 6.6kW - 9.0kW - 10.5kW 
 
Magnum Ruutu C 6.0kW - 9.0kW 
 
Magnum Klubi 6.0kW - 9.0kW 

Содержание Ruutu L 6.0kW

Страница 1: ...Operating instructions Magnum Ruutu L 6 0kW 6 6kW 9 0kW 10 5kW Magnum Ruutu C 6 0kW 9 0kW Magnum Klubi 6 0kW 9 0kW...

Страница 2: ...ully before first using the sauna stove The instructions contain full operating and maintenance instructions installation instructions a troubleshooting guide and the warranty terms for the sauna stov...

Страница 3: ...stallation stages 9 3 2 Thermostat sensor 13 3 3 Finlandia control panel 14 Surface Installation 14 Recessed mount 15 4 Installation illustrations and renderings 16 4 1 Thermostat and controller Insta...

Страница 4: ...auna stove immediately 2 Menu button by pressing this you can move through the menus of the device as follows Default mode Target temperature Heating time Timer Default mode 3 button This button is us...

Страница 5: ...t value Please note Target temperature adjustment 40 110 C 1 C 60 C Heating time 1 h 6 h 0 5 h 1 h See Section 2 3 Timer 0 5 24 h 0 5 h 0 h Not in use 2 2 TARGET TEMPERATURE The sauna s target tempera...

Страница 6: ...ent is 0 5 h If this value is zero the timer is not in use This setting can only be changed when the device is off 2 5 TURNING THE SAUNA OFF Turn the sauna stove s power on using the control switch at...

Страница 7: ...water on the sauna stove The use of seawater is forbidden Do not throw water on the sauna stove if there are people next to it as the water splashing from the sauna stove and the steam it creates are...

Страница 8: ...electrical installation work may only be performed by an electrician qualified for the job in accordance with applicable regulations The sauna stove is connected to the power grid semi permanently wi...

Страница 9: ...est cable gland and connect the wires on the circuit board on the terminal block with the numbers 1 8 The terminal block can be detached from the main board for easier installation The terminal block...

Страница 10: ...Technical Support Pistotie 4 358405455625 from 8 16 15860 Hollola Finland info magnumkiuas fi The wire order on the board from right to left 1 Blue 2 White 3 Red 4 Yellow PLEASE NOTE If the wire needs...

Страница 11: ...viewed from the bottom of the sauna stove 8 Temperature reduction Connector J5 the lower connector on the photo above If this feature is in use it is possible to connect a relay or contactor coil to...

Страница 12: ...e other end of the supply cable to the electrical box Please note that the maximum height of the junction box is 400 mm 13 Put the control switch into position I 14 Test resistor functionality by turn...

Страница 13: ...that the distance between the ceiling and the upper edge of the sensor is 100 mm The sensor must be located 500 1000 mm from the upper edge of the sauna stove Furthermore the sensor must be located a...

Страница 14: ...e to the washroom The ingress protection of the Finlandia panel is IPX4 The standard length of the control panel s wire is 10 metres SURFACE INSTALLATION In the sauna Install the surface box at a max...

Страница 15: ...height restrictions but the recommended height is 1500mm or at the same height as the light switches When installing on a tiled surface recessed mounting has to be taken into consideration already dur...

Страница 16: ...tat from the outer edge of the sauna stove is 500 1000 mm PAY ATTENTION TO THE INCOMING AIR VALVE If incoming air cannot be directed away from the thermostat the valve may not be installed less than 1...

Страница 17: ...405455625 from 8 16 15860 Hollola Finland info magnumkiuas fi 4 2 MECHANICAL VENTILATION It is recommended that incoming air is directed straight on top of the sauna stove so that fresh air can be dis...

Страница 18: ...al ventilation the supply air should be either on the floor or low on the wall next to the sauna stove The exhaust air can be on the wall or on the ceiling The outlet valve should be closed during a s...

Страница 19: ...stove have been rendered in different colours and transparent to make the instructions clearer 4 4 1 STONE PILING STAGES RUUTU L 1 Make sure the stones are not tumbled on the sauna stove bottom Do no...

Страница 20: ...ght and prevent them from moving as the stones sink If necessary install the sauna stove s wall brackets in accordance with SECTION 4 5 5 Finish piling stones in the sauna stove The stones on the top...

Страница 21: ...the sauna stove wall before attaching to the wall The bracket is placed in the square hole on the sauna stove 2 Bend the brackets if necessary PLEASE NOTE if you are bending the brackets by hand use p...

Страница 22: ...ION OF SAFETY DISTANCES Safety distances to flammable structures Safety distance Below A Safety distance Above B Safety distance to the ceiling C Safety distance downwards maximum height D Magnum Ruut...

Страница 23: ...Diameter of the lower part A 320 mm 320 mm 320 mm 320 mm Diameter of the upper part B 324 mm 324 mm 324 mm 324 mm Height of the lower part C 730 mm 700 mm 700 mm 700 mm Height of the upper part D 200...

Страница 24: ...una dimensions 5 9 m3 5 9 m3 Sauna min height 1800 mm 2000 mm Fuse 3x10 A 3x10 A Connection cable 5x1 5 mm2 5x1 5 mm2 Weight without stones 13kg 14kg Stone amount approx 100kg approx 130kg Klubi 6 0 K...

Страница 25: ...manufacturer may charge for possible spare parts if a warranty term has been breached When troubleshooting for issues outside the scope of the manual the buyer should inquire the manufacturer about po...

Страница 26: ...26 Magnum Kiuas Operating and installation instructions 03 04 2019 Starsauna Oy Technical Support Pistotie 4 358405455625 from 8 16 15860 Hollola Finland info magnumkiuas fi 7 CONNECTION DIAGRAM...

Страница 27: ...to re pile the stones at least once a year replacing any cracked stones with new ones and washing the dust off the old usable stones If you have a sauna every day it is advisable to re pile the stones...

Страница 28: ...e error situation has been resolved E g when the sensor short circuit has been dealt with or if the device has cooled sufficiently after overheating After that you can try to switch the device on agai...

Страница 29: ...Copyright Starsauna Oy We reserve the right to make changes Starsauna OY Pistotie 4 15860 Hollola Finland info magnumkiuas fi www tahtisaunat fi...

Отзывы: